Message:

BIOS setup configured successfully.

Command:

omconfig system assetinfo info=depreciation duration=6

Message:

Asset information set successfully.

Failure Messages

CLI failure messages provide reasons why some commands do not succeed. Some common reasons why commands fail include syntax errors and components that are not present. Many error messages provide syntax information that you can use to execute the command successfully.

If you try to execute a command for a component or feature that is not present in your system configuration, the error message states that the component is not present.

Command:

omreport chassis currents

Example message:

Error! No current probes found on this system.

Command:

omconfig chassis volts index=3 minwarnthresh=3.3000

Example message:

Error! Number with up to 3 digits after decimal point expected, read 3.3000

The value given by the command specifies more than 3 digits after the decimal point. A valid minimum warning threshold value for volts contains up to 3 digits after the decimal point.

Type:

omconfig chassis volts index=3 minwarnthresh=3.300

When you enter the revised command with three decimal points, you receive another error message:

Error! This voltage probe min warning threshold must be between 11.400 and 12.480.

Revised command:

omconfig chassis volts index=3 minwarnthresh=11.500

Message:

Voltage probe warning threshold(s) set successfully.

16