Sharp AY-X09MCJ, AY-X18MCJ, AY-X12MCJ, AE-X09MC0J operation manual AE-X12MCJ

Page 31

 

Model of Outdoor Unit

 

AE-X12MCJ

 

 

 

 

 

Compressor Manufacturer/trademark

SANYO

 

 

 

 

 

Compressor Model

 

C-6RZ110H1A

 

 

 

 

 

Compressor Type

 

Double Rotary

 

 

 

 

 

 

L.R.A. (A)

 

 

33

 

 

 

 

 

Compressor RLA(A)

 

4.59

 

 

 

 

 

Compressor Power Input(W)

 

800

 

 

 

 

 

Overload Protector

 

Int11l-3979

 

 

 

 

 

Throttling Method

 

Capillary throttling

 

 

 

 

 

 

Starting Method

 

 

Transducer starting

 

 

 

 

 

Working Temp Range ()

 

-7℃≤T43

 

 

 

 

 

 

Condenser

 

 

Aluminum fin-copper tube

 

 

 

 

 

Rows-Fin Gap(mm)

 

2-1.4

 

 

 

 

 

Coil length (l) x height (H) x coil width (L)

608X508X44

 

 

 

 

 

Fan Motor Speed (rpm)

 

830±20

 

 

 

 

 

Output of Fan Motor (W)

 

30

 

 

 

 

 

Air Flow Volume of Outdoor Unit (m3/h)

1900

Outdoor

Fan Type-Piece

 

 

Axial fan –1

unit

Fan Diameter (mm)

 

400

 

Defrosting Method

 

Auto defrost

 

 

 

 

 

 

Climate Type

 

 

T1

 

 

 

 

 

 

Isolation

 

 

I

 

 

 

 

 

Moisture Protection

 

IP24

 

 

 

 

 

 

Permissible

Excessive

Operating

3.8

 

Pressure for the Discharge Side(MPa)

 

 

 

 

 

 

 

 

Permissible

Excessive

Operating

1.2

 

Pressure for the Suction Side(MPa)

 

 

 

 

 

 

 

Sound Pressure Level dB (A) (H/M/L)

54

 

 

 

 

 

Sound Power Level dB (A) (H/M/L)

64

 

 

 

 

 

Dimension (W/D/H)( mm)

 

848X320X540

 

 

 

 

 

Dimension of Package (W/D/H)( mm)

878X360X590

 

 

 

 

 

Net Weight /Gross Weight (kg)

 

40/45

 

 

 

 

 

Refrigerant Charge (kg)

 

1.27

 

 

 

 

Connection

Liquid line diameter(mm)

 

φ6(1/4")

Pipe

Gas line diameter(mm)

 

φ9.52(3/8")

 

 

 

 

 

- 27 -

Image 31
Contents Split Type Inverter Room Air Conditioner Page Specifications Page Page Objects Page Name and function of each part Auto Name and function of wireless remote control Sel ect Turbo 。 。 Page Care and Cleaning Removing Page Water condensation occurs naturally Page 8m above the floor Page Installation dimension diagram Installing the indoor unit Installing the indoor unit Installing the Outdoor Unit Installing the Outdoor Unit Page 220-240V Outdoor AY-X12MCJ;AE-X12MCJ AE-X12MCJ AY-X18MCJ;AE-X18MCJ Outdoor unit $LU&RQGLWLRQHUV 1300 135 66129905916