omconfig: Managing Components Using the Instrumentation Service 53
platformevents A Determines the shutdown action, if any, to be
taken for a specific platform event. Also,
enables and disables platform events filter
alertgeneration.
recovery P, A Determines in advance how your system
responds to a hung operating system.
shutdown A Allows the administrator to select from several
options when shutting down the system.
thrmshutdown A Sets the severity level at which a thermal event
triggers a system shutdown.
webserver A Starts or stops the Web server.
chassis
biossetup A Configures behavior of specific system
components that are controlled by the BIOS.
bmc A Configures remote access information.
NOTE: This subcommand will be phased-out in
future releases and replaced by the
subcommand remoteaccess.
currents P, A Configures current probe warning thresholds
by default or by value.
fans P, A Configures fan probe warning thresholds by
default or by value.
NOTE: You cannot change threshold values on
embedded server management (ESM3) and
Dellâ„¢ PowerEdgeâ„¢ x8xx systems.
fancontrol P, A Allows you to optimize fan speed for
maximum cooling or quiet operation.
frontpanel A Configures the Power button and Nonmasking
Interrupt (NMI) button if present on
thesystem.
info P, A Allows you to set an initial value for, or to edit
the value for, asset tag or chassis name.
leds P, A Specifies when to flash a chassis fault LED or
chassis identification LED, and allows you to
clear the LED for the system's hard drive.
Table 4-1. omconfig Command Level 1, Level 2, and Level 3 (continued)
Command
level 1
Command
level 2
Command
level 3
User privilege
required
Use