Thermo Products CMC1-75DV3N, CMC1-50DV3N, CMC1-50D36N Vent Terminal Location Guidelines

Page 29

All installations and services must be performed by qualified service personnel.

4. Vent Terminal Location Guidelines

: Bushes, shrubs, or any vegetation that may restrict the flow of flue products must be kept away from vent and air intake terminations. Terminations must also be kept clear of any leaves, weeds, combustible materials, snow, and ice build-up. Avoid locating the vent terminal over areas where dripping of condensate, or small pools of acidic condensate, could create a problem.

In addition to following any local code requirements, when possible, utilize the guidelines below in locating the vent terminal to help insure trouble-free operation of a sidewall vented furnace:

Avoid locating the vent terminal on a wall facing prevailing winds and wide- open areas. When impractical, choose a location that protects the vent from strong winds, such as behind a fence or hedge.

In geographical areas with considerable snowfall, it is advisable to locate the vent terminal much higher than the minimum 12-inches above ground to prevent blockage by snow accumulation or drifting.

The vent and combustion air terminations shall be checked periodically, at least at the start of each heating season, for restriction or blockage from foreign material in the exhaust vent or in the air intake piping. Clean the air intake and vent terminations when necessary.

I.Installation Of Outside Exhaust / Intake Terminations

1.After determining appropriate installation locations (suitable locations must observe all clearances specified in this manual), mark and cut two (2), 2-3/8 inch diameter holes in the outside wall for the outdoor terminal(s)

2.Measure and cut two (2), 2-inch diameter thermoplastic pipes 1-1/2 inches longer than the depth of the wall. (Cutting the pipe longer leaves a ¾ inch connection allowance at both ends of the pipe.) Using PVC pipe cement, glue a PVC elbow or coupling fitting to one (1) end of each pipe.

Before inserting the pipe through the wall, mark the other end of the pipe so the elbow orientation can be determined. Also, if a protective shield (refer to Section H., passage 1. of this manual) will be used on the exterior surface of the wall, it should be installed at this time. From the inside, glue a coupling fitting to each pipe, using PVC pipe cement, while being careful to maintain the proper orientation of the termination elbow(s). Complete the assembly of the outlet and inlet as shown in Figure 10, making sure that the spacing between the inlet and outlet complies with that noted in Figure 8.

27

Image 29
Contents GAS Fired High Efficiency Furnace Table of Contents Section Safety Information Page Page Page Page Page Model II. Furnace SpecificationsCMC1-50D36 CMC1-75D36 CMC1-50DV3 CMC1-75DV3 Description QTY Installation Parts PackagesPage Models CMA3/CMC1 Combustible MaterialNON-COMBUSTIBLE Material IV. General Installation Furnace Location Coil Cabinet Model CE113S / CE213T Page Cottage Base Model 01COT Base for CMA3 models only Closet Installation Alcove InstallationCMA3 Series CMC1 Series Fuel Piping General Venting Requirements Maximum Vent Length Connecting the Exhaust Vent and Combustion AIR Intake Page Page Page Page Vent Terminal Location Guidelines Connecting the Furnace to Roof Vent / AIR Terminations Page Condensate Drain Line and Trap Assembly Electrical Branch Supply Circuit Electrical WiringAWG Blower Delay Settings Blower Motor Speed WiringCMA3-50D36 CMA3-75D36 CMC1-50D36 CMC1-75D36 CMC1-50DV3 CMC1-75DV3 Field Wiring and Replacing Wiring Starting the Unit Sequence of Operations END Cycle Operating Instructions Initial Start UPAdjustment of BTU Input Rate Burner Adjustment GAS Pressure Chart for CMA*/CMC* Model FurnacesSetting Temperature Rise Furnace Checkout Procedure VII. Dealer Maintenance VI. Installers Instructions to UserInducer Blower Assembly Condensate LINE/TRAP AssemblyElectrical General Inspection Vent Pipe Combustion AIR IntakeGASKETS/SEALING Materials Cleaning the Coil AIR SideHeat Exchanger House AIR BlowerDiagnostic Features Filter Maintenance ProcedureFilter Replacement LED will also flash once at power-up Setting Above AT the Integrated CONTROL? After GAS Valve OPENS, do Burners IGNITE? Is LED Light If LED Light Flashes FLASH, then Pause System Lockout Appendix a Replacement Parts Page Page Page Appendix B Wiring Diagrams

CMC1-75DV3N, CMA3-75D36N, CMA3-50D36N, CMC1-75D36N, CMC1-50D36N specifications

Thermo Products offers a versatile range of heating solutions that cater to various industrial and commercial applications. Among their popular models are the CMC1-75DV3N, CMC1-50DV3N, CMA3-50D36N, CMC1-50D36N, and CMC1-75D36N. Each model is engineered to deliver efficient performance and durability, making them ideal for meeting diverse heating needs.

The CMC1-75DV3N is tailored for high-capacity heating requirements, featuring advanced heating technology that ensures rapid and consistent heating. Its robust design includes high-efficiency burners, and the unit is built with durable materials for extended lifespan. This model is equipped with integrated safety mechanisms that prevent overheating and ensure reliable operation.

In contrast, the CMC1-50DV3N is designed for medium-sized applications, prioritizing both efficiency and cost-effectiveness. It includes automated controls to optimize energy usage while maintaining consistent temperature outputs. Its compact footprint makes it suitable for installations with space constraints, without compromising on heating performance.

The CMA3-50D36N model introduces enhanced energy management features, offering dynamic heating solutions. This model leverages advanced thermal technologies that aim to reduce energy consumption while maximizing heating output. Its versatile installation options allow users to adapt the unit to their specific space requirements seamlessly.

The CMC1-50D36N and CMC1-75D36N models are recognized for their adaptability across various applications. The CMC1-50D36N specifically caters to smaller heating needs, while the CMC1-75D36N serves larger spaces. Both units come equipped with user-friendly interfaces that simplify operation and adjustments, allowing for precise temperature control.

All models feature high-quality insulation and construction, helping to minimize heat loss and enhance system efficiency. They are designed with maintenance in mind, ensuring easier access to key components for service and repairs.

Through the incorporation of customizable settings, these models can suit the unique requirements of different environments, whether it be industrial facilities, commercial spaces, or residential buildings. With Thermo Products' commitment to innovation and quality, these heating solutions exemplify reliability, making them a solid choice for anyone in need of efficient heating technology.