Default Minimum and Maximum Warning Thresholds

If you want to set both the upper and lower current warning threshold values to the recommended default value, type:

omconfig chassis currents index=0 warnthresh=default

You cannot default one value and set another. In other words, if you default the minimum warning threshold value, you are also selecting the default value for the maximum warning threshold value.

Specify a Value for Minimum and Maximum Warning Thresholds

If you prefer to specify values for the current probe warning thresholds, you must specify the number of the probe you are configuring and the minimum and/or maximum warning threshold values. In the following example, the probe that is being configured is probe 0:

omconfig chassis currents index=0 minwarnthresh=3.310 maxwarnthresh= 3.381

When you issue the command and the system sets the values you specify, the following message appears:

Current probe warning threshold(s) set successfully.

omconfig chassis fans

Use the omconfig chassis fans command to set fan probe warning thresholds. As with other components, you can view both warning and failure threshold values, but you cannot set failure thresholds.

Your system's manufacturer sets the minimum and maximum failure thresholds.

Valid Parameters for Fan Warning Thresholds

Table 4-6 shows the valid parameters for setting fan warning thresholds:

Table 4-6. omconfig chassis fans

name=value pair

Description

 

 

index=<n>

Number of the probe or probe index (must be specified).

warnthresh=default

Sets minimum and maximum warning thresholds to default.

minwarnthresh=<n>

Minimum warning threshold.

maxwarnthresh=<n>

Maximum warning threshold.

 

 

Default Minimum and Maximum Warning Thresholds

NOTE: Systems that contain ESM3, ESM4, and BMC capabilities do not allow you to set warning threshold values to default values.

If you want to set both the upper and lower fan warning threshold values to the recommended default value, type:

omconfig chassis fans index=0 warnthresh=default