HP Integrated Lights-Out manual Getglobalsettings, Modnetworksettings Runtime Errors

Page 293

Remote Insight Command Language 293

SEC_WINS_SERVER specifies the IP address of the secondary WINS server. This parameter is only relevant if the DHCP-assigned WINS server address feature is disabled. If an empty string is entered, the current value is deleted.

STATIC_ROUTE_1, STATIC_ROUTE_2, and STATIC_ROUTE_3 are used to specify the destination and gateway IP addresses of the static routes. The following two parameters are used within the static route commands. If an empty string is entered, the current value is deleted.

DEST specifies the destination IP addresses of the static route. This parameter is only relevant if the DHCP-assigned static route feature is disabled. If an empty string is entered, the current value is deleted.

GATEWAY specifies the gateway IP addresses of the static route. This parameter is only relevant if the DHCP-assigned static route feature is disabled. If an empty string is entered, the current value is deleted.

WEB_AGENT_IP_ADDRESS specifies the address for the Web-enabled agents. If an empty string is entered, the current value is deleted.

MOD_NETWORK_SETTINGS Runtime Errors

The possible MOD_NETWORK_SETTINGS error messages include:

RIB information is open for read-only access. Write access is required for this operation.

User does not have correct privilege for action. CONFIG_ILO_PRIV required.

GET_GLOBAL_SETTINGS

The GET_GLOBAL_SETTINGS command requests the respective iLO global settings. For this command to parse correctly, the command must appear within a RIB_INFO command block, and RIB_INFO MODE can be set to read or write.

