Siemens CFVA-IP user manual Contents

Page 3

Contents

1

Introduction

5

2

General Safety Precautions

6

3

Ordering data

7

3.1

Ordering data for IP-ModuleCFVA-IP

7

3.2

Ordering data for IP-ModuleCVVA-IP

7

4

Norms and Directives

8

5

Technical data

9

5.1

Technical data for IP-ModuleCFVA-IP

9

5.2

Technical data for IP-ModuleCVVA-IP

10

6

Installing the IP-Module

11

6.1

Installing IP-Module type CFVA-IP

11

6.2

Installing IP-Module type CVVA-IP

12

7

Establishing initial communication with the device

14

7.1

Changing the IP address of the client PC

14

7.2

Mapping a network route

14

8

Checking device accessibility

16

9

Device homepage

17

9.1

Calling up the device homepage

17

9.1.1

Calling up the device homepage using Microsoft Internet Explorer

17

9.1.2

Calling up the device homepage using the Web-Cam IP Manager

17

9.2

Components of the device homepage

19

10

Configuring network settings

20

10.1

Changing the device IP address

21

9.1.1.

Changing the device IP address via the device homepage

21

9.1.2

Changing the IP address using the Web-Cam IP Manager

22

11

Configuring image parameters

24

11.1

Configuring general image parameters

24

11.2

Configuring text overlay

24

11.3

Configuring JPEG encoder settings

25

12

Setting the date and time

27

13

Configuring user names and passwords

28

14

Restarting the IP Module

29

15

Live video

31

15.1

Displaying live video

31

15.2

Setting live video resolution

32

15.3

Storing still pictures

32

16

Establishing access to the device via internet

33

17

Embedding live video images in a dedicated HTML page

35

18

Service mode

36

19

Index

37

 

 

3

Siemens Building Technologies

Fire Safety & Security Products

Image 3
Contents IP-Module IP-Module CFVA-IP IP-Module CVVA-IP Page Contents Page About this manual IntroductionGeneral Safety Precautions Ordering data Ordering data for IP-Module CFVA-IPOrdering data for IP-Module CVVA-IP EU Directive Norms and DirectivesTechnical data for IP-Module CFVA-IP Technical dataTechnical data for IP-Module CVVA-IP IP-Module fixing Installing the IP-ModuleInstalling IP-Module type CFVA-IP Installation and connection of the dome cameraExploded view of IP-Module CVVA-IP Installing IP-Module type CVVA-IPIP-Module fixing Control panel Network connections Establishing initial communication with the deviceChanging the IP address of the client PC Mapping a network routeEstablishing initial communication with the device Ping xxx.xxx.xxx.xxx xxx.xxx.xxx.xxx = Checking device accessibilityUsing Internet Explorer Using the Web-Cam IP Manager Device homepageCalling up the device homepage Click on the Home page of selected device... button Device homepage Components of the device homepageConfiguring network settings Automatic address designation by the Dhcp or Bootp server Changing the device IP addressManual IP address and subnet mask allocation Example Changing the IP address using the Web-Cam IP ManagerConfiguring network settings Configuring image parameters Configuring general image parametersConfiguring text overlay Overlay text color Configuring Jpeg encoder settingsOverlay text Overlay text positionPAL/CCIR NTSC/EIA Setting the date and time Factory set user names Configuring user names and passwordsManual restart Restarting the IP ModuleRestart by Ping Watchdog Activate the Enable restart by Ping-Watchdog check boxLive video Displaying live videoDisplaying live video Standard Setting live video resolutionStoring still pictures LowDynamic IP address Establishing access to the device via internetConnecting to internet Static IP addressEstablishing access to the device via internet Example of access using a dynamic IP addressEmbedding still pictures Embedding live video images in a dedicated HtmlEmbedding live video images Example for an executable HtmlService mode Index Configuring user namesDokument Nr. A24205-A336-B383

CFVA-IP specifications

Siemens CFVA-IP is an advanced control system designed for industrial automation, combining performance, flexibility, and reliability to meet the diverse demands of modern manufacturing processes. This system is engineered to operate seamlessly across various industries, including automotive, food and beverage, and pharmaceuticals.

One of the primary features of the CFVA-IP is its integration capability with existing infrastructure. It supports a wide array of communication protocols, allowing for easy connection with legacy systems and new components alike. This ensures a smooth transition and interoperability within the industrial ecosystem, reducing downtime and enhancing productivity.

The CFVA-IP utilizes state-of-the-art technologies, such as Ethernet and IP-based communication, to facilitate high-speed data transfer and real-time control. This enables operators to monitor processes and make informed decisions quickly. The system is equipped with advanced diagnostic tools that provide insights into operational performance, helping to identify potential issues before they escalate into significant problems.

A notable characteristic of the Siemens CFVA-IP is its modular design. This allows for easy customization and scalability, enabling manufacturers to expand their systems as needed without significant overhauls. Users can select from various input/output modules, communication interfaces, and power supplies to tailor the system to their specific applications and requirements.

Additionally, the CFVA-IP features comprehensive safety measures, including built-in redundancy and support for safety protocols. It complies with international safety standards, ensuring that operations can continue securely even in critical scenarios. This feature is particularly essential in industries where safety and regulatory compliance are paramount.

Another significant advantage of the Siemens CFVA-IP is its user-friendly interface. The system includes intuitive software tools designed to ease programming and control. The graphical interface simplifies configuration and monitoring, allowing even less technically inclined users to operate the system efficiently. Moreover, training tools and extensive documentation are available, ensuring that staff can quickly adapt to the new system.

In conclusion, Siemens CFVA-IP stands out as a versatile and robust solution for industrial automation. Its combination of integration capability, advanced technologies, modular design, safety features, and user-friendly interface makes it an ideal choice for companies looking to modernize their manufacturing processes while maintaining efficiency and reliability. The CFVA-IP not only meets current automation needs but is also poised to adapt to future challenges in the ever-evolving industrial landscape.