Table 8-16. omconfig Controller Commands (continued)

Required Command Levels (1, 2, 3) Optional name=value pairs

action=setcheckconsistency controller=id rate=<0 to 100>

action=exportlog controller=id action=importforeignconfig controller=id action=importrecoverforeignconfig controller=id action=clearforeignconfig controller=id

action=setpatrolreadmode controller=id mode=manual auto disable

action=startpatrolread controller=id action=stoppatrolread controller=id

omconfig Rescan Controller

Use the following omconfig command syntax to rescan a controller. See the online help for more information about using this command.

Complete Syntax

omconfig storage controller action=rescan controller=id

where id is the controller ID as reported by the omreport storage controller command.

Example Syntax

For example, to rescan controller 1, enter:

omconfig storage controller action=rescan controller=1

NOTE: The rescan controller is not supported on non–RAID SCSI and SAS controllers. You must reboot the system before Storage Management can see configuration changes on non-RAID SCSI controllers.

omconfig Global Rescan Controller

The omconfig storage controller action=globalrescan command was supported in previous releases of Storage Management. This command has been replaced by the omconfig storage globalinfo action= globalrescan command. When rescanning all controllers on the system and creating CLI scripts, it is preferable to use the omconfig storage globalinfo action=globalrescan command.

See the online help for more information about using this command.

Using the Storage Management Service