COOLING PERFORMANCE DATA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTDOOR UNIT MODEL NO.

YZB03611

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INDOOR COIL MODEL NO.

FC/MC/PC/UC36

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CONDENSER

ID CFM

 

 

1000

 

 

 

 

1200

 

 

 

 

1400

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ENTERING AIR

ID DB (°F)

80

80

75

80

80

80

80

75

80

80

80

80

75

80

80

TEMPERATURE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ID WB (°F)

57

62

62

67

72

57

62

62

67

57

57

62

62

67

72

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T.C.

33.4

35.6

36.5

41.1

44.1

35.4

36.5

37.1

41.6

44.5

37.4

37.5

37.7

42.1

44.9

65

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

33.8

31.2

26.2

26.6

20.9

35.8

34.2

28.4

28.9

22.5

37.8

37.1

30.7

31.3

24.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K.W.

2.2

2.2

2.3

2.2

2.2

2.2

2.2

2.2

2.2

2.2

2.2

2.2

2.2

2.2

2.3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T.C.

31.9

33.9

34.4

39.0

42.1

33.7

34.9

35.0

39.4

42.4

35.5

35.9

35.5

39.8

42.7

75

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

32.3

30.4

25.4

25.7

20.2

34.1

33.1

27.6

28.0

21.7

35.9

35.8

29.8

30.3

23.2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K.W.

2.5

2.5

2.5

2.5

2.6

2.5

2.5

2.5

2.5

2.6

2.5

2.5

2.5

2.6

2.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T.C.

30.4

32.2

32.4

36.9

40.0

32.0

33.2

32.8

37.2

40.3

33.5

34.3

33.3

37.5

40.6

85

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

30.8

29.5

24.6

24.8

19.6

32.4

32.0

26.7

27.0

21.0

33.9

34.4

28.9

29.3

22.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K.W.

2.8

2.8

2.8

2.9

2.9

2.8

2.8

2.8

2.9

2.9

2.8

2.8

2.9

2.9

2.9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T.C.

29.0

30.4

30.3

34.8

38.0

30.3

31.5

30.6

35.0

38.2

31.6

32.7

31.0

35.2

38.4

95

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

29.3

28.7

23.8

23.9

18.9

30.7

30.8

25.9

26.1

20.3

32.0

33.0

28.0

28.3

21.7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K.W.

3.1

3.1

3.1

3.2

3.2

3.1

3.1

3.2

3.2

3.2

3.1

3.1

3.2

3.2

3.2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T.C.

27.6

28.9

28.2

32.0

35.1

28.7

29.7

28.5

32.2

35.3

29.9

30.6

28.7

32.4

35.5

105

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

27.9

26.8

22.6

22.9

18.0

29.1

28.6

24.7

24.9

19.3

30.2

30.5

26.7

26.9

20.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K.W.

3.6

3.5

3.6

3.6

3.6

3.6

3.6

3.6

3.6

3.6

3.6

3.6

3.6

3.6

3.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T.C.

26.3

27.3

26.2

29.4

32.4

27.2

28.0

26.3

29.5

32.5

28.2

28.7

26.5

29.7

32.6

115

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

26.6

24.9

21.6

21.9

17.1

27.5

26.4

23.5

23.7

18.3

28.5

27.9

25.4

25.5

19.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K.W.

4.0

4.0

4.0

4.1

4.1

4.0

4.0

4.0

4.1

4.1

4.0

4.0

4.0

4.1

4.1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T.C.

24.9

25.8

24.2

26.7

29.6

25.7

26.3

24.2

26.8

29.7

26.5

26.7

24.2

26.9

29.8

125

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

25.2

23.0

20.5

20.9

16.2

26.0

24.2

22.3

22.5

17.3

26.8

25.4

24.1

24.1

18.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K.W.

4.5

4.4

4.4

4.5

4.5

4.5

4.4

4.4

4.5

4.5

4.5

4.5

4.5

4.5

4.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE: ALL CAPACITIES ARE NET (KBTUH) WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.

Multipliers for determining the performance with other indoor sections

NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.

Air Handler

Coil

T.C.

S.C.

KW

MA12B

FC/MC36B

0.98

0.98

1.00

MV16C

FC/MC36C

1.03

1.03

0.96

AHP36

1.00

1.00

1.00

AHP42

1.00

1.00

1.00

AV/SV36

1.02

1.03

0.96

AV/SV48

1.02

1.03

0.96

F2FP036

1.00

1.00

1.00

F2FP042

1.01

1.00

1.00

HC36

1.01

0.98

1.00

HD36

0.99

1.00

1.00

Continued on Page 28.

