Table 4-12. omconfig chassis remoteaccess (continued)

name=value pair 1

name=value pair 2

Description

config=

 

 

 

 

 

config=nic

vlanenable=true false

true: Enables the virtual LAN identification.

(continued)

 

false: Disables the virtual LAN identification.

 

 

 

vlanid=number

number: Virtual LAN identification in the

 

 

range of 1 to 4094.

 

vlanpriority=number

number: Priority of virtual LAN identification

 

 

in the range of 0 to 7.

config=serial

baudrate=9600 19200 38400 57600

9600: Sets connection speed to 9600 bits

 

115200

per second.

 

 

19200:Sets connection speed to 19200 bits

 

 

per second.

 

 

38400: Sets the volatile and nonvolatile

 

 

connection speed to 38400 bits per second.

 

 

57600: Sets the volatile and nonvolatile

 

 

connection speed to 57600 bits per second.

 

 

115200: Sets the volatile and nonvolatile

 

 

connection speed to 115200 bits per second.

 

 

NOTE: Baud rates of 9600 and 19200 are

 

 

supported on PowerEdge 1800, 1850, 2800, and

 

 

2850 systems.

 

 

Baud rates of 9600, 19200, 38400, and 57600 are

 

 

supported on PowerEdge x9xx systems.

 

 

Baud rate of 115200 is supported on certain

 

 

systems that have a DRAC 5 installed.

 

flowcontrol=none rtscts

none: No control over the flow of

 

 

communication through the serial port.

 

 

rtscts: RTS is ready to send and CTS is clear

 

 

to send.

78

omconfig: Managing Components Using the Instrumentation Service

Page 78
Image 78
Dell Command Line Interface manual Sets connection speed to 9600 bits, Per second, To send