Table 4-3. omconfig chassis bmc (continued)

name=value pair 1

name=value pair 2

Description

config=

 

 

 

 

 

config=nic

nicselection=nic1 teamednic1nic2

nic1: Enables NIC 1.

(continued)

dracnic

teamednic1nic2: Enables NIC teaming

 

 

 

 

functionality.

 

 

dracnic: Enables DRAC NIC if DRAC 5 is

 

 

installed.

 

 

NOTE: The option nicselection is supported only

 

 

on PowerEdge x9xx systems.

 

 

NOTE: If there are multiple embedded NICs on

 

 

your system, you can select the NIC teaming

 

 

option to share the BMC management traffic

 

 

between them.

 

privilegelevel=administrator operator

administrator: Sets the maximum privilege

 

user

level that can be accepted on a LAN channel to

 

 

Administrator.

 

 

operator: Sets the maximum privilege level that

 

 

can be accepted on a LAN channel to Operator.

 

 

user: Sets the maximum privilege level that can

 

 

be accepted on a LAN channel to User.

 

subnet=Subnet

subnet: Sets a subnet mask if you have selected

 

 

static as the IP address source for the BMC

 

 

LAN interface.

 

vlanenable=true false

true: Enables the virtual LAN identification.

 

 

false: Disables the virtual LAN identification.

 

vlanid=number

number: Virtual LAN identification in the

 

 

range of 1 to 4094.

 

vlanpriority=number

number: Priority of virtual LAN identification

 

 

in the range of 0 to 7.

omconfig: Managing Components Using the Instrumentation Service

63

Page 63
Image 63