Tefal TW185988 manual Troubleshooting

Page 13

Open the lid (8) of your vacuum cleaner fig. 13.

Pull out the HEPA* filter cassette (13) - fig. 31-32.

Tap the HEPA* filter cassette (13) on the top of a bin - fig. 33.

Then pass it through clear water, fig 34 and let it dry for at least 24 hours- fig 35.

Ensure that the HEPA* filter cassette (13) is fully dry before re-inserting it in the machine.

Place the pins in the notches- fig. 36.

Adjust the HEPA* filter cassette (13) in its compartment - fig. 37.

Make sure the HEPA* filter cassette (13) is properly positioned before closing the lid. (8).

CHANGING THE HEPA FILTER CASSETTE * (Ref. XC0005 01)

Open the lid (8) of your vacuum cleaner fig. 13..

Pull out the HEPA* filter cassette (13) - fig. 38-39.

Put the cassette in the bin- fig.40.

Place the pins of the new HEPA* filter cassette in the notches - fig 41.

Adjust the new HEPA* filter cassette (13) in its compartment - fig. 42.

Make sure the HEPA* filter cassette (13) is properly positioned before closing the lid. (8).

CLEANING THE VACUUM CLEANER

Wipe the body of the appliance and the accessories with a soft damp cloth, then dry.

Wipe the lid with a dry cloth -fig. 43.

Do not use aggressive or abrasive detergents.

EN

6. TROUBLESHOOTING

Important : As soon as your vacuum cleaner begins to work less well than usual, switch it off by pressing on the On/off pedal, before doing any checking.

YOUR VACUUM CLEANER DOES NOT START

• The appliance is not connected to a power supply . Check that the appliance is correctly connected.

IF YOUR VACUUM CLEANER HAS NO SUCTION

An accessory or the flexible tube is blocked : unblock the accessory or the flexible tube.

The lid is not properly closed : Check the positioning of the bag and close the lid again.

IF YOUR VACUUM CLEANER LOSES SUCTION, MAKES NOISE, WHISTLES

An accessory or the flexible tube is partially blocked. Unblock the accessory or the flexible tube.

The bag is full, or saturated with fine dust : replace the paper bag (16a), or empty the textile bag* (16b).

The “bag full” indicator is red : the filtration system is saturated.

-HEPA* Cassette : change the HEPA* cassette (13) and replace it in position, or wash the HEPA* cassette (13) according to the procedure.

-Micro filter* : take out the micro filter* and replace it with a new one.

• The mechanical power control is open : close the mechanical power control.

IF THE “BAG FULL” INDICATOR STAYS RED

• The bag is full. Replace the paper bag, (16a) or empty the textile bag* (16b).

IF THE LID DOES NOT CLOSE (filter presence detector 13bis activated)

Check that you have installed a HEPA* filter cassette (13) or motor protection grill (11) and check that it is correctly positioned.

IF THE SUCTION NOZZLE IS DIFFICULT TO MOVE

• Open the regulator to turn down the power.

IF THE CABLE DOES NOT COMPLETELY RETRACT

The cable is held back by something outside its entry point : straighten out the cable and press on the cable return pedal.

* According to model: this is either equipment specific to certain models or available as an optional accessory

Image 13
Contents Mini Space 16 a 16 B 24h 24h Description Conseils DE SécuritéConditions D’UTILISATION Alimentation ÉlectriqueUtilisation Avant LA Première UtilisationDéballage Conseils ET PrécautionsBranchement DU Cordon ET Mise EN Marche DE L’APPAREIL Nettoyage ET MaintenanceRangement ET Transport DE L’APPAREIL Changez DE SACDépannage Environnement LES AccessoiresGarantie Electrical Power Supply Safety RecommendationsConditions of USE RepairsUsing the Appliance Before Using for the First TimeTips and Precautions Assembly of the Parts of the ApplianceConnecting the Cable and Starting Your Appliance Cleaning and MaintenanceStoring and Transporting the Appliance Changing the BAGTroubleshooting Warranty AccessoriesEnvironment Page Page Page Page Page Page