HP SB manual Specifications, Parameter Typical Maximum

Page 14

Specifications

The following optical specifications describe the warranted characteristics of the unit ( Table 2). Supplementary specifications describe the typical non-warranted performance of the unit (Table 3 and Table 4).

Table 2: Optical Specifications

Parameter

Typical

 

Maximum

 

 

 

 

Insertion loss

 

 

 

single-mode1

0.4 dB

 

0.7 dB

multimode1

0.3 dB

 

0.6 dB

 

 

 

 

Return loss

 

 

 

single-mode2standard/analog

65 dB/>65 dB

 

60 dB/65 dB (minimum)

multimode3 standard/analog

25 dB/35 dB

 

20 dB/30 dB (minimum)

 

 

 

 

Polarization dependent loss (single-mode)

0.02 dB

 

0.05 dB

 

 

 

 

Insertion loss stability4

±0.03 dB

 

±0.05 dB

 

 

 

 

Repeatability5

 

 

 

sequential switching

±0.003 dB

 

±0.005 dB

random switching

±0.01 dB

 

±0.025 dB

 

 

 

 

Crosstalk (single-mode)

-100 dB

 

-80 dB

 

 

 

 

Input power (continuous wave)

300 mW

 

 

 

 

 

Channel options

 

 

 

front-panel FC or ST connectors

 

20 (maximum)

front-panel SC connectors

 

24 (maximum)

5 m rear-panel pigtail

 

48 (maximum)

 

 

 

 

Switching time

 

 

 

one channel

 

300 ms (typical)

each additional channel

 

+12 ms (typical)

 

 

 

 

1Insertion loss does not include connectors. Include 0.2 dB (typical), 0.5 dB (maximum) for each connector.

2Excluding connectors.

3Values shown for 62.5 µm diameter maximum fiber core.

4Drift of any channel relative to one assigned reference channel at ±3 °C deviation of ambient temperature over a seven-day period.

5Optimum repeatability after one hour warm-up.

General Information and Specifications – 9

Image 14
Contents SB Series Fiberoptic Switch User’s ManualPage Contents Programming Guide SD000153 Rev. J May Safety Information, Instructions, and Symbols Safety InformationOperating the Unit Safety InstructionsBefore Initializing and Operating the Unit Safety Proceeding Safety SymbolsSymbol Compliance CE ComplianceGeneral Information General Information and SpecificationsSingle-Common SB-C Switch Configuration Dual-Common SB-D Switch Configuration Single Step Dual Common SB-E Switch ConfigurationStandard Accessories Dual-Common Blocking SB-F Switch ConfigurationKey Features Optional AccessoriesSpecifications Parameter Typical MaximumEnvironmental ElectricalPhysical Initial Inspection Getting StartedBefore Initializing and Operating the Unit Operating EnvironmentStoring and Shipping Cleaning Connectors Installing the Switch Connector Cleaning connector type can varyOperating Keys Operating and Maintenance InstructionsFront Panel Key DescriptionRear Panel External Switch Module ConnectionsExternal Switch Module without TTL Input Controls External Switch Module with TTL Input Controls Sample Driver Application Electrical Equivalent of DriverPowering Up the Switch Using and Selecting a ChannelControlling the Drivers Setting the Gpib AddressSetting the Interface Command Set for SC and SX Switches Controlling the Switch Remotely by RS232 Interface Controlling the Switch LocallyControlling the Switch Remotely by Gpib Interface Print #1, CLOSE? Input #1,A$ Print A$ END Calibrating the SwitchMaintaining the Switch Operating and Maintenance Instructions Programming Guide Gpib Pin AssignmentRS232 Pin Assignment RS232 Interface SpecificationsGpib Interface Functions Mnemonic FunctionCommand Parser Rules Operation and Query CommandsName Symbol Pin Number Signal Direction RS232 Driver Pin AssignmentClose Set Optical Channel Operation CommandsReset XDR i k Driver ControlQuery Commands Drivers Error NumberLast Number Error LearnStatus Register Status Reporting and Service Request ControlCondition Register SRQ Mask Register Bit Gpib Programming ExamplesSRQ Mask Register Sending Commands Serial Polling the Status RegisterLearn Query LRN? Generating a Service Request InterruptRS232 Programming Examples Reading the Status Register Setting the Interface Command SetQuerying Status Syntax Function SC Series Switch Command Set SCXXX-0XXX ModelsSX Series Switch Command Set Bit MessageRQS Busy Normal BAD Data Unit Failure