Bosch Appliances D9412GV4 installation instructions Specifications

Page 27

Control PanelSpecifications en 27

5

Specifications

 

 

 

 

 

 

 

 

 

 

 

Voltage Input

Primary:

 

Terminals 1 and 2

16.5 VAC 40 VA class 2 plug-in

 

(Power Supply)1

 

 

 

 

transformer (D1640)

 

 

 

 

 

 

 

 

 

Secondary:

 

Terminals 4 and 5

Sealed lead-acid rechargeable battery

 

 

 

 

 

 

(12.0 VDC, 7 Ah or 12.0 VDC, 17.2 or 18

 

 

 

 

 

 

Ah). The control panel supports up to two

 

 

 

 

 

 

12.0 VDC, 7 Ah batteries using the D122/

 

 

 

 

 

 

D122L Dual Battery Harness or two

 

 

 

 

 

 

D1218 (12.0 VDC, 17.2 or 18 Ah)

 

 

 

 

 

 

batteries using a D122/D122L.

 

 

 

 

 

 

 

Current

Control Panel: Idle 225 mA; Alarm 300 mA. Refer to the Current Rating

 

Requirement

Chart for Standby Battery Calculations section in the D9412GV4/D7412GV4

 

 

v2.00 Installation and System Reference Guide (P/N: F01U265457) for the

 

 

current draw requirements of other system components.

 

 

 

 

 

Power Outputs2

All external connections are power-limited except battery terminals

 

 

 

 

 

 

 

 

Continuous

 

Terminals 3,

1.4 A maximum at 12.0 VDC Nominal

 

 

Power

 

24, 32, 36

(continuous supply) total for all devices

 

 

Outputs

 

 

and outputs supplied at Terminals 3, 24,

 

 

 

 

 

 

32, and 36.

 

 

 

 

 

 

 

 

Alarm Power

 

Terminals 6

2.0 A maximum at 12.0 VDC Nominal

 

 

Output

 

and 7

output. Output can be steady or one of

 

 

 

 

 

 

four pulsed patterns depending on

 

 

 

 

 

 

programming. Refer to Outputs in RPS

 

 

 

 

 

 

Help.

 

 

 

 

 

 

 

 

Switched

 

Terminal 8

1.4 A maximum at 12.0 VDC Nominal

 

 

Aux Power

 

 

output. Continuous output is interrupted

 

 

 

 

 

 

by Sensor Reset, or alarm verification

 

 

 

 

 

 

depending on programming. Refer to

 

 

 

 

 

 

Outputs in RPS Help.

 

 

 

 

 

 

 

Fire and Fire/

To comply with UL 985 and 864 listing standards for fire

 

 

Burglary

 

alarm systems, the total combined continuous and alarm

 

 

Systems

 

current draw for the system during alarm conditions must

 

 

 

 

 

be limited to 1.4 A provided by the primary power supply

 

 

 

 

 

(rectified AC). If current draw for the system exceeds 1.4

 

 

 

 

 

A, use a UL Listed 12 VDC regulated, power limited

 

 

 

 

 

auxiliary power supply module such as the B520 (refer to

 

 

 

 

 

the Keyswitch Wiring section).

 

 

 

 

 

 

1Requires a UL Listed power supply.

 

 

2For UL 864 applications, refer to 6.0 Compatibilities for compatible devices.

 

 

 

 

 

 

 

Minimum

10.2 VDC

 

 

 

 

Operating

 

 

 

 

 

 

Voltage

 

 

 

 

 

 

 

 

 

 

 

SDI Bus

SDI Bus A+:

 

9 VDC 15000 ft (4572 m) maximum

 

 

 

 

 

 

 

Bosch Security Systens, Inc.