GET_GLOBAL_SETTINGS Parameters

None

Image 293
Contents HP Integrated Lights-Out User Guide Audience Assumptions Contents User Guide Integrated Lights-Out ILO Security 135 Certificate Services 189 Insight Manager 7 Integration 223 Lights-Out DOS Utility 249 Login Modglobalsettings Moddiagport Settings ILO Parameters 331 Contents Technical Support 397 This Section Operational OverviewNew in This Version Network Connection Overview Usage ModelSupported Server Operating System Software Supported Browsers Configuring Linux Font Size Linux Browser ConfigurationPage ILO Configuration Options Configuring iLOILO Rbsu Browser-Based Setup Scripted Setup Installing iLO Device DriversILO Pre-requisite Files for Microsoft Installing or Updating the iLO Drivers for MicrosoftSelect Software and Drivers ILO Pre-Requisite Files for NetWare Installing or Updating iLO Drivers for NetWareNovell NetWare Server Driver Support Instaling or Updating iLO Linux and SuSE Drivers Red Hat Linux and SuSE Linux Server Driver SupportILO Pre-requisite Files for Red Hat and SuSE Linux Files Enabling iLO Advanced Functionality ILO Advanced License Options Activating iLO Advanced Features Using a BrowserILO Advanced Evaluation License User Guide Integrated Lights-Out Activating iLO Advanced Using Scripting ProLiant BL p-Class ConfigurationProLiant BL p-Class User Requirements Static IP Bay ConfigurationConfiguring Static IP Bay Settings Configuring a ProLiant BL p-Class Blade EnclosureUser Guide Integrated Lights-Out ProLiant BL p-Class Advanced Configuration Parameters ProLiant BL p-Class Standard Configuration ParametersRibcl Rackinfo Commands Enable iLO IP Address AssignmentModifying Static IP Bay Configuration Settings Ribcl Rackinfo Command ExamplesGetting Static IP Bay Configuration Settings Integration with Riloe II Accessory Boards Logging in to iLO for the First Time Using iLOLogging in to iLO for the First Time Using a Browser Using iLO User Guide Integrated Lights-Out Using iLO Help Progressive Delays for Failed Browser Login AttemptsILO Status System StatusStatus Summary Server Status ILO Event Log Integrated Management Log Post Diagnostic Results for the Host Server Server and iLO DiagnosticsVirtual NMI Button Nvram Environment Variables ListingILO Self-Test Results Remote Console Option Remote ConsoleRemote Console Information Option Recommended Client Settings Enhanced Features of the Remote ConsoleOptimizing Performance for Graphical Remote Console Display PropertiesRecommended Server Settings Remote Console Linux SettingsRemote Console Mouse PropertiesMicrosoft Windows Server 2003 Settings Microsoft Windows NT 4.0 and Windows 2000 SettingsRemote Console Hot Keys Red Hat Linux and SuSE Linux Server SettingsNovell NetWare Settings Supported Hot Keys Remote Console Single-Cursor Single- and Dual-Cursor Modes for Graphical Remote ConsoleRemote Console Dual-Cursor Virtual Devices Virtual Power Using iLO Virtual Media MS-DOS Operating System USB SupportUSB USB CD USB CD2 Select Local Floppy Drive Using iLO Virtual Media DevicesILO Virtual Floppy Click Connect Access iLO through a browser Connect Click Create Disk Image Select Local CD-ROM Drive ILO Virtual CD-ROMUsing an Image File Virtual Media CD-ROM Operating System Notes Mounting USB Virtual Media CD in NetWare Mount /dev/scd0 /mnt/cdrom -t iso9660 Virtual Media Composite Device Support Select Local Floppy Drive Virtual Media Scripting Virtual Media Applet TimeoutILO Virtual Media Privilege Command Line Input Result Virtual Media Image Files Scripting Web Server RequirementsCGI Helper Application Virtual Indicators Windows EMS Console Virtual Serial PortVirtual Serial Port and Linux Security InformationLinux End-to-End Support AdministrationUser Administration Adding a New User Click View/Modify User Viewing or Modifying an Existing Users SettingsDeleting a User Global SettingsClick Global Settings User Guide Integrated Lights-Out Network Settings Click Network Settings Using iLO ILO Diagnostic Port Configuration Parameters Recovering from a Failed iLO Firmware Update SNMP/Insight Manager SettingsEnabling Snmp Alerts Generating Test Alerts Click Apply SettingsConfigure Insight Manager Integration Upgrade iLO FirmwareClick Send firmware image Licensing Certificate AdministrationProLiant BL p-Class Advanced Management Directory SettingsUser Guide Integrated Lights-Out Rack Settings Server Blade Management Module Power Management ModuleILO Control of ProLiant BL p-Class Server LEDs Redundant Power Management ModuleHot-Plug Keyboard Insufficient Power NotificationKeyboard Definitions Server Post TrackingHot-Plug Keyboard Recommended Usage Hot-Plug Keyboard TroubleshootingUser Guide Integrated Lights-Out Terminal Services Client Requirements Terminal Services Pass-Through OptionWindows RDP Pass-Through Service Terminal Services Pass-Through Installation Windows 2000 Terminal Services Port Change Enabling