90 omconfig: Managing Components Using the Instrumentation Service

Available Alert Actions

Table4-20 shows the alert actions for each component that allows you to configure an alert action
.

Components and Events for Which You Can Set Alert Actions

Table4-21 lists the components and the events for which you can set alert actions. Components are listed in alphabetical order, except that warning events always precede failure events for a component.
Table 4-20. Alert Actions You Can Set for Warning and Failure Events
Alert Action Setting Description
alert=true | false true: Enables your system's console alert. When enabled, the monitor
attached to the system from which you are running Server Administrator
displays a visual alert message.
false: Disables your system's console alert.
broadcast=true | false true: Enables a message or alert to be broadcast to all users who have an
active Terminal (or Remote Desktop) session (Windows) or to operators
that have an active shell on the local system (Linux).
false: Disables alert broadcasts.
clearall=true Clears all actions for this event.
execappath=<string> Sets the fully qualified path and filename of the application you want to
execute in case of an event for the component described in this window.
execapp=false Disables the executable application.
Table 4-21. Events for Which You Can Set Alert Actions
Event Name Description
event=batterywarn Sets actions when a battery probe detects a warning value.
event=batteryfail Sets actions when a battery probe detects a failure value.
event=currentwarn Sets actions when a current probe detects a warning value.
event=currentfail Sets actions when a current probe detects a failure value.
event=fanwarn Sets actions when a fan probe detects a warning value.
event=fanfail Sets actions when a fan probe detects a failure value.
event=hardwarelogwarn Sets actions when a hardware log detects a warning value.
event=hardwarelogfull Sets actions when a hardware log is full.
event=intrusion Sets actions when a chassis intrusion event is detected.
event=memprefail Sets actions when a memory probe detects a prefailure value.
event=memfail Sets actions when a memory probe detects a failure value.
event=powersupply Sets actions when a power supply probe detects a failure value.