Table 4-11. omconfig chassis memorymode

name=value pair 1

Description

 

 

index=<n>

Number of the chassis where the memory module resides (the default is chassis 0, the

 

main system chassis).

redundancy=spare Spare disables the memory module that has a correctable memory event and copies the mirror disabled raid5 failing module’s data to a spare bank.

Disabled indicates that the system is not to use other available memory modules if uncorrectable memory events are detected.

Mirror switches the systems to a mirrored copy of the memory if the failing module has an uncorrectable memory event. In mirror mode, the operating system does not switch back to the original module until the system reboots.

RAID5 is a method of system memory configuration. This is logically similar to the RAID 5 mode used in hard drive storage systems. This memory mode gives you an extra level of memory checking and error recovery at the expense of some memory capacity. The RAID mode supported is RAID level 5 striping with rotational parity.

omconfig chassis remoteaccess

NOTE: This command is applicable to PowerEdge x8xx and x9xx systems only.

Use the omconfig chassis remoteaccess command to configure:

Remote access on a local area network (LAN).

The serial port for BMC or RAC, whichever is installed.

The BMC or RAC on a serial over LAN connection.

Terminal settings for the serial port.

Advanced settings for a serial over LAN connection.

Information on a BMC or RAC user.

NOTE: You have to enter the user ID to configure user information.

Type:

omconfig chassis remoteaccess

omconfig: Managing Components Using the Instrumentation Service

75

Page 75
Image 75
Dell Command Line Interface manual Omconfig chassis remoteaccess, Main system chassis