QuickSpecs
HP StorageWorks Modular Smart Array 30 Single Bus or Dual Bus Enclosures
Technical Specifications
Protocol Support | Wide Ultra320 (LVD) |
|
| Wide Ultra3 (LVD) |
|
| Wide Ultra2 (LVD) |
|
O/S Support | Defined by specific HP array controller or SCSI adapter used; please refer to the QuickSpecs | |
| and/or User Guide of the specific array controller or SCSI adapter | |
Dimensions (HxWxD) | Rack | 5.2 x 19 x 20.5 in (13.1 x 47.88 x 51.66 cm) |
Shipping Dimensions | Rack | 34.25 x 14.5 x 31.25 in (86.31 x 36.54 x 78.75 cm) |
(HxWxD) |
|
|
Weight | Rack | 68 lb (30.9 kg) |
LED Indicators (on front | EMU Status LED (left) |
|
panel) | Enclosure Power LED (middle) | |
| Fault LED (right) |
|
Drive LED Indicators | Drive LED (top) |
|
(on drive trays) | On Line LED (middle) |
|
| Drive Failure LED (bottom) | |
Enclosure LED | I/O Module (top) |
|
Indicators (back of unit) | EMU (middle) |
|
| Power supplies (bottom) |
|
Input Requirements | Nominal Line Voltage | 110 to 240 V AC |
| Range Line Voltage | 90 to 264 V AC |
| Line Frequency | 47 to 63 Hz |
| Typical Input Current | 2.3A at 120 V AC |
Relative Humidity (non- Operating | 10% to 90% | |
condensing) | Shipping | 5% to 90% |
I/O Module Connector | Very High Density Cable Interconnect (VHDCI) | |
Power | 377 Watts per supply (load) | |
BTU (220 volts) | Single power supply 14 | 1164 BTUs/hour |
| drives |
|
| Single power supply 5 | 536 BTUs/hour |
| drives |
|
| Single power supply 1 | 273 BTUs/hour |
| drive |
|
| Dual power supply 14 | 1232 BTUs/hour |
| drives |
|
| Dual power supply 5 | 625 BTUs/hour |
| drives |
|
| Dual power supply 1 | 352 BTUs/hour |
| drive |
|
Temperature Range | Operating | 50° to 94° F (10° to 35° C°) |
| Shipping |
NOTE: To maintain proper cooling and airflow, a drive blank or drive must occupy all bays during operation.
DA - 11738 Worldwide QuickSpecs — Version 25 — 6.8.2007 | Page 11 |