20

U10 Family Product Manual, Rev. A

Note: Dimensions are shown in inches (mm).

1.00 ± 0.028

 

 

(25.4 ± 0.7)

 

 

 

 

0.230 ± 0.015

3X 6-32 UNC-2B

(5.84 ± 0.38)

 

max. insertion depth

 

0.14 (3.6) both sides

4.000 ± 0.010

 

(101.60 ± 0.25)

 

 

5.75 ± 0.03

 

(146.1 ± 0.8)

2.362 ± 0.010

 

 

(59.99 ± 0.25)

 

 

0.630 +0.030, –0.005

(16.00 +0.76, –0.13)

3X.250 ± .015

0.125 +0.030, –0.005

 

(3.18 +0.76, –0.13)

(6.35 ± 0.38)

 

 

 

(both sides)

 

 

Recommended

 

 

case temperature

 

 

measurement location

 

 

2.23 ± 0.03

0.180 ± 0.015

(56.6 ± 0.8)

3.72 ± 0.03

(4.57 ± 0.38)

(94.5 ± 0.8)

 

4X 6-32 UNC-2B max. insertion depth 0.22 (5.6)

1.750 ± 0.010

(44.45 ± 0.25)

2.375 +0.030, –0.005

(60.33 +0.76, –0.13)

3.750 ± 0.010 (95.25 ± 0.25)

4.00± 0.02 (101.6 ± 0.5)

Recommended case temperature measurement location

Figure 3. Mounting dimensions—top, side and end view

Image 28 Contents
Product Manual Page Product Manual Page Contents Configuring and mounting the drive ATA interfaceFigures U10 Family Product Manual, Rev. a Introduction Specification summary table Drive Specification ST320423A Contact start-stop cycles 25C 40% relative humidity Formatted capacity Default logical geometryPhysical organization Drive Specification ST320423A, ST315323A ST310212A Physical characteristicsRecording and interface technology Seek time Power specificationsStart/stop times Power consumption Power Mode Typical Watts Typical Amps RMS 12V Typical current profileConducted noise Power-management modesVoltage tolerance Environmental tolerances Ambient temperature Temperature gradientSleep mode Idle and Standby timers3.2 Wet bulb temperature Humidity 3.1 Relative HumidityAltitude ShockNonoperating vibration Operating vibrationDrive acoustics Agency certification Safety certification Electromagnetic susceptibilityReliability Electromagnetic compatibilityFCC verification Australian CE-Tick N176U10 Family Product Manual, Rev. a Configuring and mounting the drive Handling and static-discharge precautionsJumper settings Master/slave configuration Drive as master with a non-ATA-compatible slaveUltra ATA/66 cable Cable-select optionDrive mounting Mounting dimensions-top, side and end view ATA interface signals and connector pins ATA interfaceO pins and supported ATA signals Supported ATA commands Command name Command code in hex ATA-standard commandsIdentify Drive command Command nameATA-standard power-management commands ATA-standard security commandsWord Description 0C5AHWord Description Value Xx07HXx1FH Description if bit is set to Bit Word Set Features command 0CH4 S.M.A.R.T. commands Code in Features A.R.T. Command RegisterA.R.T. Command Register Page