the Terminal Services Pass-Through OptionTerminal Services Warning Message Terminal Services Pass-Through StatusTerminal Services Button Display Remote Console and Terminal Services ClientsManagerMultifunction Adapters Terminal Services TroubleshootingComputerPropertiesRemoteRemote Desktop ViewerApplication HP ProLiant Essentials Rapid Deployment Pack IntegrationTelnet Support Telnet Simple Command Set Using TelnetTelnet Security Supported Key SequencesILO VT100+ Key Map Altk Altlowerj Linux Codes for the F-Keys VT100+ Codes for the F-KeysSecure Shell Using Secure ShellUsing SSH Using PuTTY ILO Supported SSH FeaturesUsing OpenSSH ILO Shared Network Port Requirements ILO Shared Network PortILO Shared Management Port Features and Restrictions Enabling the iLO Shared Network Port Feature Select AdministrationNetwork Settings Re-enabling the Dedicated iLO Management Port Select NetworkNICTCP/IP, and press the Enter key Command Line InterfaceHelp CLI CommandsEscape Remcons PowerExit VspPage General Security Guidelines Security FeaturesILO Security Encryption ILO Security Override Switch AdministrationUser Accounts Privileges Login SecurityGlobal Security Settings Password GuidelinesCertificates Securing Rbsu Page Benefits of Directory Integration Directory ServicesFeatures Supported by Directory Integration Installing Directory Services Schema Documentation Directory Services Support Schema Required Software Schema Installer EDirectory Installation PrerequisitesSchema Preview Setup Directory Services 151 Results Management Snap-In InstallerActive Directory Installation Prerequisites Directory Services for Active DirectoryDirectory Services Preparation for Active Directory Start MMC Install the Active Directory Schema snap-in in MMC Snap-In Installation and Initialization for Active Directory Directory Services 157 User Guide Integrated Lights-Out Directory Services 159 User Guide Integrated Lights-Out Directory Services 161 Directory Services Objects Active Directory Snap-Ins HP Devices Active Directory Role Restrictions MembersUser Guide Integrated Lights-Out Time Restrictions Enforced Client IP Address or DNS Name Access Remove Active Directory Lights-Out Management Snap-in Installation and Initialization for eDirectory Directory Services for eDirectoryUser Guide Integrated Lights-Out Directory Services 173 Apply Directory Services 175 Directory Services Objects for eDirectory Role Managed Devices Role Restrictions EDirectory Role Restrictions Time Restrictions Delete Lights-Out Management Directory Services 183 Configuring Directory Settings Directory Services 185 Directory Tests User Login Using Directory Services User Guide Integrated Lights-Out Installing Certificate Services Certificate ServicesIntroduction to Certificate Services Configuring Automatic Certificate Request Verifying Directory ServicesCertificate Services 191 Page Introduction to Directory-Enabled Remote Management Directory-Enabled Remote ManagementUsing Bulk Import Tools Using Existing Groups Using Multiple Roles AdminUserAdminRole Server UserRole Role Time Restrictions Creating Roles to Follow Organizational StructureRestricting Roles DNS-Based Restrictions IP Address Range RestrictionsIP Address and Subnet Mask Restrictions Role Address Restrictions How Directory Login Restrictions are EnforcedUser Address Restrictions How User Time Restrictions are EnforcedCreating Multiple Restrictions and Roles Directory-Enabled Remote Management 203 User Guide Integrated Lights-Out Introduction to Lights-Out Migration Utilities Lights-Out Directories Migration UtilitiesCompatibility Pre-Migration ChecklistHP Lights-Out Directory Package Finding Management Processors Hpqlomig OperationLights-Out Directories Migration Utilities 209 Upgrading Firmware on Management Processors Enter your Login NamePassword and click FindLights-Out Directories Migration Utilities 211 Naming Management Processors Select either Use Network Address or Create Name Using IndexConfiguring Directories Browse Click Update DirectorySetting Up Management Processors for Directories Click Configure Hpqlomgc Operation Firmware version is validated and updated if necessary Launching Hpqlomgc Using Application LaunchManagement processor directory settings are updated Directory is updatedLights-Out Directories Migration Utilities 219 Hpqlomgc Command Language Iloconfig Page Integrating iLO with Insight Manager Insight Manager 7 IntegrationIdentification and Association Functional OverviewLinks StatusQueries Configuring Identification of iLO Insight Manager 7 Integration 227 Receiving Snmp Alerts in Insight ManagerPort Matching Insight Manager 7 Integration 229 User Guide Integrated Lights-Out ProLiant BL p-Class Rack Visualization User Guide Integrated Lights-Out Integrating iLO with Systems Insight Manager Systems Insight Manager IntegrationSystems Insight Manager Functional Overview System Insight Manager