omconfig rac remote

Use the omconfig rac remote command to specify the remote features property values. Table 7-9 shows the valid parameters for the command.

Table 7-9. omconfig rac remote

name=value pair

Description

 

 

floppytftpenable=true false

true: Enables remote boot.

 

false: Disables remote boot.

floppytftpipaddr=<text>

Sets the floppy TFTP address.

floppytftppath=<text>

Sets the floppy TFTP path.

fwupdatetftpipaddr=<text>

Sets the firmware TFTP address.

fwupdatetftppath=<text>

Sets the directory path on the TFTP server where the

 

firmware update images reside.

 

 

Example Command

The following example sets one name=value pair.

Type:

omconfig rac remote floppytftpenable=true

The following message appears:

Command Successful. Please reset RAC card!

omconfig rac rmdialinuser

Use the omconfig rac rmdialinuser command to remove a dial-in user. Table 7-10 shows the valid parameters for the command.

Table 7-10. omconfig rac rmdialinuser

name=value pair

Description

 

 

username=<text>

Specifies the user name of entry which is to be deleted. If no

 

user name is specified, an index must be specified.

index=<n>

Specifies the index of the entry which is to be deleted. If no

 

index is specified, a user name must be specified.

 

 

omconfig rac: Managing the Remote Access Controller

129

Page 129
Image 129
Dell Command Line Interface manual Omconfig rac remote, Omconfig rac rmdialinuser, 129