UL Installation Instructions

2012.12 02 F.01U.265.462

Image 27
Contents Control Panel Page Table of contents Introduction About documentationDates Mounting Enclosure InstallationInstallation Preparation Enclosure OptionsCallout Description Installing the Control PanelTerminal Connecting Earth GroundGround Fault Detect Enable Enabling Ground Fault DetectionGround Fault Impedance Specifications 5Locking the Reset PinImpedance Control Panel Detects Ground Fault Reset Pin Reset pin locked closed Reset pin normal open1Faceplates 3DiagramsPhone Power Supply Side Wiring DiagramsSystem Wiring Diagram VDC regulated, power-limited power supplyD9412GV4/D7412GV4 Input Points and Peripheral Devices For D129, use zero retard except for waterflow devices SDI Devices Wiring Diagrams D9412GV4 SDI and Zonex Devices System Wiring DiagramCallout ᅳ Description D7412GV4 SDI and Zonex Devices System Wiring Diagram D7412GV4 SDI and Zonex Devices System Wiring DiagramD9412GV4/D7412GV4 Capacities Module D9412GV4/D7412GV4 SDI2 Devices System WiringTerminals 24 through 36 are power limited, supervised Structions P/N F01U030068Module D9412GV4 D7412GV4 1SDI2 Bus Wiring Recommendations Following rules must be followed when wiring the SDI2 busMaximum cable lengths Use Non-shielded cable only Keyswitch WiringCapacitance ratings of the wire being used Cable Overall Capacitance LengthInstalling the Transformer Power Supply and Power OutputsPower Supply Primary Primary AC Power CircuitPower Terminals Secondary Secondary DC PowerInstalling the Battery Battery Terminals Battery terminals. Terminal 5 is non-power limitingNon-PowerLimited Wiring Power Outputs Circuit Protection32, Power Outputs Total Available PowerPower Outputs Continuous Power Output Terminals 3, 8 Power Outputs Programmable Power Output Terminals 6Voltage Output at Terminals 6, 7, Fire System Power FormulaAvailable Power Terminals 64Terminal Verification/Reset OutputSpecifications Connections BatterySDI2 Bus TelephoneB520 Specifications Terminal Requirements Description Terminal Wiring RequirementsPoint 7/8 Common Zonex PowerBUS a SDI Power Point 5/6SDI2 Power CompatibilitiesModel Title Intrusion CUL 985 3RFDW-SM-A IST-EZTS3RFBT-A 3RFDW-RM-ANotification Appliance Circuit NAC 4Circuit ClassesOnboard Points Zonex Bus or BusesPage Bosch Security Systems, Inc
Related manuals
Manual 32 pages 42.2 Kb

D9412GV4 specifications

Bosch Appliances has long been synonymous with quality and innovation in the home appliance market. The D7212GV4, D7412GV4, and D9412GV4 models are part of their esteemed line of high-performance appliances, designed to meet the demands of modern kitchens and households. These models come equipped with advanced features and technologies to enhance user experience, efficiency, and convenience.

The D7212GV4 is characterized by its compact design, making it ideal for smaller kitchens or spaces where every inch counts. Despite its size, it boasts impressive functionality, including multiple cooking modes that allow users to prepare a variety of dishes with ease. Its intuitive interface ensures that even novice cooks can operate it effortlessly.

In contrast, the D7412GV4 offers a balance of capacity and features. It includes a larger cooking area, which is perfect for families or for those who frequently entertain guests. This model is highlighted by its state-of-the-art steam cooking technology, which helps retain nutrients in food while ensuring moist and tender results. Additionally, the D7412GV4 has a built-in self-cleaning feature, making maintenance and upkeep considerably easier for busy homeowners.

Meanwhile, the D9412GV4 showcases Bosch’s commitment to premium quality and performance. This high-end model is designed for the serious home chef, combining powerful heating elements with advanced temperature control for professional-grade results. One of the standout features of the D9412GV4 is its induction cooking technology, which offers rapid heating and precise temperature adjustments, making cooking faster and more efficient. This model is also equipped with smart connectivity, allowing users to control and monitor their cooking process remotely via a dedicated app.

All three models in this series emphasize energy efficiency, with Bosch appliances consistently meeting or exceeding Energy Star standards. They include sleek designs that integrate seamlessly into any kitchen décor, whether contemporary or traditional. Additional features such as safety locks, child-proof settings, and easy-to-clean surfaces enhance their appeal, making them a practical choice for families.

In summary, the Bosch D7212GV4, D7412GV4, and D9412GV4 appliances capture the essence of modern cooking with their blend of compact design, advanced technologies, and user-friendly features. These models represent Bosch's dedication to innovation, performance, and sustainability, making them a wise investment for any home.