Thermo Products CDX1-100N, CDX1-75N, CHX1-125N, CHX1-75N, CHX1-100N Filters CHX1 Models Highboys

Page 29

All installations and services must be performed by qualified service personnel.

Figure 18

2.A drip leg must be used on both LP and natural gas installations prior to the furnace in order to trap oil, condensate and other impurities which might otherwise lodge in the gas valve or plug the burner orifice. A drip leg shall be provided at the outlet of the gas meter when there is excessive condensation between the gas meter and the furnace. Failure to install a drip leg may void the limited warranty on the furnace.

: All gas piping must be leak tested using a soap and water solution (when the gas is turned on) following the procedure outlined in Section III, J, of this manual. A final test for gas leakage must be made after purging the gas line (refer to Section IV, B, of this manual). This test must be conducted with the unit operating and should include the furnace piping and gas valve. Never use an open flame to check for a gas leak.

: Care must be taken not to wet electronic components during leak test. Wetting the primary ignition module may damage its circuitry and cause a hazardous situation. Dry moisture from all leads and terminals if wetting occurs. Wait at least 24 hours for the circuit to fully dry before energizing the burner circuit.

K. FILTERS

1. CHX1 MODELS: HIGHBOYS

It is necessary to cut the return air opening in the bottom or side casing depending upon the needs of the specific installation.

NOTICE: If your CHX1 will require air delivery above 1800 CFM, it is advisable that both sides, a combination of 1 side and the bottom, or the bottom only be used for return air. (If a return is cut in the bottom, it should be as large as the return opening in the equivalent CDX1 model. (See specification sheet in beginning of this manual).

23

Image 29
Contents MG-1010 TWO Stage Condensing GAS FurnaceSafety Information Page Iii Page Index Section Beginning Temperature Rise Blower Motor HP Power Chokes II. Furnace Specifications CHX1 Series Model noHeight of Casing Width of Casing Depth of CasingCDX1-75 CDX1-100 CDX1-125 BTU/HR Input High fire / Low fire CDX1 Series Model noBTU/HR Output High fire / Low fire @HEATING TAP C High fire / Low fire#S00S4379 Installation Parts Packages CHX1-75 Description Quantity#S00S4378 #S00S4380 Installation Parts Packages CDX1-75 Description Quantity#S00S4381 CHX1-75 CHX1-100 CHX1-125 CDX1-75 CDX1-100 CDX1-125 III. General InstallationCodes and Clearances B1. CDX1 Horizontal Application Furnace LocationPage Maximum Vent Length Replacing AN Existing Furnace from a Common VentGeneral Requirements for Venting CHX1/CDX1 Sidewall Venting Vent Terminal Location Requirements E1. Single Pipe Sidewall Venting Option Vent Terminal Location GuidelinesOptional Terminations Installation of Outside VENT/AIR Intake TerminationsPage Page Connecting the Exhaust Vent to the Inducer Page Connecting the Combustion AIR Inlet Connecting the Furnace to Roof VENT/AIR Terminations Trap Assembly Mounted on CDX1 Trap Assembly Mounted on CHX1Page General GAS Piping Filters CHX1 Models Highboys CDX1 Models Counterflows USE of NON-THERMO Pride Filter Retention Means WiringRate AIR Velocity Furnace ModelThermostat Connections and Anticipator Setting Electronic AIR Cleaner EAC and Humidifier InstallationBlower and Control Panel Wiring Field Wiring and Replacing Wiring Settings Low fire High fire CDX1-75CFM CHX1-75Contacts Close Retry will be Made If System is in Lockout Operating Instructions Initial Start UPGas flowrate by clocking gas meter Exploded View of CDX/CHX Gas Control System BTU CHX Low CDX Low Model Series CHX Low CDX LowNormal Manifold Pressure in. W.GChecking The Burner Flame Sketch of Typical Main Burner Flames During Operation Checkout ProcedureConverting GAS Flow Rate Installers Instructions to User Furnace Checkout ProcedureVI. Troubleshooting Diagnostic Features Terminals IND HI to IND N or IND LO to Is the High Limit Page 50V61-143 Control AIR Blower Turn OFF Replacement parts list for CHX1-75, CHX1-100 and CHX1-125 Page Replacement parts list for CDX1-75, CDX1-100 and CDX1-125 Page Appendix B Wiring Diagrams
Related manuals
Manual 59 pages 47.89 Kb

CDX1-100N, CDX1-125N, CHX1-100N, CHX1-75N, CHX1-125N specifications

Thermo Products has established itself as a leader in the HVAC industry, providing innovative solutions for climate control with their latest product line, including the CHX1-125N, CDX1-75N, CDX1-100N, CHX1-75N, and CHX1-100N models. These units are designed for both efficiency and performance, catering to a wide range of heating and cooling needs.

One of the standout features of these models is their high energy efficiency ratings. Utilizing advanced inverter technology, these units dynamically adjust their operating frequency, optimizing energy consumption while maintaining consistent temperature control. This adaptability not only enhances comfort but also significantly lowers energy bills, making them an eco-friendly choice for both residential and commercial applications.

The CHX1 series, including the CHX1-125N, CHX1-75N, and CHX1-100N, is renowned for its robust build quality and superior performance in extreme conditions. They can operate effectively in varied environments, ensuring reliable heating during harsh winters and efficient cooling amid hot summers.

In contrast, the CDX1 series—featuring the CDX1-75N and CDX1-100N—focuses on delivering exceptional versatility. These models come equipped with advanced multi-zone capabilities, allowing users to control different areas or rooms with precision. This zoning capability not only enhances comfort but also optimizes energy efficiency by allowing users to heat or cool only the spaces that are occupied.

A common characteristic among all these models is their quiet operation. Designed with noise-reduction technologies, the units are engineered to operate with minimal sound, making them ideal for residential settings, offices, and other noise-sensitive environments.

Moreover, Thermo Products emphasizes user-friendly interfaces in their design. With intuitive controls and smart connectivity options, users can easily manage their HVAC systems through mobile applications, ensuring convenience and optimal temperature management from anywhere.

Overall, Thermo Products’ CHX1-125N, CDX1-75N, CDX1-100N, CHX1-75N, and CHX1-100N models exemplify the perfect blend of innovation, efficiency, and user-centered design. These heating and cooling solutions not only meet the demands of modern living but also contribute to sustainability efforts, making them a valuable addition to any climate control system.