Roberts Gorden CTCU 15, CTCU 27, CTCU 11, CTCU 22, CTCU 7 Shelf Mounting and Hanging Suspension

Page 14

COMBAT® CTCU UNIT HEATER INSTALLATION OPERATION AND SERVICE MANUAL

Figure 3: Shelf Mounting and Hanging Suspension

Shelf Mounting

Hanging

 

 

 

 

 

 

 

 

 

 

 

 

Shelf

M10 Fasteners

Mounting

 

Brackets

 

(Fasten to

 

Wall Mounting

 

Bracket)

 

Wall Mounting

 

Bracket Arm

M8 Bolt

(Right & Left)

 

Washer

 

Lock Washer

 

M8 Locknut

Wall Mounting

Torque to 4.5 Nm (40 in lb)

 

Bracket Diagonal

 

Wall Mounting

 

Bracket Vertical

 

Description

Part Number

Qty.

Wall Shelf Mounting Bracket Kit

11111512K

1

Wall Suspension Mounting Bracket Kit

1111510K

1

Shelf Mounting Bracket Kit

11111511K

1

Description

Part Number

Qty.

Wall Suspension Mounting Bracket Kit

11111511K

1

Wall Mounting Bracket Arm Left

111WALL1L

1

Wall Mounting Bracket Arm Right

111WALL1R

1

Wall Mounting Bracket Vertical

111WAL2

2

Wall Mounting Bracket Diagonal

111WAL3

2

M8 x 85 mm Hex Head Bolt

97311405

6

M8

Lock Nut with Nylon Insert

92204504

6

M8

Flat Washer

95204502

6

M8

Lockwasher

96404502

6

Hardware provided to construct mounting bracket assembly only.

Figure 4: Vertical Louvres (Optional)

Remove Horizontal

 

 

 

 

Louvres

 

 

 

 

 

 

 

 

 

Install Vertical

 

 

 

 

 

Louvre Brackets

 

 

 

 

 

(top and bottom)

 

 

 

 

 

with supplied

 

 

 

 

 

screws.

 

Push in

 

 

Install Vertical

 

 

 

Louvres and Springs

 

Louvre and compress

 

 

into Brackets

 

spring to remove

 

 

with Springs at Top

 

(opposite end first)

 

 

 

 

Description

Part Number

Description

Part Number

Description

Part Number

Vertical Louvre Kit

11111901K

Vertical Louvre Kit

11111900K

Vertical Louvre Kit

11111902K

CTCU 7 and 11

CTCU 15 and 22

CTCU 27 and 32

 

 

 

Vertical Louvre Bracket

11111903

Vertical Louvre Bracket

11111903

Vertical Louvre Bracket

11111903

#10 Screw

S103

#10 Screw

S103

#10 Screw

S103

CTCU 7-11 Vertical Louvres

11111901

Instruction Sheet

91040021

27-32 Vertical Louvre

11111902

Louver Spring

90901200

 

 

Instruction Sheet

91040021

Instruction Sheet

91040021

 

 

 

 

For models 15 and 22, horizontal louvres are re-used.

8

Image 14
Contents Mbat Page Roberts-Gordon, LLC Page Table of Figures Page Product Approval Clearances to Combustibles Heater SafetyInstaller Responsibility Corrosive ChemicalsFlue Minimum Required Installation ClearancesCritical Considerations 3.1 Basic Information VentilationInstallation Clearances and Clearances to Combustibles Specifications 4.1 Ctcua All Models Dimension Data Ctcua All ModelsGeneral Technical Data Table All Models CTCU-7 CTCU-11 CTCU-15 CTCU-22Heater Installation 5.1 General Shelf Mounting and SuspensionShelf Mounting and Hanging Suspension Changing Flue and Air Intake Orientation Flue InstallationFlue Installation Type B22 ApplianceVertical and Horizontal Flue Termination Type B22 Appliance Heaters Installed Within the Heated Space Room Sealed InstallationOpen Flued Installation AIR SupplyGAS Piping ConnectionsBurner Controls Thermostat Wiring and Electrical InformationRemote Controls Remote Fan ControlsSite Wiring Ctcua Wiring Diagram Models 7Mechanical Checks CommissioningLouvres Begin Commissioning Before Operating the HeaterAutomatic Burner Control Box Sequence Check Gas Rate Combustion TestingPressure Switch Turning Off the HeaterCommon User Controls 11.3.1 Fan Thermostat Burner Lockout Reset ButtonHeater Operation Limit ThermostatTo Turn the Heater Off Simple Fault FindingSimple Fault Finding Burner Faults Heat Exchanger Maintenance Burner Maintenance12.3 Fan/Motor Assembly Maintenance Gas Control Valve MaintenanceGas Valves Conversion Between Gases 13.1 GeneralBurner Conversion Conduct Commissioning procedure as shown on Page 15, Section Troubleshooting For Automatic Ignition Burner Systems Turn on controlsTroubleshooting for Flame Supervision System StartTroubleshooting for Solenoid Valves Troubleshooting for Main FanGas Valve Removal and Replacement PartsBurner Components Burner Compartment Burner InjectorsIgnition Electrode and Flame Probe Flue Fan Vertical Installation 041 Fan and Limit Thermostats 15.8.1 Removal and Replacement Ctcua Axial Fan/Guard/Motor AssemblyFan Removal and Replacement To Replace the Fan AssemblyPage Page Some objects can catch fire or explode when placed
Related manuals
Manual 50 pages 34.89 Kb

CTCU 7, CTCU 22, CTCU 11, CTCU 15, CTCU specifications

Roberts Gorden offers a diverse range of high-performance make-up air units known as the CTCU series, which includes models CTCU 22, CTCU 15, CTCU 7, CTCU 27, and CTCU 11. Each model is designed to deliver efficient and reliable air management solutions for various industrial and commercial applications.

The CTCU 22 is renowned for its robust construction and powerful performance, providing exceptional air flow rates that can accommodate larger facilities. It features a high-efficiency heat exchanger and a multi-stage filtration system that ensures optimal indoor air quality while reducing energy consumption. This model is particularly beneficial for environments requiring high volumes of tempered air, making it ideal for manufacturing plants and warehouses.

CTCU 15, on the other hand, is slightly smaller yet offers remarkable versatility. With an integrated control system, it can easily adapt to changing operational demands, making it a preferred choice for businesses that experience variable occupancy levels. Its quiet operation minimizes workplace noise, and its energy-efficient design significantly cuts operational costs.

CTCU 7 is specifically engineered for smaller spaces without compromising performance. This unit features compact dimensions while still delivering adequate air flow for localized heating and ventilation needs. The advanced temperature control algorithms allow for precise adjustments, ensuring a comfortable environment even in tight areas.

CTCU 27 stands out with its advanced technology that includes integrated smart controls. This model offers real-time monitoring and data analytics to optimize performance and enhance energy efficiency. Its ability to connect with existing building management systems makes it an appealing choice for modern facilities aiming to improve sustainability initiatives.

The CTCU 11 is characterized by its user-friendly interface and maintenance accessibility. It is built with durable materials that extend its lifespan, ensuring long-term reliability. This unit is ideal for applications where regular maintenance is challenging, as its design allows for easy access to all critical components.

In summary, Roberts Gorden's CTCU series encompasses a range of units catered to various industrial needs. With features focusing on efficiency, flexibility, and user-friendliness, these models deliver high-quality air management solutions to improve indoor environments while reducing energy consumption.