The output from the omconfig chassis remoteaccess command lists each of the available configurations. Table 4-3 shows the valid parameters:

Table 4-12. omconfig chassis remoteaccess

name=value pair 1

name=value pair 2

Description

config=

 

 

 

 

 

config=advsol

characcuminterval=number

number: Sets the character accumulate

 

 

interval in 5 millisecond intervals.

 

charsendthreshold=number

number: Sets the number of characters. BMC

 

 

automatically sends a serial over LAN data

 

 

packet that contains this number of

 

 

characters as soon as this number of

 

 

characters (or greater) has been accepted

 

 

from the baseboard serial controller into

 

 

the BMC.

config=nic

enable=true false

true: Enables IPMI over LAN.

 

 

false: Disables IPMI over LAN.

encryptkey=text

confirmencryptkey=text

text: Text used for encryption and confirmation of encryption.

NOTE: The option text is supported only on PowerEdge x9xx systems.

gateway=Gateway

Gateway: Sets a gateway address if you have

 

selected static as the IP address source for the

 

BMC LAN interface.

enablenic=true false

true: Enables DRAC NIC.

 

false: Disables DRAC NIC

 

NOTE: The option enablenic is supported on

 

PowerEdge x9xx systems that have DRAC 5

 

installed.

IP address=IP

ip: Sets the IP address if you have selected

 

static as the IP address source for the BMC

 

LAN interface.

76

omconfig: Managing Components Using the Instrumentation Service

Page 76
Image 76