Soleus Air SG-DEH-70EP-2 manual Error Codes, Product Specifications, KEY Features

Page 5

ERROR CODES

Error Code

Error Type

Possible Cause

 

Corrective Action

 

 

 

 

 

 

F1

Ambient

Tem-

1. Sudden Change in

1.

Unplug the dehumidifier.

 

perature Sensor

the surrounding

2.

Check the surrounding area for

 

Malfunction

temperature.

 

possible reasons for sudden

 

 

 

 

 

temperature changes.

 

 

 

 

3.

Wait 30 minutes before plug-

 

 

 

 

 

ging the dehumidifier back in

 

 

 

2. Faulty Sensor

 

for normal operation.

F2

Pipe

Tem-

 

 

4.

If the “Error” is still indicated,

 

perature

 

 

 

please contact your nearest

 

Sensor

Mal-

 

 

service center. Call (888) 876-

 

function

 

 

 

5387 for service center

 

 

 

 

 

locations.

 

 

 

 

 

 

CHOOSING THE PROPER LOCATION

Use the dehumidifier:

in the basement to help prevent moisture damage.

in the kitchen, laundry room, bathroom, and spa/exercise areas that have exces- sive moisture.

to prevent moisture damage anywhere books or valuables are stored.

during construction or remodeling to reduce drying time for drywall and paint. However, check and clean filter often.

AUTOMATIC SHUT OFF

When the bucket is full, or when the bucket has been removed, the compres- sor will automatically stop. The fan will continue to run to dehumidify for 3 min- utes. Then the Bucket Full indicator will flash and you will hear a ten second audible alarm.

The bucket must be placed in the proper position for the dehumidifier to work. The Bucket Full light will flash and the dehumidifier will not run if the bucket is not in the proper position. Dehumidifier settings can not be changed when the bucket is not in its proper position.

The dehumidifier fan will shut off in 3 minutes, once the desired humidity set- ting is reached plus or minus 5% Rela- tive Humidity (RH).

PRODUCT SPECIFICATIONS

ITEM #

 

SG-DEH-70EP-2

 

 

Reference Number

DP2-70EP-03

 

 

 

Moisture Removal per 24 hours

70 Pints per day

(32.9 Liters per day)

 

 

 

 

Power Consumption (W)

745 Watts

 

 

 

Bucket Capacity

 

17 Pints (8 Liters)

 

 

 

Power Source

 

115 V / 60 HZ

 

 

Rated Current (Amps)

7.3A

 

 

Sound Pressure Level dB (L/M/H)

45/47/49 dB(A)

 

 

 

Weight

lbs

47.7

 

 

Dimensions (W x D x H)

15.125” x 11.5” x 24.125”

 

 

 

WARNING

To reduce the risk of fire, electric shock or injury to persons, read the important SAFETY IN-

STRUCTIONS found on page 3 before operating this appliance.

KEY FEATURES

Washable Filter

EnclosureContinuous Drain

Connector Door

Dehumidifier

Power Cord

16 ft. Pump Drain Hose

3 ft. Dehumidifier Hose

Bucket

 

Vertical

Power Cord

Pump

 

Caster

16

5

Image 5
Contents SG-DEH-70EP-2 33 Warranty Table of ContentsPackage Contents Important Cautions for Using Your Dehumidifier Safety InstructionsRecommended Grounding Method Installing Your DehumidifierElectrical Requirements External Vertical Pump Product Specifications Error CodesKEY Features SG-DEH-70EP-2Control Panel Water Disposing Options TroubleshootingOption 1 Emptying Manually Do not Remove the Styrofoam in the BucketInstalling the Gravity Drain Hose Care and Maintenance Using the Drain Pump Using the PumpInstalling the Gravity Drain Hose Option 3 External Vertical Pump Installing the External Pump Installing the External Pump