Siemens CFVA-IP user manual Technical data for IP-Module CVVA-IP

Page 10

Technical data

5.2Technical data for IP-Module CVVA-IP

Electrical supply

12 V DC/24 V AC

Power requirement

max. 6.0 W

Operating temperature range

-10 – +50 °C, max. relative humidity 90%

Storage temperature range

-20 – +60 °C, max. relative humidity 70%

Dimensions (H x Ø)

48 x 135 mm

Weight

620 g

Material

Aluminum

IP rating

IP66

System requirements

All systems, which feature TCP/IP network functions and provide an

 

http browser (Microsoft Internet Explorer from version 5.5 with Java

 

plug-in or Mozilla or Netscape from version 7.0).

Protocols

ARP, BOOTP/DHCP, TCP/IP, HTTP, ICMP, SNMP, FTP and DNS

Installation

IP address configurable via ARP, BOOTP/DHCP, connection to twisted-

 

pair RJ45 Ethernet.

Network connection

10BaseT Ethernet or 100BaseTX Fast Ethernet, auto-sensing, full/half

 

duplex

Image formats

QCIF (176x144),

 

CIF (352x288),

 

4CIF (704x576) (interlaced).

Image transmission

Motion JPEG (multipart/x-mixed-replace content type), user

 

configurable JPEG single image frame quality, streaming up to 25

 

images per second with QCIF and CIF or up to 10 images per second

 

with 4CIF.

Security

Separate passwords for image access and system configuration.

Hardware

8 MB RAM, 16 MB flash ROM

10

Siemens Building Technologies

Fire Safety & Security Products

Image 10
Contents IP-Module IP-Module CFVA-IP IP-Module CVVA-IP Page Contents Page Introduction About this manualGeneral Safety Precautions Ordering data for IP-Module CFVA-IP Ordering dataOrdering data for IP-Module CVVA-IP Norms and Directives EU DirectiveTechnical data Technical data for IP-Module CFVA-IPTechnical data for IP-Module CVVA-IP Installation and connection of the dome camera Installing the IP-ModuleInstalling IP-Module type CFVA-IP IP-Module fixingInstalling IP-Module type CVVA-IP Exploded view of IP-Module CVVA-IPIP-Module fixing Mapping a network route Establishing initial communication with the deviceChanging the IP address of the client PC Control panel Network connectionsEstablishing initial communication with the device Checking device accessibility Ping xxx.xxx.xxx.xxx xxx.xxx.xxx.xxx =Device homepage Using Internet Explorer Using the Web-Cam IP ManagerCalling up the device homepage Click on the Home page of selected device... button Components of the device homepage Device homepageConfiguring network settings Changing the device IP address Automatic address designation by the Dhcp or Bootp serverManual IP address and subnet mask allocation Changing the IP address using the Web-Cam IP Manager ExampleConfiguring network settings Configuring general image parameters Configuring image parametersConfiguring text overlay Overlay text position Configuring Jpeg encoder settingsOverlay text Overlay text colorPAL/CCIR NTSC/EIA Setting the date and time Configuring user names and passwords Factory set user namesRestarting the IP Module Manual restartActivate the Enable restart by Ping-Watchdog check box Restart by Ping WatchdogDisplaying live video Live videoDisplaying live video Low Setting live video resolutionStoring still pictures StandardStatic IP address Establishing access to the device via internetConnecting to internet Dynamic IP addressExample of access using a dynamic IP address Establishing access to the device via internetExample for an executable Html Embedding live video images in a dedicated HtmlEmbedding live video images Embedding still picturesService mode Configuring user names IndexDokument Nr. A24205-A336-B383

CFVA-IP specifications

Siemens CFVA-IP is an advanced control system designed for industrial automation, combining performance, flexibility, and reliability to meet the diverse demands of modern manufacturing processes. This system is engineered to operate seamlessly across various industries, including automotive, food and beverage, and pharmaceuticals.

One of the primary features of the CFVA-IP is its integration capability with existing infrastructure. It supports a wide array of communication protocols, allowing for easy connection with legacy systems and new components alike. This ensures a smooth transition and interoperability within the industrial ecosystem, reducing downtime and enhancing productivity.

The CFVA-IP utilizes state-of-the-art technologies, such as Ethernet and IP-based communication, to facilitate high-speed data transfer and real-time control. This enables operators to monitor processes and make informed decisions quickly. The system is equipped with advanced diagnostic tools that provide insights into operational performance, helping to identify potential issues before they escalate into significant problems.

A notable characteristic of the Siemens CFVA-IP is its modular design. This allows for easy customization and scalability, enabling manufacturers to expand their systems as needed without significant overhauls. Users can select from various input/output modules, communication interfaces, and power supplies to tailor the system to their specific applications and requirements.

Additionally, the CFVA-IP features comprehensive safety measures, including built-in redundancy and support for safety protocols. It complies with international safety standards, ensuring that operations can continue securely even in critical scenarios. This feature is particularly essential in industries where safety and regulatory compliance are paramount.

Another significant advantage of the Siemens CFVA-IP is its user-friendly interface. The system includes intuitive software tools designed to ease programming and control. The graphical interface simplifies configuration and monitoring, allowing even less technically inclined users to operate the system efficiently. Moreover, training tools and extensive documentation are available, ensuring that staff can quickly adapt to the new system.

In conclusion, Siemens CFVA-IP stands out as a versatile and robust solution for industrial automation. Its combination of integration capability, advanced technologies, modular design, safety features, and user-friendly interface makes it an ideal choice for companies looking to modernize their manufacturing processes while maintaining efficiency and reliability. The CFVA-IP not only meets current automation needs but is also poised to adapt to future challenges in the ever-evolving industrial landscape.