Status System Insight Manager Identification and AssociationSystem Insight Manager Systems Lists Configuring System Insight Manager Identification of iLOSystem Insight Manager Links Receiving Snmp Alerts in Systems Insight Manager System Insight Manager Port Matching Systems Insight Manager Integration 239 Page Lights-Out Configuration Utility Group Administration and iLO Scripting\PROGRAM FILES\INSIGHT MANAGER\HP\SYTEMS Select Management Processor and click OK Query Definition in Insight ManagerApplication Launch Using Insight Manager Create a Customized List Create a Custom CommandClick ToolsCustom CommandsNew Custom Command Click either Schedule or Run Now Create a TaskLights-Out Configuration Utility Parameters Batch Processing Using the Lights-Out Configuration UtilityCpqlocfg Overview of the Lights-Out DOS Utility Lights-Out DOS UtilityCpqlodos General Guidelines Command Line ArgumentsCpqlodos Recommended Usage Lights-Out DOS Utility 251 Cpqlodos Parameter Ribcl XML Commands for CpqlodosCpqlodos Runtime Error Adduser Parameters Adduser Runtime ErrorsSetlicense Parameter Setlicense Runtime ErrorsXML Enhancements Using Perl with the XML Scripting InterfacePerl Scripting XML script modification Opening an SSL Connection Sending the XML Header and Script Body Perl Scripting 259 User Guide Integrated Lights-Out Hponcfg Supported Operating Systems Hponcfg Online Configuration UtilityHponcfg Hponcfg Requirements Hponcfg Installation and UsageLinux Server Installation Windows Server InstallationUsing Hponcfg Hponcfg Command Line ParametersHponcfg Usage Model Obtaining an Entire ConfigurationSample adduser.xml input file Creating a User AccountHponcfg Online Configuration Utility Page Remote Insight Command Language Ribcl and ProLiant BL p-Class Servers Overview of the Remote Insight Board Command LanguageData Types Ribcl Sample Scripts Ribcl General GuidelinesXML Header String Response DefinitionsSpecific String Boolean StringRibcl Parameter Ribcl Runtime ErrorsRibcl Login Runtime Errors LoginLogin Parameters Userinfo Parameter Userinfo Runtime ErrorUserinfo Adduser Parameters AdduserRemote Insight Command Language Adduser Runtime Errors Deleteuser Parameter Deleteuser Runtime ErrorsDeleteuser Getuser Parameter Getuser Runtime ErrorsGetuser Getuser Return Messages ModuserModuser Parameters Moduser Runtime Errors Getallusers Getallusers Runtime ErrorGetallusers Parameters Getallusers Return MessagesGetalluserinfo Parameters Getalluserinfo Runtime ErrorsGetalluserinfo Getalluserinfo Return Messages RibinfoRibinfo Runtime Errors ResetribResetrib Parameters Resetrib Runtime ErrorsGetnetworksettings Parameters GetnetworksettingsGetnetworksettings Runtime Errors Getnetworksettings Return MessagesDhcpwinsserver VALUE=Y Regwinsserver VALUE=Y ModnetworksettingsModnetworksettings /RIBINFO Login Ribcl Modnetworksettings Parameters User Guide Integrated Lights-Out Getglobalsettings Parameters GetglobalsettingsModnetworksettings Runtime Errors Getglobalsettings Return Messages ModglobalsettingsGetglobalsettings Runtime Errors Modglobalsettings Parameters User Guide Integrated Lights-Out Remote Insight Command Language Modglobalsettings Runtime Errors GetsnmpimsettingsGetsnmpimsettings Parameters Getsnmpimsettings Runtime ErrorsModsnmpimsettings Parameters ModsnmpimsettingsModsnmpimsettings Runtime Errors Cleareventlog Parameters Cleareventlog Runtime ErrorsCleareventlog Updateribfirmware Runtime Errors UpdateribfirmwareUpdateribfirmware Parameters Getfwversion Getfwversion Runtime ErrorsGetfwversion Parameters Getfwversion Return MessagesHotkeyconfig Parameters HotkeyconfigLicense Hotkeyconfig Runtime ErrorsLicense Parameters License Runtime ErrorsDirinfo Runtime Errors GetdirconfigDirinfo Dirinfo ParametersGetdirconfig Return Messages Getdirconfig ParametersGetdirconfig Runtime Errors Moddirconfig Parameters ModdirconfigRackinfo Moddirconfig Runtime ErrorsRackinfo Parameters Rackinfo Runtime ErrorsModbladerack Modbladerack Parameters Modbladerack Runtime Errors GetdiagportsettingsGetdiagportsettings Parameters Getdiagportsettings Runtime ErrorsModdiagportsettings Parameters ModdiagportsettingsGetdiagportsettings Return Messages Gettopology Moddiagportsettings Runtime ErrorsGettopology Return Message ServerinfoGettopology Parameters Serverinfo Parameter GethostpowerstatusServerinfo Runtime Errors Gethostpowerstatus Parameters SethostpowerGethostpowerstatus Runtime Errors Gethostpowerstatus Return MessagesSethostpower Runtime Errors ResetserverSethostpower Parameters Resetserver Errors Resetserver ParametersPresspwrbtn Presspwrbtn ParametersHoldpwrbtn Runtime Errors Presspwrbtn Runtime ErrorsHoldpwrbtn Holdpwrbtn ParametersColdbootserver Runtime Errors ColdbootserverColdbootserver Parameters Warmbootserver Parameters WarmbootserverWarmbootserver Runtime Errors GetuidstatusGetuidstatus Response UidcontrolGetuidstatus Parameters Insertvirtualmedia