Roberts Gorden CGTH-30, CGTH-50, CGTH-40 service manual Cgth USE and Care Manual

Page 18

CGTH USE AND CARE MANUAL

 

Clearance to each

 

 

H

side of center line

3' (91 cm) within a height 15' (4.5 m) above

 

extended above

*

the meter/regulator assembly

 

meter/regulator

 

 

 

 

 

assembly

 

 

 

 

 

 

I

Clearance to

 

 

service regulator

3' (91 cm)

*

 

vent outlet

 

 

 

 

 

 

 

Clearance to non-

 

 

 

mechanical air

 

 

J

supply inletto

 

 

building or the

12" (30 cm)

9" (23 cm)

 

combustion air inlet

 

 

 

to any other

 

 

 

appliance

 

 

 

 

 

 

K

Clearance to

 

3' (91 cm) above if within 10' (3 m)

mechanical air sup-

6' (1.83 m)

horizontally

 

ply inlet

 

 

 

 

 

 

 

 

 

Clearance above

 

 

L

paved sidewalks or

 

 

paved driveway

7' (2.13 m)+

7’ (2.13 m)+

 

located on private

 

 

 

property

 

 

 

 

 

 

M

Clearance under

 

 

veranda, porch,

12' (30 cm)**

12" (30 cm)**

 

deck, or balcony

 

 

 

 

 

 

1In accordance with the current CSA B149.1, Natural Gas and Propane Installation Code

2In accordance with the current ANSI Z223.1/NFPA 54, National Fuel Gas Code

+A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single family dwellings and serves both dwellings.

** Permitted only if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the floor.

*For clearances not specified in ANSI Z223.1/NFPA 54 or CSA B149.1, one of the following shall be indicated:

a)A minimum clearance value determined by testing in accordance with section 4.7.3, 6.5.5, 8.5.5; or;

b)A reference to the following footnote:

"Clearance in accordance with local installation codes and the requirements of the gas supplier."

12

Image 18
Contents Caribe Page Roberts-Gordon, LLC Page Table of Figures Page Before YOU Begin Read This Manual Questions, Comments or SuggestionsRoberts-Gordon, LLC Heater Safety Unpacking the Heater 3.3.1 Manpower Requirements SafetyAbout the Heater Service Door Hanger Components Identification Components IdentificationWhere Can the Heater Be Installed? Where Cant the Heater Be Installed?Before Using the Heater Balanced Flue Construction Venting RequirementsVenting Codes Public GaragesHazardous Locations Heater LocationUsing the Heater Required Safe Distances from CombustiblesHorizontal Installation Required Safe Distances from Combustibles Inches Metric cmCanadian Installations US Installations Vent Terminal ClearancesCgth USE and Care Manual Reflector and Grille Dimension Model Minimum Maximum Rear Movable Hanger LimitsTo Turn Off Gas To Heater Sequence of Operation VentingHorizontal Venting With An Elbow Caring for the Heater Select models Suspension PointsProtective Grille included Bird ScreenCgth USE and Care Manual Warranty is Void if ROBERTS-GORDON will not PAY forLimitations on Authority Representatives Page Owner Warranty Registration Card
Related manuals
Manual 58 pages 49.39 Kb

CGTH-40, CGTH-50, CGTH-30 specifications

Roberts Gordon is a renowned manufacturer known for its innovative heating solutions, particularly in the realm of infrared heaters. Among their product lineup, the CGTH series, which includes the CGTH-50, CGTH-40, and CGTH-30 models, exemplifies high-performance technology tailored specifically for industrial and commercial applications.

The CGTH series is designed for versatility and efficiency, offering advanced features that enhance the heating experience in various environments. One of the standout features of these heaters is their infrared technology, which provides targeted warmth, making them ideal for large, open spaces such as warehouses, factories, and sporting facilities. Infrared heaters work by directly heating objects and people in their path rather than the air, ensuring quicker warmth and greater energy efficiency.

Each model offers different heating capacities, with the CGTH-50 boasting a maximum output of 50,000 BTUs, the CGTH-40 providing up to 40,000 BTUs, and the CGTH-30 generating 30,000 BTUs. This variety allows users to choose a model that best fits their heating needs based on the size and requirements of their space.

The units are designed for easy installation, featuring a modular design that allows for both indoor and outdoor applications. Moreover, the heaters can be integrated with various control systems, including programmable thermostats and remote management, enhancing user convenience and optimizing energy usage.

A critical aspect of the CGTH series is its emphasis on durability and safety. Each model is crafted using high-quality materials that can withstand harsh conditions typically found in industrial settings. Additionally, they incorporate safety features such as over-temperature protection and robust mounting brackets, ensuring peace of mind during operation.

Another important characteristic of the CGTH series is their efficiency. By minimizing energy waste and targeting heat output precisely, these heaters can significantly lower energy costs, making them not only environmentally friendly but also economically advantageous for businesses.

In summary, the Roberts Gordon CGTH-50, CGTH-40, and CGTH-30 infrared heaters stand out for their innovative technology, energy efficiency, and reliability. Whether for large commercial spaces or industrial environments, these heating solutions are designed to provide the comfort and performance required for any operation. With their robust features and customizable options, they remain a top choice for effective heating solutions in diverse settings.