All installations and services must be performed by qualified service personnel.

E. FUEL PIPING

Sizing and installation of fuel lines must be in accordance with Federal, State & Local regulations. Including the National Fuel Gas Code NFPA 54/ANSI-Z233.1 (Latest Edition).

NOTE: These furnaces are designed to be gas piped through the left side or the bottom. For service purposes, it is recommended that the gas union be located inside the furnace when possible.

: Because of the potential of odorant fade, a gas leak may not be detected by smell. If this furnace is installed below grade, contact your gas supplier for a gas detector.

A qualified installer or service person must perform all gas piping and testing. Piping from the natural gas meter to the furnace shall be in accordance with requirements of the local gas utility. Piping from the LP tank to the furnace must follow the recommendations of the gas supplier.

A readily accessible manual shut off valve (certified for the applicable gas) with a non-displaceable rotor member shall be installed within six feet of the gas equipment it serves.

A union or flanged connection shall be provided directly up stream of the burner to allow burner removal. Unions must be of a ground joint type or flange-jointed type using a gasket resistant to the applicable gas. Pipe dope or sealant certified to be resistant to the action of the applicable gases should be used on all threaded joints.

A drip leg must be used on both LP and Natural gas installations prior to the furnace in order to trap oil, condensate and other impurities which might otherwise lodge in the gas valve or plug the burner orifice.

A drip leg shall be provided at the outlet of the gas meter when there is excessive condensation between the gas meter and the furnace. Failure to install a drip leg may void the limited warranty on the furnace.

: All gas pipe connections must be leak tested using methods approved by State, Local and National Fuel Gas Code NFPA 54/ANSI-Z233.1 (Latest Edition). Any leaks must be repaired immediately after turning off the gas supply. A final test for gas leakage must be made after purging the gas line.

: DO NOT wet electronic components during the leak test. Wetting electronic components may damage circuitry and cause a hazardous situation. Dry moisture from all leads and terminals if wetting

19

Image 21
Contents GAS Fired High Efficiency Furnace Table of Contents Section Safety Information Page Page Page Page Page Model II. Furnace SpecificationsCMC1-50D36 CMC1-75D36 CMC1-50DV3 CMC1-75DV3 Description QTY Installation Parts PackagesPage Combustible Material NON-COMBUSTIBLE MaterialModels CMA3/CMC1 IV. General Installation Furnace Location Coil Cabinet Model CE113S / CE213T Page Cottage Base Model 01COT Base for CMA3 models only Closet Installation Alcove InstallationCMA3 Series CMC1 Series Fuel Piping General Venting Requirements Maximum Vent Length Connecting the Exhaust Vent and Combustion AIR Intake Page Page Page Page Vent Terminal Location Guidelines Connecting the Furnace to Roof Vent / AIR Terminations Page Condensate Drain Line and Trap Assembly Electrical Branch Supply Circuit Electrical WiringAWG Blower Delay Settings Blower Motor Speed WiringCMA3-50D36 CMA3-75D36 CMC1-50D36 CMC1-75D36 CMC1-50DV3 CMC1-75DV3 Field Wiring and Replacing Wiring Starting the Unit Sequence of Operations END Cycle Operating Instructions Initial Start UPAdjustment of BTU Input Rate Burner Adjustment GAS Pressure Chart for CMA*/CMC* Model FurnacesSetting Temperature Rise Furnace Checkout Procedure VII. Dealer Maintenance VI. Installers Instructions to UserInducer Blower Assembly Condensate LINE/TRAP AssemblyElectrical General Inspection Vent Pipe Combustion AIR IntakeGASKETS/SEALING Materials Cleaning the Coil AIR SideHeat Exchanger House AIR BlowerFilter Maintenance Procedure Filter ReplacementDiagnostic Features LED will also flash once at power-up Setting Above AT the Integrated CONTROL? After GAS Valve OPENS, do Burners IGNITE? Is LED Light If LED Light Flashes FLASH, then Pause System Lockout Appendix a Replacement Parts Page Page Page Appendix B Wiring Diagrams

CMC1-75DV3N, CMA3-75D36N, CMA3-50D36N, CMC1-75D36N, CMC1-50D36N specifications

Thermo Products offers a versatile range of heating solutions that cater to various industrial and commercial applications. Among their popular models are the CMC1-75DV3N, CMC1-50DV3N, CMA3-50D36N, CMC1-50D36N, and CMC1-75D36N. Each model is engineered to deliver efficient performance and durability, making them ideal for meeting diverse heating needs.

The CMC1-75DV3N is tailored for high-capacity heating requirements, featuring advanced heating technology that ensures rapid and consistent heating. Its robust design includes high-efficiency burners, and the unit is built with durable materials for extended lifespan. This model is equipped with integrated safety mechanisms that prevent overheating and ensure reliable operation.

In contrast, the CMC1-50DV3N is designed for medium-sized applications, prioritizing both efficiency and cost-effectiveness. It includes automated controls to optimize energy usage while maintaining consistent temperature outputs. Its compact footprint makes it suitable for installations with space constraints, without compromising on heating performance.

The CMA3-50D36N model introduces enhanced energy management features, offering dynamic heating solutions. This model leverages advanced thermal technologies that aim to reduce energy consumption while maximizing heating output. Its versatile installation options allow users to adapt the unit to their specific space requirements seamlessly.

The CMC1-50D36N and CMC1-75D36N models are recognized for their adaptability across various applications. The CMC1-50D36N specifically caters to smaller heating needs, while the CMC1-75D36N serves larger spaces. Both units come equipped with user-friendly interfaces that simplify operation and adjustments, allowing for precise temperature control.

All models feature high-quality insulation and construction, helping to minimize heat loss and enhance system efficiency. They are designed with maintenance in mind, ensuring easier access to key components for service and repairs.

Through the incorporation of customizable settings, these models can suit the unique requirements of different environments, whether it be industrial facilities, commercial spaces, or residential buildings. With Thermo Products' commitment to innovation and quality, these heating solutions exemplify reliability, making them a solid choice for anyone in need of efficient heating technology.