omconfig system platformevents

Use the omconfig system platformevents command to configure shutdown action, if any, to be taken for a specific platform event. You can also enable or disable platform event filter alert generation.

NOTICE: If you set a platform event shutdown action to anything other than "none", your system will forcefully shutdown when the specified event occurs. This shutdown is initiated by firmware and is carried out without first shutting down the operating system or any of the applications running on your system.

Table 4-23 shows the valid parameters for the command.

NOTE: Alert settings are mutually exclusive and can be set one at a time only. The action settings are also mutually exclusive and can be set one at a time only. However, alert and action settings are not mutually exclusive of each other.

Table 4-23. Shutdown Action

Shutdown Action

Description

 

 

alert=disable

Disables the SNMP alert.

alert=enable

Enables the SNMP alert to be sent.

action=none

Takes no action when the system is hung or has crashed.

action=powercycle

Turns the electrical power to the system off, pauses, turns the power on, and

 

reboots the system.

action=poweroff

Turns off the electrical power to the system.

action=reboot

Forces the operating system to shut down and initiates system startup,

 

performs BIOS checks, and reloads the operating system.

 

 

Table 4-24 lists the components and the events for which you can set platform events. Components are listed in alphabetical order, except that warning events always precede failure events for a component.

Table 4-24. omconfig system platformevents

Event Name

Description

 

 

alertsenable=true false

true: Enables generation of platform event filter alerts.

 

false: Disables generation of platform event filter alerts.

 

NOTE: This setting is independent of the individual platform event filter alert settings.

 

For a platform event filter to generate an alert, both the individual alert and the global

 

event alert must be enabled.

event=batterywarn

Sets action or enables/disables alert generation when a battery device detects that

 

the battery is pending a failure condition.

event=batteryfail

Sets action or enables/disables alert generation when a battery device detects that

 

the battery has failed.

event=discretevolt

Sets action or enables/disables alert generation when a discrete voltage probe

 

detects that the voltage is too low for proper operation.

omconfig: Managing Components Using the Instrumentation Service

93

Page 93
Image 93
Dell Command Line Interface manual Omconfig system platformevents