For the latest list of supported hardware, see the HP website (http://www.hp.com/go/bladesystemupdates).

Firmware upgrade requirements

IMPORTANT: For compatibility and proper operation of HP Virtual Connect Manager, all system firmware must be current.

Always install the most current firmware for the following items:

Server blade system ROMs

Ethernet mezzanines

Fibre Channel mezzanines

HP BladeSystem Onboard Administrator

For additional information on required firmware versions and to download firmware upgrades, see the HP website (http://www.hp.com/go/bladesystemupdates).

Required firmware versions for this release

Product

Required firmware version

 

 

HP Onboard

Version 1.30 or later

Administrator

 

 

 

BL460c and BL480c

System ROM 2006.09.18 or later

 

 

BL465c and BL685c

System ROM 2006.12.02 or later

 

 

BL860c*

System, BMC, and iLO-2 version 1.01A

 

 

iLO

Version 1.20 or later

 

 

NC370i, NC373i, and

Boot code version 1.9.6 and C Class option ROM

NC373m

1.1.3** or later

 

 

NC326i, NC325m, and

Boot code version 3.28 and C Class option ROM

NC326m

1.1.3** or later

 

 

QLogic QMH2462 4Gb

For ProLiant server blades, use QLogic

FC HBA

multiboot image 1.57 (with BIOS 1.26) or

 

later

 

For Integrity server blades, use EFI 1.09 (in

 

multiboot 1.64) or later

 

 

HP Emulex LPe 1105-HP

Emulex boot-pair 6.00a2 and 3.2a1

4Gb FC

HBAnywhere or later

 

 

*This product is only supported by Virtual Connect v1.16

**Use the HP Gigabit Server Adapter Firmware Upgrade Utility for c-Class Blades version 1.10 (HP website

(http://h18023.www1.hp.com/support/files/server/us/download/25604.html)) or one of the online methods available for the OS. To find the online update method for your OS, go to the HP website (http://www.hp.com/go/bladesystemupdates) and search for Server Blade Software & Updates.

Versions 1.15, 1.15b, and 1.16 of HP Virtual Connect firmware check the server ROM image version and display an incompatible state only for server blades that have a VC Server Profile assigned and are using incompatible server ROM versions. No version checking of mezzanine card firmware is available, so be sure to verify that the mezzanine card firmware is up to date.

Hardware and firmware requirements 5

Image 5
Contents Part Number October 2007 First Edition Audience assumptions Contents Supported hardware Hardware and firmware requirementsHP Virtual Connect Manager firmware Required firmware versions for this release Firmware upgrade requirementsHP Virtual Connect Fibre Channel Module Compatibility Matrix New features Important notes and recommendations Important notes and recommendations General Known issuesFibre Channel and SAN boot User interface Firmware updateResolved issues Resolved issues