HP NC510C manual Specifications, CX4 Twin-axial cable, General specifications, Compliance

Page 10

Specifications

In this section

 

CX4 Twin-axial cable

10

General specifications

10

Compliance

10

Power and environmental specifications

11

CX4 connector pinout description

11

CX4 Twin-axial cable

The NC510C adapter uses a 10Base-CX4 copper interface to deliver Gigabit Ethernet over four twin- axial copper cable pairs as specified in the IEEE 802.3ak standard. For troubleshooting and other information about cabling, see the CX4 connector pinout description (on page 11).

General specifications

General

Value

specifications

 

 

 

Controller

NETXEN NX2031

 

 

Data rate

10 Gbps, full-duplex

 

 

PCI bus

8 Lane (x8) PCI Express, compatible with x4 and x8 bus widths

 

 

Cable connector

4x InfiniBand® (SFF-8470)

 

 

Cable distance

15 meters with CX4 x4 twin-axial cable

 

 

Dimensions (LxW)

6.6 x 2.5 in (16.5 x 6.4 cm) without bracket

 

 

Compliance

Compliance

Standard

 

 

IEEE

802.1p (QoS), 802.1Q (VLANs), 802.3ae (10 Gigabit Ethernet), 802.3ak (CX4),

 

802.3x (flow control)

 

 

Safety

UL Mark (US and Canada)

 

EN 60950

 

 

Emissions

FCC Class A, VCCI Class A, BSMI Class A, CISPR 22 Class A, ACA Class A,

 

EN55022 Class A, EN55024-1, ICES-003 Class A, MIC Class A

Specifications 10

Image 10
Contents HP NC510C PCle 10 Gigabit Server Adapter User Guide Part Number 437524-00B February 2007 Second EditionAudience assumptions Contents Where to go for additional help Technician notesHP contact information Introduction LED indicatorsOverview LED indicator Status Description Installation overview Installing an adapterPreventing electrostatic discharge Installing an adapter in a server Installing a low profile bracketCX4 Twin-axial cable SpecificationsGeneral specifications CompliancePower Value Environmental Specifications Power and environmental specificationsCX4 connector pinout description Pin Signal name Connector pinSpecifications Class a equipment Regulatory compliance noticesRegulatory compliance identification numbers ModificationsCanadian notice Regulatory compliance notices Electrostatic discharge Grounding methods to prevent electrostatic dischargeAcronyms and abbreviations Index