omconfig Battery Commands

The following sections provide the omconfig command syntax required to execute battery tasks.

Table 8-24. omconfig Battery Commands

Required Command Levels (1, 2, 3) Optional name=value pairs

omconfig storage battery

action=recondition controller=id battery=id action=startlearn controller=id battery=id action=delaylearn controller=id battery=id days=d hours=h

omconfig Recondition Battery

Use the following omconfig command to recondition a controller battery. For more information on batteries and the recondition process, see the online help.

Complete Syntax

omconfig storage battery action=recondition controller=id battery=id

where id is the controller ID and battery ID as reported by the omreport command. To obtain this value, enter omreport storage controller to display the controller IDs and then enter omreport storage battery controller=ID to display the ID for the controller battery.

Example Syntax

For example, to recondition the battery on controller 1, enter:

omconfig storage battery action=recondition controller=1 battery=0

omconfig Start Battery Learn Cycle

Use the following omconfig command to start the battery learn cycle.

Complete Syntax

omconfig storage battery action=startlearn controller=id battery=id

where id is the controller ID and battery ID as reported by the omreport command. To obtain this value, enter omreport storage controller to display the controller IDs and then enter omreport storage battery controller=ID to display the ID for the controller battery.

Example Syntax

For example, to start the learn cycle on controller 1, enter:

omconfig storage battery action=startlearn controller=1 battery=0