HP DL585 manual Technical Specifications

Page 40

QuickSpecs

HP ProLiant DL585

Technical Specifications

System Unit Rack

Chassis Footprint

6.94 x 19 x 26.5 in (17.6 x 48.3 x 67.3 cm)

 

 

(HxWxD)

 

 

 

 

 

Weight

66 lb (29.9 kg)

 

 

 

 

No hard drives installed,

 

 

 

 

 

one power supply

 

 

 

 

 

Input Requirements

Rated Input Voltage

100 to 120 VAC/200 to 240 VAC

 

 

 

Rated Input Frequency

50 to 60 Hz

 

 

 

Input Power

1135W @ 110 VAC/1125W @ 220 VAC

 

 

 

Rated Input Current

12A (100 VAC), 9.8A (120 VAC), 4.9A (220

 

 

 

 

VAC)

 

 

Max BTU Rating

4000 BTU

 

 

 

 

Power Specifications

To review typical system power ratings use the Active Answers Power

 

 

 

Calculator which is available via the online tool located at URL:

 

 

 

http://h30099.www3.hp.com/configurator/powercalcs.asp.

 

 

 

To drill down to calculators:

 

 

 

 

 

Click on: "ProLiant Servers"

 

 

 

Click on the Server of interest. Example: DL585

 

 

 

Click on: "Power Calculator" link (You may need to scroll down to see

 

 

 

it.)

 

 

 

 

Power Supply Output

Rated Steady-State Power

800W/800W (lowline/highline)

 

 

Power (per power supply)

Maximum Peak Power

800W/800W (lowline/highline)

 

 

Temperature Range

Operating

50° to 95° F (10° to 35° C)

 

 

 

Non-operating

-20° to 140° F (-29° to 60° C)

 

 

 

Shipping

-22° to 122° F (-30° to 50° C)

 

 

Relative Humidity

Operating

10% to 70%

 

 

(non-condensing)

Non-operating

5% to 95%

 

 

 

 

 

Maximum Wet Bulb

101.7° F (38.7° C)

 

 

 

 

Temperature

 

 

 

 

 

Acoustic Noise

NOTE: Listed are the declared A-weighted sound power levels LWAd and the

 

 

 

declared average bystander position sound pressure levels LpAm when

 

 

 

operating in a 23° C ambient environment. Noise emissions were measured

 

 

 

in accordance with ECMA 74 and declared in accordance with ECMA 109.

 

 

 

Idle (Fixed Disk Drives

 

 

 

 

 

Spinning)

 

 

 

 

 

L WAd (BELS)

7.3

 

 

 

 

L pAm (dBA)

55

 

 

 

 

Operating Minimum

 

 

 

 

 

(Random Seeks to Fixed

 

 

 

 

 

Disks)

 

 

 

 

 

L WAd (BELS)

7.3

 

 

 

 

L pAm (dBA)

55

 

 

 

 

NOTE: These values apply to 4U rack configuration with the Health Driver

 

 

 

Fan Control active. Configuration tested included 2 AMD Opteron 2.2 GHz

 

 

 

processors, 1 15 krpm hard drive, 2 power supplies, 4 memory/IO fans and

 

 

 

4 CPU fans.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DA - 11902 Worldwide — Version 29 — May 5, 2005

Page 40

Image 40
Contents QuickSpecs OverviewAt a Glance Standard Features Manageability StorageMaximum Internal Storage TypeForm Factor ProLiant EssentialsFoundation Pack SoftwareIndustry Standard ComplianceServiceability AvailabilityPower Supply SecuritySystem Fans Required CablingRack Mounting Rack 10000 series CabinetsRequirements QuickSpecs Solutions SolutionsTypical Usage Models DL585R01 O2.2 GHz Processors DL585R01 O2.4 GHz ProcessorsCountry Code Key Models Configuration Information Factory Integrated ModelsFactory Integrated Models ship with Base Memory Optical DrivesOptions ProLiant DL585 Unique OptionsWGR Memory DIMMs Ultra320 Scsi Universal Hot PlugStorage Controllers Rack-mount Flat Panel Monitors DAT Drives External, Rack-Mount and Array Module Tape Autoloaders DAT Autoloader HP StorageWorks 1/8 Tape AutoloaderHP StorageWorks SSL1016 Tape Autoloader Sdlt 600 technologyHP StorageWorks MSL5026S2 Tape Library HP StorageWorks MSL5052S2 Tape LibraryHP StorageWorks MSL5060 Tape Library HP StorageWorks ESL E-Series Tape LibrariesHP StorageWorks 9.1 GB High-end Optical Jukeboxes HP StorageWorks 9.1 GB Mid-range Optical JukeboxesHP StorageWorks Ultra Density Optical Storage Cluster Options HP StorageWorks Modular Smart Array 1500 cs HP StorageWorks Modular Smart ArrayUPS and PDU Power Specifications for UPS and PDU unitsStorageWorks Options Cord MatrixUPS R3000 XR USB OptionsCustom Builder Third Party Rack KitTelco Rack Support HP Rack 5000 SeriesRack Options for HP Rack 10000 Series Options/index.htmlHardware Services On-site Service Service and SupportInstallation & Start-up Services Support Plus Memory Example #2 Maximum Memory Configuration Storage Quantity Position Supported ControllerUltra320 Hot Pluggable Drives Quantity Position Supported Controller InchTape Drives, Tape Autoloaders, and Tape Libraries HP StorageWorks Tape Drives, ExternalMount Tape Drive Enclosures HP StorageWorksPower Specifications Power Cords Power Cord Part Number Country Technical Specifications Access Times typical DimensionsShipping Dimensions Shipping WeightAmbient Temperature Option Kit ContentsLoading Mechanism Typical Data Transfer RateUpgradeability ILO Advanced FeaturesArchitecture Video SupportBattery-Backed Write Online ConfigurationConnector Drives SupportedQuickSpecs