Siemens FC700A manual Specify hardware required

Page 23

Specify hardware required

9 Specify hardware required

In order to be able to specify the hardware required, system key data must be specified according the following procedure:

1.Specify number and type of detection lines Dependent on:

Detector series

Number of detectors, input and output modules

Building structure

2.Specify number and type of fire control installations Dependent on:

The fire protection installations to be activated

Location of the contacts (centralized or decentralized)

Individual types of contact (250VAC/10A or 30VDC/1A)

3.Specify number of operating units

Dependent on:

Operating concept

Parallel indicator panels, fire department control panels

4.Specify Accessories required

Dependent on:

Printer interface and printer

Remote transmission equipment

Gateway, etc.

5.Specify emergency power supply battery capacity Dependent on:

Total quiescent current

Required emergency current operating period (according to country)

Type of remote transmission

6.Provide configuration sheet/sheets (see chapter 29)

Dependent on:

Select sheets corresponding to the configuration

Complete everything

 

23

 

 

Siemens Building Technologies

007836_a_en_--.doc

Fire & Security Products

03.2004

Image 23
Contents Planning Page Modifying the impedance of the various C-Bus cables 12.3 21.1 About this document Place Signification ConventionsDocument identification Modification indexSymbols and their meaning Safety regulationsSignal words and symbols Signal words and their meaningAssembly, installation, commissioning and inspection work Safety-relevant working instructionsClassification and meaning of additional symbols Electrical installationsModules and spare parts Testing the product operabilityModifications to the system design and the product Stations Main featuresTechnical data FC700A Physical structure Logical and physical structureLogical structure LinkingLON-Bus Bus systemsBus SynoLOOP and SynoLINE600Rd = Ri x 3,65 45Ω Ri 200Ω Bus overviewModifying the impedance of the various C-Bus cables Ri Ohm DiagramHardware Bus stationsStation Types of stationsBUS Logical Areas Main CPU limits Limitations of C-Bus participantsLimitation of visible texts on a FC700A Control terminal limits FC/FTMaximum number of I-Bus-modules Limits of 5V supplyGateway limits FG Specify hardware required Control unit FC700A ConfigurationFC700A Block diagramModules Component Order-No Description Auxiliary power supplyPlexiglas door to B3Q700 FC/FT FeaturesControl terminal B3Q700 FC/FT OptionsPlace of the E3I040 LON interface FT Place of the E3I020 RS232 module FTInstallation possibilities FT EN54 requirements Power supplyControl unit FC700A Loop C-Bus12.7 Modules H23G230 H26G220 H28G200 Range of cabinets H23 / H26 / H28H28Z010 H28G200 Recessed mounting H23G230 and H28G200H23U220 H23U230 H23G230 H23Z230 14 19 accessories Input/output modules Special featuresLine modules OverviewRoom Detection line addressable SynoLOOPSynoLINE600-Ex Detection line collective SynoLINE600/-ExAddressable detection line Connection factors, line resistances and capacitan- cesTerminology and abbreviations Collective detection lineMax. C Max. R Line resistance and capacitanceOverview of the available modules with control outputs Control modulesApplication of control modules Means of linkingControl outputs remote station type FT700A Control outputs station type FC700AAll-AREAsingle-AREA CPU-overlapping controlsZ3I530 Mimic Display panel outputsK3R072 F12A470 Relay outputsK3G060 F12A100LON-Bus as stub line LON-Bus devicesLON I/O card K3I110 LON-Bus as free topology18.4 LON/Mimic Display p.c.b K3I050 H23G230 B3Q580 Indicator devices B3Q580 and B3Q590/595Application Main featuresGateway Modules Interfacing Remote transmissionRemote transmission device Application variant FC Printer interfaceApplication variant FT Concept Power supplyPower supply for the control unit Auxiliary power supply24V / 0,63A Operation with power supply from control unitCapacity values for standard configurations Emergency power supplySpecifying battery capacity Quiescent current table Principle of the Cerberus alarm concept Alarm conceptCerberus Alarm Concept CAC Organization of system operation Determine the alarm organizationCommissioning Functions Parameterization, Flash programming27 FC700A modules in alphabetical order FC700A modules in alphabetical order EOL22 Spare partsB3Q580/590/595, B3R051 Configuration sheetsList of configuration sheets Auxiliary power supplyCable, terminals, relay Z1K030 Inscription setsView a Control terminal FT Control terminal FT700ADisplay & operating terminals Details see .7 / 17.9 Externally placed modulesPage 007836aen

FC700A specifications

The Siemens FC700A is a cutting-edge frequency converter designed to optimize drive efficiency and enhance the performance of various applications in industrial settings. Its robust build and advanced technology make it suitable for a range of automation and control tasks, particularly in industries such as manufacturing, water treatment, and material handling.

One of the main features of the FC700A is its high-performance motor control capability. The converter supports both sensorless vector control and direct torque control, allowing for precise speed regulation and enhanced torque management. This level of control is essential for applications requiring high responsiveness and accuracy, such as conveyor systems and pumps.

Additionally, the Siemens FC700A incorporates advanced communication technologies, making it highly compatible with various automation systems. It supports multiple communication protocols, including PROFINET, EtherNet/IP, and Modbus, ensuring seamless integration into existing industrial networks. This versatility simplifies the process of connecting to different types of devices and enhances overall system reliability.

Another notable characteristic of the FC700A is its energy efficiency. Designed with the latest eco-friendly technologies, the frequency converter minimizes energy consumption, reducing operational costs and environmental impact. The built-in energy-saving features, such as automatic load detection and adaptive speed control, work together to ensure optimal performance while promoting sustainability.

The FC700A also boasts an intuitive user interface, making installation and configuration straightforward. Its graphical display provides real-time monitoring of drive parameters, allowing operators to quickly assess the status of their systems. The streamlined setup process reduces downtime and facilitates maintenance routines, ensuring uninterrupted production processes.

Furthermore, the frequency converter is built to withstand harsh industrial environments. Its robust housing protects it from dust, moisture, and temperature variations, making it a reliable choice for applications in challenging conditions. The FC700A is equipped with advanced thermal management systems that ensure stable operation even under high load conditions.

In summary, the Siemens FC700A is a versatile and efficient frequency converter that excels in performance, connectivity, and robustness. With its advanced control technologies, energy-saving features, and user-friendly interface, it is an ideal solution for modern industrial applications, promoting enhanced productivity and operational excellence.