2-Stage Burner Easy Setup
The
move the pin to the third setting to run. The burner will then switch from low to high fire automatically as needed. The burner is also mounted on a double hinge making it easy to service as needed.
Specifications
Model Number |
| OH6FX072DV4R |
| |
Heating Capacity | Low Capacity | High Capacity | ||
| Low Fire | High Fire | Low Fire | High Fire |
Heat Input Rate (BTUH) | 70,000 | 85,000 | 85,000 | 106,250 |
Output BTUH1 | 61,500 | 74,000 | 74,000 | 91,000 |
Seasonal Efficiency2 (AFUE) |
| 87.3 |
| 86.4 |
Largest Recommended A/C3 |
| 4 Tons |
| 4 Tons |
Nominal Temperature Rise | 64° | 64° | 64° | 64° |
Dimensions (inches) H x W x D |
| 45” x 20” x 30” |
| |
Nominal Flue Outlet Diameter |
| 5” |
|
|
Approximate Shipping Weight (lbs.) |
| 250 |
|
|
Quantity and Size of Permanent Filters |
| (1) |
| |
Electrical Requirements |
| 120 / 60 / 1 |
| |
Maximum Fuse Size /ECM |
| 15 |
|
|
Total Current (AMPS) /ECM |
| 12.3 |
|
|
Height from Floor to Center of Flue |
|
|
| |
Supply Air Outlet Size W x D |
| 18” x 19” |
|
|
Return Air Ductwork Connection |
|
| ||
Flange Size on Filter D x H |
|
| ||
|
|
|
| |
Return Air Inlet Opening Size in Side |
| 23” x 14” |
|
|
Casing (to be |
|
|
| |
|
|
|
| |
| Accessory Items |
|
| |
Programmable Thermostat |
| 350866 |
|
|
1.Output based on Annual Fuel Utilization Efficiency rated by manufacturer.
2.Seasonal Efficiency (also called AFUE - Annual Fuel Utilization Efficiency) ratings are based on tests following the U.S. Department of Energy test procedures.
3.To permit largest recommended air conditioning (at .5 static pressure), selection of the highest motor speed is required.
R
Form No. PL81410041003 - 1/07 - 10Ms Printed in the U.S.A.
© 2007 Thermo Poducts, LLC - North Judson, IN Phone: