Sharp AE-X12MCJ, AY-X18MCJ, AY-X09MCJ, AY-X12MCJ, AE-X09MC0J operation manual 220-240V

Page 28

Specifications

Model

 

 

 

AY-X09MCJAE-X09MCJ

 

 

 

 

 

 

 

Function

 

 

 

COOLING

 

HEATING

 

 

 

 

 

 

Rated Voltage

 

 

220240V

Frequency(Hz) (High/Standard *)

 

 

50HZ

 

 

 

 

 

 

Total Capacity (W) (High/Standard *):

 

3300/2600/ 1188(W)

 

3800/2850/1109 (W)

Total Capacity (Btu/h) (High/ Standard *):

11200/9000/4063(Btu/h)

 

13000/9800/3792(Btu/h)

 

 

 

 

 

 

Power Input (W) (High/ Standard*)

 

1200/610/264

 

1250/670/230

 

 

 

 

 

 

Rated Input (W) (High/ Standard *)

 

1200

 

1280

 

 

 

 

 

 

Rated Current (A) (High/ Standard *)

 

5.5

 

6.0

 

 

 

 

 

 

Air Flow Volume (m3/h) (H/M/L)**

 

 

450

Dehumidifying Volume (l/h)

 

 

 

0.8

 

 

 

 

 

 

EER / C.O.P (W/W)

 

 

4.25

 

4.22

 

 

 

 

 

 

 

Energy Class

 

 

 

 

A/A

 

 

 

 

 

 

Model of Indoor Unit

 

AY-X09MCJ

 

Fan Motor Speed (r/min) (SH/M/L)

1350/1100 /950l/820

 

 

 

 

 

 

Output of Fan Motor (w)

 

 

10

 

 

 

 

 

 

Fan Type-Piece

 

 

Cross flow fan – 1

 

 

 

 

 

Diameter-Length (mm)

 

φ85 X 668

 

 

 

 

 

 

Evaporator

 

 

Aluminum fin-copper tube

 

 

 

 

 

 

Row-Fin Gap(mm)

 

 

2-1.5

 

 

 

 

Coil length (l) x height (H) x coil width (L)

657X285X25.4

 

 

 

 

Indoor

Swing Motor Model

 

MP28VB

 

 

 

 

 

 

Output of Swing Motor (W)

 

 

2

unit

 

 

 

 

 

 

 

 

Fuse (A)

 

 

PCB 3.15A

 

Transformer 0.2A

 

 

 

 

 

 

 

 

 

 

 

 

Sound Pressure

Level

dB (A)

42/ 38 / 30/28

 

(S/H/M/L)

 

 

 

 

 

 

 

 

 

 

 

 

Sound Power Level dB (A) (S/H/M/L)

53/ 47/ 40/38

 

 

 

 

 

Dimension (W/D/H)( mm)

 

872X178X283

 

 

 

 

 

 

 

 

Dimension

of

Package

935x260X375

 

(W/D/H)( mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

Net Weight /Gross Weight (kg)

 

12/15

 

 

 

 

 

 

 

- 24 -

Image 28
Contents Split Type Inverter Room Air Conditioner Page Specifications Page Page Objects Page Name and function of each part Auto Name and function of wireless remote control Sel ect Turbo 。 。 Page Care and Cleaning Removing Page Water condensation occurs naturally Page 8m above the floor Page Installation dimension diagram Installing the indoor unit Installing the indoor unit Installing the Outdoor Unit Installing the Outdoor Unit Page 220-240V Outdoor AY-X12MCJ;AE-X12MCJ AE-X12MCJ AY-X18MCJ;AE-X18MCJ Outdoor unit $LU&RQGLWLRQHUV 1300 135 66129905916