Sharp R-2397 Service Information, Microwave Measurement, Requirement, Preparation for Testing

Page 31

R-2397

SERVICE INFORMATION

IMPORTANT: When replace the magnetron MG1 and/or MG2, the relays RY3 and RY4 on control unit must be replaced at the same time. Because if the magnetron's life has been over, the relay's life may also be over.

MICROWAVE MEASUREMENT

After adjustment of door latch switches, monitor switch and door are completed individually or collectively, the following leakage test must be performed with a survey instrument and it must be confirmed that the result meets the requirements of the performance standard for micro- wave oven.

REQUIREMENT

The safety switch must prevent microwave radiation emission in excess of 5mW/cm2 at any point 5cm or more from external surface of the oven.

PREPARATION FOR TESTING:

Before beginning the actual test for leakage, proceed as follows;

1.Make sure that the test instrument is operating nor- mally as specified in its instruction booklet. Important:

Survey instruments that comply with the requirement for instrumentations as prescribed by the perform- ance standard for microwave ovens must be used for testing.

Recommended instruments are:

NARDA 8100

NARDA 8200

HOLADAY HI 1500

SIMPSON 380M

2.Place the oven tray into the oven cavity.

3.Place the load of 275 ± 15ml of water initially at 20

± 5˚C in the centre of the oven tray. The water container should be a low form of 600 ml beaker with inside diameter of approx. 8.5cm and made of an electrically non-conductive material such as glass or plastic.

The placing of this standard load in the oven is impor- tant not only to protect the oven, but also to insure that any leakage is measured accurately.

4.Close the door and turn the oven ON with the timer set for several minutes. If the water begins to boil before the survey is completed, replace it with 275ml of cool water.

5.Move the probe slowly (not faster that 2.5cm/sec.) along the gap.

6.The microwave radiation emission should be meas- ured at any point of 5cm or more from the external surface of the oven.

mW cm 2

mW cm 2

Microwave leakage measurement at 5 cm distance

29

Image 31
Contents Commercial Microwave Oven Table of Contents2397 General Important Information Sharp Corporation OSAKA, JapanCommercial 2397Description SpecificationProduct Description General InformationOperating Keys Installation InformationDisplay and Indicators Appearance ViewMicrowave Variable Cooking Operation SequenceOFF Condition Microwave Cooking ConditionFunction of Important Components Magnetron Thermistor Asymmetric RectifierExhaust Thermistor Intake ThermistorRemember to Check 4R Troubleshooting GuideServicing Remember to Check 3DPlugged into wall outlet Test Procedure Possible Cause Defective PartsTemperature of Intake Thermistor is High Around 20 C Power supply Voltage Rated voltage Test ProceduresProcedure Component Test Letter Magnetron Test Microwave Output Power IEC-705-1988Carry OUT 4R Checks Procedure Letter Component TestHigh Voltage Transformer Test Carry OUT 3D ChecksWeak Point A018 Procedure Component Test LetterSwitch Test High Voltage Capacitor Test Carry OUT 3D ChecksMonitor Resistor Test Carry OUT 3D Checks Fuse F6.3A TestThermal CUT-OUT Test Carry OUT 3D Checks Table Thermal Cut-out TestMotor Winding Test Procedure Component Test Letter Magnetron Thermistor TestExhaust Thermistor Test Intake Thermistor TestMin Cx ± 20% Cy ± 20% 5mH Touch Control Panel Assembly TestKEY Unit Test Circuity Test Procedures ContdTo determine if the control unit or key pad is at fault Relay TestExhaust Air Temperature Detecting Circuit Power Supply CircuitPower Sync Signal Generating Circuit Stop Switch CircuitDescription of LSI LSIIZA646DR Signal coming from touch key Pin No Signal DescriptionInternal clock oscillation frequency setting input Power source voltageSound Voltage level control terminal Servicing of Touch Control Panel Other PrecautionsServicing Shapes of Electronic ComponentsPractice for checking total service counts eg 234,567 Counts Procedure for Entering to IC-2Other Checking and Clearing PRO Cedure To check the contents of defrost Flicker / 0.1 sec BuzzerTo remove the components, proceed as follows Component Replacement and Adjustment ProcedureOuter Case Removal High Voltage Components RemovalStirrer Motor Upper Removal Magnetron RemovalHigh Voltage Transformer Removal Blower Motor RemovalProcedure Control Panel Assembly and Control Unit RemovalHOW to Release the Positive Lock Connector Control Panel Assembly RemovalRe-install Power Supply Cord ReplacementAfter adjustment, make sure of the following Choke Cover Removal Door Replacement and AdjustmentDoor Replacement Door AdjustmentRequirement Service InformationPreparation for Testing Microwave MeasurementFigure O-1. Oven SChematic-OFF Condition High Voltage Components C d e CircuitFigure S-3. Printed Wiring Board Cabinet Parts Parts ListParts marked * are used in voltage more than Electric PartsVCEAB31HW104M Door Parts Oven PartsSCRE, Nuts and Washers MiscellaneousDescription HOW to Order Replacement PartsModel Number REF. noOven and Cabinet Parts Control Panel Parts Door Parts Not replaceable items 2397

R-2397 specifications

The Sharp R-2397 is a high-performance microwave oven that combines advanced technology with user-friendly features, making it a popular choice for modern kitchens. This model stands out due to its sleek design and efficient functionality, catering to both cooking enthusiasts and busy households alike.

One of the most notable features of the Sharp R-2397 is its powerful microwave cooking capabilities. With a wattage rating of 900 watts, it ensures that food is cooked evenly and quickly, allowing users to prepare meals in a fraction of the time compared to conventional ovens. The unit also offers multiple power levels, enabling precise cooking adjustments for various types of food, from defrosting to reheating and everything in between.

Another key characteristic of the R-2397 is its spacious interior. With a generous capacity of 23 liters, this microwave can accommodate larger dishes, making it suitable for families or individuals who enjoy hosting gatherings. The turntable feature promotes even cooking by rotating food continuously, ensuring that every inch is heated uniformly.

Additionally, the Sharp R-2397 is equipped with a range of convenient presets and auto-cook functions. These pre-programmed settings allow users to optimize cooking times for common dishes, such as popcorn, vegetables, and frozen meals, simplifying meal preparation and enhancing user experience. The intuitive control panel is designed to be user-friendly, ensuring that anyone can operate the microwave with ease.

Safety is also a significant consideration in the design of the Sharp R-2397. The unit comes with a child lock function, preventing accidental operation and ensuring that the oven is used safely in households with young children. This feature adds peace of mind for parents while using the appliance in their daily routines.

Moreover, the R-2397 incorporates a modern aesthetic that can fit into various kitchen styles. Its polished exterior and compact design make it both attractive and practical, with the added advantage of easy cleaning and maintenance.

In summary, the Sharp R-2397 is a versatile microwave oven that offers a blend of power, efficiency, and user-centric features. With its high wattage, spacious interior, smart presets, and safety measures, it is an excellent addition to any kitchen, catering to everyday cooking needs and helping to simplify meal times. Whether reheating leftovers or cooking a new recipe, the Sharp R-2397 sets itself apart as a reliable kitchen companion.