Uidcontrol ErrorsUidcontrol Parameters Insertvirtualmedia ParametersInsertvirtualfloppy Runtime Errors Ejectvirtualmedia Parameters Ejectvirtualmedia Runtime ErrorsEjectvirtualmedia Getvmstatus Getvmstatus Runtime ErrorsGetvmstatus Parameters Getvmstatus Return MessagesSetvmstatus Parameters SetvmstatusSetvmstatus Runtime Errors ILO Parameters Table ILO ParametersGlobal Settings ILO Parameters 333 SNMP/Insight Manager Settings ILO Parameters 335 ILO Status Server ID Server Status ParametersServer Name User Administration Parameters Administer User Accounts PasswordRemote Console Access Virtual Power and ResetEnable Lights-Out Functionality Idle Connection Timeout MinutesEnable iLO Rbsu Pass-Through ConfigurationRemote Console Port Configuration Require Login for iLO RbsuShow iLO During Post Remote Console Data EncryptionWeb Server Non-SSL Port Terminal Services PortWeb Server SSL Port Virtual Media PortSerial Command Line Interface Speed bits/second Serial Command Line Interface StatusMinimum Password Length Network Settings ParametersShared Network Port Enable NICTransceiver Speed Autoselect SpeedRegistering with DNS Server Registering with Wins ServerPing Gateway on Startup ILO IP AddressILO Subsystem Name ILO Gateway IP AddressDomain Name Dhcp ServerEnable iLO Snmp Alerts SNMP/Insight Manager Settings ParametersEnable Snmp Pass-Through Snmp Alert DestinationsInsight Manager Web Agent URL ILO Advanced License Activation SettingsLevel of Data Returned ILO Advanced Pack License KeyEnclosure Name Rack NameBay Name BayEnable Automatic Power On Power SourceEnable Rack Alert Logging IML Directory Settings ParametersEnable Local User Accounts Enable Directory AuthenticationLOM Object Password Directory Server AddressClick Start Test Testing Directory SettingsClick Test Settings HP Management Core Ldap OID Classes and Attributes Directory Services SchemaCore Classes Core AttributesHpqRole Core Class DefinitionsHpqTarget HpqPolicy Core Attribute DefinitionsHpqPolicyDN HpqRoleMembershipHpqRoleIPRestrictions HpqRoleIPRestrictionDefaultHpqTargetMembership Directory Services Schema 357 HpqRoleTimeRestrictionLights-Out Management Attributes Lights-Out Management ClassesHpqLOMv100 Lights-Out Management Class DefinitionsLights-Out Management Attribute Definitions HpqLOMRightVirtualMedia HpqLOMRightLoginHpqLOMRightRemoteConsole HpqLOMRightConfigureSettings HpqLOMRightServerResetHpqLOMRightLocalUserAdmin Page Minimum Requirements Troubleshooting iLOILO Post LED Indicators Troubleshooting iLO 365 FEH Code Consistency Check Explanation Event Log EntriesTroubleshooting iLO 367 User Guide Integrated Lights-Out Troubleshooting iLO 369 Hardware and Software Link-Related Issues MS-DOS Error CodesSoftware Login IssuesHardware Directory User Premature Logout Login Name and Password Not AcceptedILO Management Port Not Accessible by Name Inability to Access the Login ILO Rbsu Unavailable after iLO and Server ResetInability to Connect to the iLO Diagnostic Port Inability to Access iLO Using TelnetInability to Connect to iLO after Changing Network Settings Inability to Connect to the iLO Processor through the NIC Firewall Issues Proxy Server Issues Troubleshooting Alert and Trap ProblemsAuthentication Code Error Message ILO Security Override SwitchLocal USB Mouse and Linux Troubleshooting Mouse ProblemsRemote Console Mouse Control Issue Mouse Issue Using SuSE LinuxLinux Remote Console Troubleshooting Remote Console ProblemsEmulating a PS/2 Keyboard in a Headless Server Environment User Guide Integrated Lights-Out Remote Console Text Window not Updating Properly Remote Console Turns Grey or Black Troubleshooting SSH and Telnet ProblemsInitial PuTTY Input Slow PuTTY Client Unresponsive with Shared Network PortTerminal Services Button Is Not Working Troubleshooting Terminal Services ProblemsTerminal Services Proxy Stops Responding SSH Text Support from a Remote Conosle SessionGeneral Guidelines Troubleshooting Video and Monitor ProblemsTelnet Displays Incorrectly in DOS Video Applications not Displaying in the Remote ConsoleTroubleshooting Miscellaneous Problems Troubleshooting Virtual Media ProblemsVirtual Drive Listing Virtual Media Applet has a Red X and Will Not DisplayCookie Order Behavior Cookie Sharing Between Browser Instances and iLOShared Instances Troubleshooting iLO 389 Displaying the Current Session Cookie Preventing Cookie-Related User IssuesILO Network Flash Recovery Inability to Upgrade iLO FirmwareDiagnostic Steps Incorrect Time or Date of the Entries in the Event LogFlash Recovery Process ROMPaq ILO Does Not Respond to SSL Requests Testing SSLRequest New Certificate Resetting iLOServer Name Still Present after Erase Utility is Executed Troubleshooting a Remote HostBefore You Contact HP Technical SupportHP Contact Information User Guide Integrated Lights-Out Acronyms and Abbreviations DAV ILO JVM MTU RDP SSL Page Index LAN Index Uidcontrol