Johnson Controls Unitary Products

27

Image 27
Contents Listed Model Physical and Electrical DataFootnotes ProceduresCooling Capacity With Air Handler Coils Seer HP with MVVariable Speed FC/MC/PC/UC24 Cooling Capacity YZB01811 With Variable Speed Furnaces Cooling Furnace Model Rated NET MBH Seer EER CFMSens PH 13 Seer HP with Variable Speed Furnaces FC/MC/PC32A Cooling Capacity YZB02411With Variable Speed FurnacesFC/MC/PC37A Cooling Capacity YZB03011With Variable Speed FurnacesCooling Capacity YZB03611With Variable Speed Furnaces UC48C Cooling Capacity YZB04211With Variable Speed Furnaces Cooling Capacity YZB06012With Variable Speed Furnaces Cooling Capacity YZB04811With Variable Speed FurnacesPH 13 Seer HP with AV / SV / F*FV Variable Speed Heating Performance With Air HandlerUnit AIR COIL1 ARI HEATING2 Model Handler PH 13 Seer HP with MV Variable SpeedUnit COIL1 ARI HEATING2 Model Heating Performance Upflow Furnace CoilsFurnace MBH COP STD Seer HP with Variable Speed FURNACES3 Heating Capacity YZB01811With Variable Speed FurnacesVariable COIL1 ARI HEATING2 Speed Model HspfHeating Capacity YZB02411With Variable Speed Furnaces Heating Capacity YZB03011With Variable Speed Furnaces Furnace MBH COP STD Heating Capacity YZB03611With Variable Speed FurnacesLC*C16 HC42 35.4 Heating Capacity YZB04211With Variable Speed Furnaces Heating Capacity YZB06012With Variable Speed Furnaces Heating Capacity YZB04811With Variable Speed FurnacesChoice of Several Color Coil Grilles to Compliment ANY Home AccessoriesCondensing TemperatureAIR Conditioner Model no Indoor Coil Model no FC/MC/PC/UC18Outdoor Unit Model no Indoor Coil Model no AHP24Condenser Indoor Coil Model no FC/MC/PC/UC36 LC*A12 HC30 LC*B12 HC36 9C*B12 HD36 LC*C16 LC*C20 YZB03611 LC*C16 HC42 LC*C20 9C*C16 9C*C20 LC*B12 HD48 Indoor Coil Model no FC/MC/PC/UC48 Indoor Coil Model no FC/MC/PC/UC60 Indoor Coil Model no FC/MC62D Entering Outdoor Unit Indoor CoilMBH COP 800 1000 34.3 35.3 PV8*A12 HD36 PV8*B16 MA12B FC/MC36B MV12B AHP36 AHP42 AV/SV36 AV/SV48 PV8*B16 HC36 HD36 PV8*C16 MA14D FC/MC48D MA16C FC/MC48C MV16C MV20D AHP/SHP48 AV/SV48 1600 1800 Johnson Controls Unitary Products York Drive Norman, OK

YZB018 THRU 060 specifications

The York YZB018 THRU 060 series represents a cutting-edge solution for commercial heating and cooling needs, designed to provide efficient and reliable performance in a variety of applications. These units encompass a range of capacities from 1.5 to 5 tons, making them suitable for different building sizes and requirements. The YZB series is well-known for its robust construction, advanced technology, and exceptional energy efficiency.

One of the main features of the York YZB series is its high-efficiency scroll compressors. These compressors are engineered to deliver superior performance while minimizing energy consumption, thus reducing operational costs for end-users. In addition, the use of environmentally friendly refrigerants helps to comply with modern regulations regarding greenhouse gas emissions, making the YZB series a sustainable choice for businesses.

The YZB series incorporates a user-friendly control system, allowing for simple adjustments to temperature settings and operational modes. This feature enhances user experience and enables better management of indoor climate conditions. The units also come equipped with advanced diagnostic capabilities, which help in identifying potential issues early and optimizing maintenance schedules. This proactive approach extends the lifespan of the equipment while ensuring reliable operation.

Durability is a hallmark of the York YZB series. Constructed with high-quality materials, these units can withstand the rigors of commercial use, including exposure to varying weather conditions. The corrosion-resistant cabinet and robust internal components ensure longevity and performance over time.

Another important characteristic of the YZB series is its quiet operation. With noise levels minimized, these systems are ideal for installations requiring low sound emissions, such as offices, schools, and healthcare facilities.

The flexibility of the YZB series is also noteworthy. The units can be configured for different applications, including rooftop installations, split systems, or even for use in conjunction with ductless systems. This adaptability makes them a versatile option for a wide array of commercial applications.

In summary, the York YZB018 THRU 060 series is distinguished by its energy-efficient performance, robust construction, and advanced technological features. With its user-friendly controls, diagnostic capabilities, and quiet operation, this series is an exemplary choice for businesses aiming for optimal climate management and sustainability in their operations.