Sharp AF-R140DX, AF-100DX On Timer Operation, When the unit is not operating, 1delay d start time

Page 14
• SELECTOR indicator and TIMER indicator will light.
• The time display will count down the remain- ing time.
• The unit will start when the set time expires. The temperature setting will be displayed.
TO CANCEL THE TIMER SETTING
Touch the TIMER ON/OFF pad again after the timer is set, or press the TIMER ON/OFF pad until CL(cancel) appears on the display.

HOW TO OPERATE

ON TIMER OPERATION

• This unit has a built-in timer that can be programmed to start the unit up to 12 hours in advance. You can set the timer to start in increments of 30 minutes (0.5 hours) up to 9.5 hours in advance

of the start time,

in 1 hour increments from 10 to 12 hours in advance of the start time.

• The unit will start

utomatically according to your setting.

SELECTORindicator

When the unit is not operating

 

 

 

 

 

Touch the TIMER ON/OFF pad to set t e

 

F

 

1delay d start time.

 

 

 

 

 

 

 

 

 

 

• The ime setting will change as you touch t e

 

hr

pad. The display will change as follows;

COOLSELECT/ORFANTEMP TIMERON/OFF ENERGSAVERY PON/OFFOWER

et(0.5h)

0.5h

1.0h

.5h

 

 

0h

 

 

12h

1

1h

 

 

Previoussetting

CL(cancel)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TIMERTIMERON/OFFindicatorpad

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• The timer will be set, 5 seconds after the

 

 

TIMER ON/OFF pad is touched for the last

time.

(If you wish to start the operation 6 hours and 30 minutes later, set the delay time as shown above.)

NOTES FOR TIMER SETTING AND OPERATION:

After setting the TIMER, change the temperature and fan speed settings as shown on pages 11 and 12. When the temperature is set in the timer mode, the temperature will show in the display for 5 seconds and then return to the time display.

The last setting used will be memorized and will appear on the display the next time you operate the unit with the TIMER function.

If a power failure occurs while the ON or OFF TIMER is set, the TIMER memory will be cancelled and will not resume even after power is reinstated. The unit will not automatically start.

OFF TIMER OPERATION can also be set with the REMOTE CONTROL.

14

Image 14
Contents AF-R100DX AF-R120DX AF-R140DX Accessories Additional Customer Information For Your ProtectionConsumer Limited Warranty Consumer Limited WarrantyLocation Installation InstructionsCheck Window Area Suggested Tools InstallationItems Packed with this Unit Front panel. Keep them as they will Secure the cabinet to the window Precautions Grounding InstructionsPrecautions Energy Efficiency TipsHOW to Operate 987ON/OFF pad again To Change Temperature SettingTouch Power ON/OFF pad During operation Change FAN Speed and Operation ModeOperation mode and fan speed Touch Selector pad and selectExhaust Energy SaverTo Change AIR Flow Direction During cooling operation Touch Energy Saver pad1delay d start time On Timer OperationWhen the unit is not operating To Cancel the Timer Setting OFF Timer OperationWhen the unit is operating Using the Remote Control Use two size-AAA R03 batteriesTransmitter Cleaning and Maintenance Remove the FilterAIR Conditioner does not Operate AT ALL Timer does not Work ProperlyIf the Unit Fails to Receive the Remote Control Signal AIR Conditioner does not Properly CoolSharp Electronics Corporation

AF-R140DX, AF-100DX, AF-R120DX, AF-S120DX, AF-S100DX specifications

The Sharp AF series air conditioners, including models AF-R140DX, AF-100DX, AF-S120DX, AF-S100DX, and AF-R120DX, are renowned for their advanced cooling technologies, energy efficiency, and user-friendly features. These units are designed to provide comfort in varying climate conditions while ensuring optimal energy consumption.

One of the standout features of the AF series is its Intelligent Cooling technology. This innovation allows for faster cooling times, enabling the units to reach the desired temperatures quickly, enhancing comfort during hot summer months. Additionally, these models incorporate a multi-stage filtration system, which includes a pre-filter and HEPA filter, ensuring that the air circulated is clean and free from dust, allergens, and pollutants.

Energy efficiency is a critical characteristic of the AF series. With a high Energy Efficiency Ratio (EER), these air conditioners minimize electricity consumption while providing effective cooling. This not only helps reduce utility bills but also contributes to a smaller carbon footprint, aligning with environmental sustainability goals.

The AF-R140DX and AF-R120DX models come equipped with inverter technology, allowing for variable speed compressor operation. This feature adjusts the cooling output according to the room's temperature, thereby maintaining a consistent environment without unnecessary energy expenditure. The AF-100DX, AF-S120DX, and AF-S100DX models also offer impressive performance but differ in cooling capacity and design suited for specific room sizes.

Moreover, user convenience is a priority with the AF series. Most models include a simple-to-use remote control functionality, allowing users to adjust settings from a distance. The programmable timer and sleep mode ensure that homeowners can set cooling schedules according to their preferences, enhancing comfort while optimizing energy usage.

Design-wise, Sharp’s AF air conditioners boast a sleek and modern appearance that can fit seamlessly into any room decor. Their compact size makes them suitable for both residential and commercial spaces.

In summary, the Sharp AF-R140DX, AF-100DX, AF-S120DX, AF-S100DX, and AF-R120DX air conditioners stand out with their intelligent cooling capabilities, energy-efficient operation, advanced filtration systems, and user-friendly designs, making them ideal solutions for those seeking comfort and efficiency in air conditioning.