60 omconfig: Managing Components Using the Instrumentation Service
attribute=secondaryscsi setting=on | off on: Enables this device.
off: Disables this device.
attribute=serialcom setting=off | on |com1 |com2 off: Disables serial communication setting.
on: Enables serial communication setting without
console redirection.
com1: Enables serial communication setting with
console redirection via COM 1.
com2: Enables serial communication setting with
console redirection via COM 2.
attribute=serialport1 setting=off | auto | com1 | com3
| bmcserial | bmcnic | rac |
com1bmc
off: Disables serial port 1.
auto: Maps serial port 1 to a COM port.
com1: Maps serial port 1 to COM port1.
com3: Maps serial port 1 to COM port3.
bmcserial: Maps serial port 1 to BMCSerial.
bmcnic: Maps serial port 1 to the Baseboard
Management Controller (BMC) Network
Interface Controller(NIC).
rac: Maps serial port 1 to the Remote Access
Controller (RAC).
com1bmc: Maps serial port 1 to COM port 1 bmc.
NOTE: This command is valid on PowerEdge 1850,
2800, and 2850systems only.
attribute=serialport2 setting=off | auto | com2 | com4 off: Disables serial port 2.
auto: Maps serial port 2 to a COM port.
com2: Maps serial port 2 to COM port2.
com4: Maps serial port 2 to COM port4.
attribute=speaker setting=on | off on: Enables the speaker.
off: Disables the speaker.
attribute=uausb setting=on | backonly | off on: Enables the user-accessible USBport(s)
backonly: Enables only the user accessible
USBport(s) at the back of the system.
off: Disables the user-accessible USBport(s).
Table 4-2. BIOS Setup (continued)
name=value pair 1
attribute=
name=value pair 2
setting=
Description