To view the contents of the alert log, type:

omreport system alertlog

To view the contents of the command log, type:

omreport system cmdlog

To view the contents of the ESM log, type:

omreport system esmlog

ESM Log Overall Health Status

When you type omreport system esmlog, the Embedded Systems Management (ESM) report displays. The first line of the report reflects the overall health of the system hardware. For example, Health: OK means that less than 80 percent of the space allotted for the esmlog is occupied with messages. If 80 percent or more of the allotted space for the esmlog is occupied, the following caution appears:

Health: Non-Critical

If a caution appears, resolve all warning and critical severity conditions, and then clear the log.

omreport system alertaction

Use the omreport system alertaction command to see a summary of alert actions that have been configured for warning and failure events on your system components. Alert actions determine how Server Administrator responds when a component has a warning or failure event.

The omreport system alertaction command is useful for viewing which alert actions have been specified for components. To set an alert action for a component, you must use the omconfig system alertaction command. See "omconfig: Managing Components Using the Instrumentation Service."

Components and Events for Which You Can View Alert Actions

You can view alert action properties for the following components and events, if the components/events are present on the system:

battery warning

battery failure

chassis intrusion

current probe warning

current probe failure

fan warning

fan failure

memory pre-failure

memory failure