Sterling STT 1600 Temperature Measurement Regeneration Heater Defective, Error Bypass Flap

Page 43

SM2-630

Dehumidified Air Dryer

Check the blower.

Vacuum sensor defective.

Temperature Measurement Regeneration Heater Defective

Check the cables and the sensor.

Check the power supply.

Short circuit check.

Excess Temperature Regeneration Heater

The regeneration temperature is too high.

Check the safety temperature limiter.

Sterling Service.

Insufficient Temperature Regeneration Heater

The regeneration temperature is too low.

Check the regeneration heater.

The Safety Switch Regeneration Heater Has Been Actuated

Check the heater.

Check the fuses.

Short circuit check of the heater.

Error Bypass Flap

The bypass flap does not close or closes too slowly.

Check the bypass flap.

Error Valve Block

The valve block has not reached the proper position. The main switch is placed in the off position.

Check the position of the valve block. Press the “ACK” key and put the main switch in the on positi- on immediately. If the valve block has not reached the correct position within 1 minute, the main switch is again placed in the off position.

Sterling Service.

Temperature Measurement Outgoing Air Defective

Check cables and sensor.

Temperature Measurement Return Air Defective

Check cables and sensor.

Excess Temperature Return Air

Check cables and sensor.

Check the return air cooler.

Error and error correction 4-7

Image 43
Contents Sterling Material Processing Parts and Service Department Edition 11/02 Order confirmation number STT Sterling Material ProcessingSTT Table of Contents Transport, Assembly and Storage Spare parts list Dehumidified Air Dryer General InformationGeneral Information Dehumidified Air Dryer Legal basis Dehumidified Air Dryer Explanations and informationFields of applications Safety instructions Safety instructionsAssembly Dehumidified Air Dryer For your safetyGeneral Operation Maintenance Dehumidified Air Dryer For the safety of the devices Dehumidified Air Dryer Start-up Start-upKey assignment STT Control systemIndicator lamp messages STT Flow chartOperation statuses STT Switching on the dryerSTT Viewing the software-version PasswordsLogout LoginEdit Dryer on/off Timer on/offSTT Basic parameters Turning the devices on/offSTT Dew point max STT Entering dryer valuesRegeneration Heater Act Used air ActReturn air cooler Act Return air cooler TargetHopper entry X Target STT Entering hopper valuesHopper entry X Act Granules Act. C F Granules Target % = C FSTT Observing processing status Valve block moved in/moved out/errorDate STT Setting date and timeTime Contrast STT Viewing/changing language and contrastLanguage Parameters STT Changing parametersSelect Parameters Run on time drying blower -- 300 secXX on 0000 OFF 0000 XX = day Mo-Su STT Setting the timerExample Select Main menu STT Starting continuous operation#.## h STT Viewing system runtimeSelect System runtime System runtimeSTT Switching the dryer off Error and error correction Error and error correctionLED Alarm View Delete NumberTotal messages Waiting messagesOverflow warning On/Off OverflowSafety Switch Drying Blower Has Been Actuated Main Switch is OffSafety Temperature Limiter has been Activated Safety Switch Regeneration Blower Has Been ActuatedSafety Switch Regeneration Heater Has Been Actuated Temperature Measurement Regeneration Heater DefectiveExcess Temperature Regeneration Heater Insufficient Temperature Regeneration HeaterSafety Switch Drying Heater Temperature Measurement Drying Heater DefectiveExcess Temperature Drying Heater Insufficient Temperature Drying HeaterExcess Temperature Granules Hopper Temperature Measurement Granules Defective HopperValve Error Hopper Maintenance MaintenanceSTT STT Maintenance intervals STT Cleaning/renewing the air filters Return air filter/Regeneration air filter Filter of the electrical cabinet STT Tensioning the V-belts Regeneration Blower Drying Blower Disposing of the drying agent Servicing the accessoriesHigh-pressure blowers with frequency converter operation STT Changing the battery of the control system STT STT Resetting the control values Functional description Functional descriptionSTT Dryer Dew point dependent regeneration switch optionalSTT Drying hopper optional STT Return air cooler optional Automatic motor flaps optional STT Hopper heaters optionalConnection to a pneumatic conveying system optional Transport, Assembly and Storage Transport, Assembly and StorageWith a fork lift truck Dehumidified Air Dryer Transport and PackingWith a workshop crane Storage Dehumidified Air Dryer AssemblyAssembly instructions Assembly instructionsAssembly instructions Füllstand Trocknungsmittel Filling level drying agent STT Filling up the drying cellsSTT Connection of the air coolers optional STT Electrical connection Optional Equipment Technical DataTechnical Data Basic EquipmentDimension sheet Spare parts list Spare parts list99716 Ball bearing 05190 Valve stem 86363 Spindle motor 24 100 STT Flaps optional Switching Cabinet and Operating UnitControl Hopper heatersElectrical manual Electrical manualAccessories AccessoriesAccessories Entering values on the OP 7 Entering Values Entering Numerical Values Entering Alphanumeric Values Step Procedure Entering Symbolic Values Accessories Flap control with Fuzzy-Logic Control unit flap Flap control with Fuzzy-Logic
Related manuals
Manual 88 pages 53.58 Kb

STT 1600 specifications

The Sterling STT 1600 is a robust and versatile machine known for its efficiency and performance in various applications, particularly in the field of material handling and transportation. Designed with cutting-edge technology and a focus on user ergonomics, the STT 1600 stands out in its category for its impressive features and specifications.

One of the key characteristics of the STT 1600 is its powerful engine, which provides tremendous torque and horsepower, allowing it to handle heavy loads with ease. This model is equipped with a fuel-efficient diesel engine that meets the latest emissions standards, ensuring both performance and environmental compliance. The engine’s advanced fuel management system optimizes consumption, making it an economical choice for businesses that rely on durability and cost-effectiveness.

The STT 1600 features a heavy-duty chassis that enhances stability and strength during operation. This construction ensures that the machine can withstand rigorous use in tough environments, whether for construction, warehousing, or logistics. Additionally, the equipment boasts a maximum lifting capacity that accommodates a wide variety of materials, ranging from pallets to larger equipment, making it highly versatile for different industries.

Technologically, the Sterling STT 1600 is equipped with state-of-the-art hydraulics that provide smooth and precise movement of the lifting mechanism. This includes a hydraulic lift that allows for optimal height adjustments with minimal effort from the operator. The system is designed for quick response times, which is crucial for enhancing operational efficiency in fast-paced environments.

The ergonomic design of the cab focuses on the operator's comfort and usability. It features adjustable seating, intuitive controls, and enhanced visibility, reducing fatigue and improving safety during extended shifts. Furthermore, the machine includes an advanced safety system with sensors and emergency stop mechanisms to protect both operators and on-site personnel.

Maintenance is simplified with the STT 1600, as easy access points allow for quick inspections and repairs, minimizing downtime. The overall build quality and design reflect a commitment to longevity, making the Sterling STT 1600 a trusted choice for businesses looking to invest in reliable and high-performing machinery. In summary, the Sterling STT 1600 represents a perfect blend of power, efficiency, and technological advancements, making it an ideal solution for material handling challenges.