Siemens FC700A manual Modifying the impedance of the various C-Bus cables

Page 3

1

About this document

6

2

Safety regulations

8

2.1

Signal words and symbols

8

2.1.1

Signal words and their meaning

8

2.1.2

Symbols and their meaning

8

2.1.3

Classification and meaning of additional symbols

9

2.2

Safety-relevant working instructions

9

3

Main features

11

4

Technical data FC700A

12

5

Logical and physical structure

13

6

Bus systems

14

6.1

Bus overview

15

6.2

Modifying the impedance of the various C-Bus cables

15

6.2.1

Diagram

16

7

C-Bus stations

17

7.1

Station

17

7.2

Types of stations

17

7.3

Hardware

17

7.4

Visualizer for Windows remote operation software (not available yet) ...

18

7.5

Logical AREAS

19

8

Limitations of C-Bus participants

20

8.1

Main CPU limits

20

8.1.1

Maximum number of devices

20

8.1.2

Limits in the logical structure

20

8.1.3

Maximum number of criteria in zones control 4 and 6

20

8.1.4

Maximum number of ZONE time channel

20

8.1.5

Maximum number of I-Bus-modules

21

8.1.6

Limits of 5V supply

21

8.2

Control terminal limits (FC/FT)

21

8.2.1

Limitation of visible texts on a FC700A

21

8.2.2

Limitation of visible texts on a FT700A

21

8.3

Gateway limits (FG)

22

9

Specify hardware required

23

10

Control unit FC700A

24

10.1

Configuration

24

10.2

Block diagram

25

10.3

Modules

25

11

Auxiliary power supply

26

11.1

Configuration

26

11.2

Block diagram

26

11.3

Modules

26

12

Control terminal B3Q700 (FC/FT)

27

12.1

Features

27

12.2

Options

27

12.2.1

Plexiglas door to B3Q700 (FC/FT)

27

12.2.2

Place of the E3I020 RS232 module (FT)

28

12.2.3

Place of the E3I040 LON interface (FT)

28

 

 

3

Siemens Building Technologies

007836_a_en_--.doc

Fire & Security Products

03.2004

Image 3
Contents Planning Page Modifying the impedance of the various C-Bus cables 12.3 21.1 About this document Place Signification ConventionsDocument identification Modification indexSymbols and their meaning Safety regulationsSignal words and symbols Signal words and their meaningAssembly, installation, commissioning and inspection work Safety-relevant working instructionsClassification and meaning of additional symbols Electrical installationsTesting the product operability Modifications to the system design and the productModules and spare parts Stations Main featuresTechnical data FC700A Physical structure Logical and physical structureLogical structure LinkingLON-Bus Bus systemsBus SynoLOOP and SynoLINE600Bus overview Modifying the impedance of the various C-Bus cablesRd = Ri x 3,65 45Ω Ri 200Ω Ri Ohm DiagramHardware Bus stationsStation Types of stationsBUS Logical Areas Main CPU limits Limitations of C-Bus participantsLimitation of visible texts on a FC700A Control terminal limits FC/FTMaximum number of I-Bus-modules Limits of 5V supplyGateway limits FG Specify hardware required Control unit FC700A ConfigurationBlock diagram ModulesFC700A Component Order-No Description Auxiliary power supplyPlexiglas door to B3Q700 FC/FT FeaturesControl terminal B3Q700 FC/FT OptionsPlace of the E3I040 LON interface FT Place of the E3I020 RS232 module FTInstallation possibilities FT EN54 requirements Power supplyControl unit FC700A Loop C-Bus12.7 Modules H23G230 H26G220 H28G200 Range of cabinets H23 / H26 / H28Recessed mounting H23G230 and H28G200 H23U220 H23U230 H23G230 H23Z230H28Z010 H28G200 14 19 accessories Input/output modules Special featuresLine modules OverviewRoom Detection line addressable SynoLOOPSynoLINE600-Ex Detection line collective SynoLINE600/-ExAddressable detection line Connection factors, line resistances and capacitan- cesTerminology and abbreviations Collective detection lineMax. C Max. R Line resistance and capacitanceOverview of the available modules with control outputs Control modulesApplication of control modules Means of linkingControl outputs remote station type FT700A Control outputs station type FC700AAll-AREAsingle-AREA CPU-overlapping controlsMimic Display panel outputs K3R072Z3I530 F12A470 Relay outputsK3G060 F12A100LON-Bus as stub line LON-Bus devicesLON-Bus as free topology 18.4 LON/Mimic Display p.c.b K3I050LON I/O card K3I110 H23G230 B3Q580 Indicator devices B3Q580 and B3Q590/595Main features GatewayApplication Modules Remote transmission Remote transmission deviceInterfacing Printer interface Application variant FTApplication variant FC Concept Power supplyPower supply for the control unit Auxiliary power supply24V / 0,63A Operation with power supply from control unitEmergency power supply Specifying battery capacityCapacity values for standard configurations Quiescent current table Alarm concept Cerberus Alarm Concept CACPrinciple of the Cerberus alarm concept Organization of system operation Determine the alarm organizationCommissioning Functions Parameterization, Flash programming27 FC700A modules in alphabetical order FC700A modules in alphabetical order EOL22 Spare partsB3Q580/590/595, B3R051 Configuration sheetsList of configuration sheets Auxiliary power supplyCable, terminals, relay Z1K030 Inscription setsView a Control terminal FT Control terminal FT700ADisplay & operating terminals Details see .7 / 17.9 Externally placed modulesPage 007836aen

FC700A specifications

The Siemens FC700A is a cutting-edge frequency converter designed to optimize drive efficiency and enhance the performance of various applications in industrial settings. Its robust build and advanced technology make it suitable for a range of automation and control tasks, particularly in industries such as manufacturing, water treatment, and material handling.

One of the main features of the FC700A is its high-performance motor control capability. The converter supports both sensorless vector control and direct torque control, allowing for precise speed regulation and enhanced torque management. This level of control is essential for applications requiring high responsiveness and accuracy, such as conveyor systems and pumps.

Additionally, the Siemens FC700A incorporates advanced communication technologies, making it highly compatible with various automation systems. It supports multiple communication protocols, including PROFINET, EtherNet/IP, and Modbus, ensuring seamless integration into existing industrial networks. This versatility simplifies the process of connecting to different types of devices and enhances overall system reliability.

Another notable characteristic of the FC700A is its energy efficiency. Designed with the latest eco-friendly technologies, the frequency converter minimizes energy consumption, reducing operational costs and environmental impact. The built-in energy-saving features, such as automatic load detection and adaptive speed control, work together to ensure optimal performance while promoting sustainability.

The FC700A also boasts an intuitive user interface, making installation and configuration straightforward. Its graphical display provides real-time monitoring of drive parameters, allowing operators to quickly assess the status of their systems. The streamlined setup process reduces downtime and facilitates maintenance routines, ensuring uninterrupted production processes.

Furthermore, the frequency converter is built to withstand harsh industrial environments. Its robust housing protects it from dust, moisture, and temperature variations, making it a reliable choice for applications in challenging conditions. The FC700A is equipped with advanced thermal management systems that ensure stable operation even under high load conditions.

In summary, the Siemens FC700A is a versatile and efficient frequency converter that excels in performance, connectivity, and robustness. With its advanced control technologies, energy-saving features, and user-friendly interface, it is an ideal solution for modern industrial applications, promoting enhanced productivity and operational excellence.