| SPECIFICATIONS |
Weight | 2.6 lb/1.18 kg |
Length | 5 1/8 in/130 mm |
Width | 2 in/51 mm |
Pressure | 10,000 psi/690 bar |
Porting | 1/4 in. Female NPT |
HYDRAULIC SYSTEM REQUIREMENTS
The RV06 Rocker Valve hydraulic system requirements are determined by the hydraulic pressure rating of the tool being controlled by the RV06. The following general rules apply when choosing a tool to match up with the RV06.
•Whenever possible, Stanley Hydraulic Tools recommends that you use the Stanley IP16 Intensapress intensi- fier to power the RV06 and tools attached to it.
•Make sure the compression tool, cutter, or lifting device attached to the rocker valve is capable of operation at 10,000 psi/690 bar.
•If the operating pressure of the compression tool, cutter, or lifting device attached to the rocker valve is below
10,000 psi/690 bar, DO NOT USE IT with an intensifier or hydraulic supply adjusted to deliver 10,000 psi/690 bar.
•The intensifier used to power the rocker valve can usually be adjusted for lower operating pressures. This work should only be performed by a qualified hydraulic technician.
•If the intensifier pressure cannot be lowered to match the tool you are using, you must either use a tool rated at the available operating pressure or utilize an intensifier with the correct output pressure.
•If you are in doubt about the tool or intensifier you intend to use with the RV06, please contact Stanley Hydraulic
Tools for assistance.
14 ► RV06 User Manual