omreport chassis leds

Use the omreport chassis leds command to find out whether clear hard drive fault is supported and what severity level lights up the LED. Type:

omreport chassis leds index=n

The index parameter is optional. If you do not specify the index, Server Administrator displays a summary of LED information for chassis 0. If you specify the index, Server Administrator displays a summary for a specific chassis.

The following is an example output:

Flash

chassis indentify

LED state :

Off

Flash

chassis

indentify

LED

:

300

timeout value

 

 

 

 

omreport chassis memory

Use omreport chassis memory to see details for each memory module slot in your system. If your system supports redundant memory, this command also displays the status, state, and type of memory redundancy implemented on your system. Type:

omreport chassis memory index=n

The index parameter is optional. If you do not specify the index, Server Administrator displays information for all memory on your system. If you specify the index, Server Administrator displays a summary for a specific memory module.

Output for an occupied memory slot may resemble the following:

Index

: 1

Status

: OK

Connector Name

: DIMM_B

Type

: SDRAM-SYNCHRONOUS

Size

: 256 MB

An unoccupied memory slot still has a connector name. Output for an unoccupied memory slot may resemble the following:

Index

: 2

Status

: Unknown

Connector Name

: DIMM_D

Type

: Not Occupied

Size

: Unknown

omreport: Viewing System Status Using the Instrumentation Service

33

Page 33
Image 33
Dell Command Line Interface manual Omreport chassis leds, Omreport chassis memory