Table 3-3. omreport chassis bmc

name=value pair

Description

 

 

config=advsol

Reports advanced BMC information on a serial over local area network (LAN) connection.

config=nic

Reports BMC information for the LAN.

config=serial

Reports serial port information for BMC.

config=serialoverlan

Reports BMC information on a serial over LAN connection.

config=terminalmode

Reports terminal mode settings for the serial port.

config=user

Reports information on BMC users.

 

 

omreport chassis currents

Use the omreport chassis currents command to view current (amperage) probe status and settings. When you type:

omreport chassis currents index=n

the index parameter is optional. If you do not specify the index, Server Administrator displays a summary of status, readings, and thresholds set for all current probes present on your system. If you specify the index, Server Administrator displays a summary for a specific current probe.

omreport chassis fans

Use the omreport chassis fans command to view fan probe status and settings. When you type:

omreport chassis fans index=n

the index parameter is optional. If you do not specify the index, Server Administrator displays a summary of status, readings, and thresholds set for any fan probes that might be present on your system. If you specify the index, Server Administrator displays a summary for a specific fan probe.

omreport chassis fancontrol

Use the omreport chassis fancontrol command to see how fan speed is set on your system. Fan speed can be set to optimize speed for cooling or for quiet operation. Table 3-4 shows the available settings.

Table 3-4. Fan Control Settings

name=value pair

Description

 

 

speed=quiet

Set fan speed for quiet operation.

speed=maxcool

Set fan speed for maximum cooling.

 

 

30

omreport: Viewing System Status Using the Instrumentation Service

Page 30
Image 30
Dell Command Line Interface manual Omreport chassis currents, Omreport chassis fans, Omreport chassis fancontrol