Table 3-1 is a high-level summary of the omreport command. The column titled "Command level 1" shows the omreport command at its most general. "Command level 2" shows the major objects or components that you can view using omreport (about, chassis, storage, system, and rac). "Command level 3" lists the specific objects and components for which you can view reports. "User privilege required" refers to the type of privilege you need to perform the command, where U=User, P=Power User, and A=Administrator. "Use" is a very general statement about the actions that can be performed using omreport. More details about syntax and use of the command appear later in this section.

Table 3-1 shows the omreport commands available for about, system, and main system chassis. For information about viewing storage components, see "omreport: Viewing System Status Using the Instrumentation Service."

Table 3-1. omreport Command Level 1, Level 2, and Level 3

Command

Command

Command

User

Use

level 1

level 2

level 3

privilege

 

 

 

 

required

 

 

 

 

 

 

omreport

 

 

 

 

 

about

 

U, P, A

Shows version number and properties for the

 

 

 

 

Server Administrator program.

 

 

details=true

U, P, A

Displays information for all of the Server

 

 

 

 

Administrator programs that are installed.

 

chassis

 

U, P, A

Shows a general status for all main components.

 

 

acswitch

U, P, A

Shows failover settings where redundant AC

 

 

 

 

power lines are supported in a system.

 

 

batteries

U, P, A

Shows properties set for batteries.

 

 

bios

U, P, A

Shows BIOS facts such as manufacturer, version,

 

 

 

 

and date last updated.

 

 

biossetup

A

Shows BIOS setup properties configured during

 

 

 

 

system boot.

 

 

bmc

U, P, A

Shows general information on remoteaccess.

 

 

 

 

NOTE: This subcommand will be phased-out in

 

 

 

 

future releases. It will be replaced by the

 

 

 

 

subcommand remoteaccess.

 

 

currents

U, P, A

Shows the status and thresholds for the system

 

 

 

 

current sensors.

 

 

fancontrol

U, P, A

Shows properties set for fan speed.

 

 

fans

U, P, A

Shows status and thresholds for system fans.

 

 

firmware

U, P, A

Shows firmware properties such as version, date

 

 

 

 

of last update, and whether the firmware

 

 

 

 

is updatable.

22

omreport: Viewing System Status Using the Instrumentation Service

Page 22
Image 22
Dell Command Line Interface Omreport Command Level 1, Level 2, and Level, Server Administrator program, Date last updated