York YZB018 THRU 060 Heating Performance Upflow Furnace Coils, Unit COIL1 ARI HEATING2 Model

Page 14

271457-YTG-B-0908

HEATING PERFORMANCE - Upflow Furnace Coils

UNIT

COIL1

 

 

 

ARI HEATING2

 

 

 

MODEL*

MODEL

 

47°F

 

 

 

 

17°F

 

HSPF

 

 

 

 

 

 

 

 

 

 

 

MBH

COP

KW

 

MBH

 

COP

KW

STD

 

 

 

 

 

 

 

 

 

 

 

 

FC/MC/PC/UC18

18.0

3.28

1.61

 

11.6

 

2.32

1.46

8.00

YZB01811

 

 

 

 

 

 

 

 

 

 

HC24

18.0

3.28

1.61

 

11.6

 

2.32

1.46

8.00

 

HD24

18.0

3.28

1.61

 

11.6

 

2.32

1.46

8.00

 

FC/MC/PC/UC24

24.0

3.44

2.04

 

14.2

 

2.38

1.75

8.00

YZB02411

FC/MC/PC/UC30

24.0

3.44

2.04

 

14.2

 

2.38

1.75

8.00

HC30

24.0

3.44

2.04

 

14.2

 

2.38

1.75

8.00

 

 

 

 

HD24

24.0

3.44

2.04

 

14.2

 

2.38

1.75

8.00

 

FC/MC/PC/UC36

30.0

3.44

2.56

 

18.3

 

2.28

2.35

8.00

YZB03011

 

 

 

 

 

 

 

 

 

 

HC36

30.0

3.44

2.56

 

18.3

 

2.28

2.35

8.00

 

HD36

30.0

3.44

2.56

 

18.3

 

2.28

2.35

8.00

 

FC/MC/PC/UC36

36.0

3.36

3.14

 

24.4

 

2.32

3.08

8.00

YZB03611

 

 

 

 

 

 

 

 

 

 

HC36

36.0

3.36

3.14

 

24.4

 

2.32

3.08

8.00

 

HD36

36.0

3.36

3.14

 

24.4

 

2.32

3.08

8.00

 

FC/MC/PC/UC48

42.0

3.66

3.36

 

28.4

 

2.54

3.28

8.00

YZB04211

 

 

 

 

 

 

 

 

 

 

HC48

42.0

3.66

3.36

 

28.4

 

2.54

3.28

8.00

 

HD48

42.0

3.66

3.36

 

28.4

 

2.54

3.28

8.00

 

FC/MC/PC/UC60

48.0

3.50

4.10

 

33.2

 

2.30

4.23

8.00

YZB04811

HC60

48.0

3.50

4.10

 

33.2

 

2.30

4.23

8.00

HD60

48.0

3.50

4.10

 

33.2

 

2.30

4.23

8.00

 

 

 

 

MC61

48.0

3.50

4.10

 

33.2

 

2.30

4.23

8.00

YZB06012

FC/MC62D

57.0

3.54

4.77

 

37.0

 

2.44

4.49

8.55

1.Rated CFM same as for cooling.

2.Heating MBH based on ARI standards of 70° DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and no supplemental electric heat operation.

CP equals MBH output divided by (total KW input x 3.412).

HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the total electric power input during the same period.

— = Not Applicable.

14

Johnson Controls Unitary Products

Image 14
Contents Listed Physical and Electrical Data ModelProcedures FootnotesVariable Speed Cooling Capacity With Air Handler CoilsSeer HP with MV FC/MC/PC/UC24 Sens PH 13 Seer HP with Variable Speed Furnaces Cooling Capacity YZB01811 With Variable Speed FurnacesCooling Furnace Model Rated NET MBH Seer EER CFM Cooling Capacity YZB02411With Variable Speed Furnaces FC/MC/PC32ACooling Capacity YZB03011With Variable Speed Furnaces FC/MC/PC37ACooling Capacity YZB03611With Variable Speed Furnaces UC48C Cooling Capacity YZB04211With Variable Speed Furnaces Cooling Capacity YZB04811With Variable Speed Furnaces Cooling Capacity YZB06012With Variable Speed FurnacesPH 13 Seer HP with MV Variable Speed Heating Performance With Air HandlerUnit AIR COIL1 ARI HEATING2 Model Handler PH 13 Seer HP with AV / SV / F*FV Variable SpeedHeating Performance Upflow Furnace Coils Unit COIL1 ARI HEATING2 ModelHspf Heating Capacity YZB01811With Variable Speed FurnacesVariable COIL1 ARI HEATING2 Speed Model Furnace MBH COP STD Seer HP with Variable Speed FURNACES3Heating Capacity YZB02411With Variable Speed Furnaces Heating Capacity YZB03011With Variable Speed Furnaces Heating Capacity YZB03611With Variable Speed Furnaces Furnace MBH COP STDLC*C16 HC42 35.4 Heating Capacity YZB04211With Variable Speed Furnaces Heating Capacity YZB04811With Variable Speed Furnaces Heating Capacity YZB06012With Variable Speed FurnacesAccessories Choice of Several Color Coil Grilles to Compliment ANY HomeIndoor Coil Model no FC/MC/PC/UC18 TemperatureAIR Conditioner Model no CondensingCondenser Outdoor Unit Model noIndoor Coil Model no AHP24 Indoor Coil Model no FC/MC/PC/UC36 LC*A12 HC30 LC*B12 HC36 9C*B12 HD36 LC*C16 LC*C20 YZB03611 LC*C16 HC42 LC*C20 9C*C16 9C*C20 LC*B12 HD48 Indoor Coil Model no FC/MC/PC/UC48 Indoor Coil Model no FC/MC/PC/UC60 Indoor Coil Model no FC/MC62D MBH COP EnteringOutdoor Unit Indoor Coil 800 1000 34.3 35.3 PV8*A12 HD36 PV8*B16 MA12B FC/MC36B MV12B AHP36 AHP42 AV/SV36 AV/SV48 PV8*B16 HC36 HD36 PV8*C16 MA14D FC/MC48D MA16C FC/MC48C MV16C MV20D AHP/SHP48 AV/SV48 1600 1800 Johnson Controls Unitary Products York Drive Norman, OK

YZB018 THRU 060 specifications

The York YZB018 THRU 060 series represents a cutting-edge solution for commercial heating and cooling needs, designed to provide efficient and reliable performance in a variety of applications. These units encompass a range of capacities from 1.5 to 5 tons, making them suitable for different building sizes and requirements. The YZB series is well-known for its robust construction, advanced technology, and exceptional energy efficiency.

One of the main features of the York YZB series is its high-efficiency scroll compressors. These compressors are engineered to deliver superior performance while minimizing energy consumption, thus reducing operational costs for end-users. In addition, the use of environmentally friendly refrigerants helps to comply with modern regulations regarding greenhouse gas emissions, making the YZB series a sustainable choice for businesses.

The YZB series incorporates a user-friendly control system, allowing for simple adjustments to temperature settings and operational modes. This feature enhances user experience and enables better management of indoor climate conditions. The units also come equipped with advanced diagnostic capabilities, which help in identifying potential issues early and optimizing maintenance schedules. This proactive approach extends the lifespan of the equipment while ensuring reliable operation.

Durability is a hallmark of the York YZB series. Constructed with high-quality materials, these units can withstand the rigors of commercial use, including exposure to varying weather conditions. The corrosion-resistant cabinet and robust internal components ensure longevity and performance over time.

Another important characteristic of the YZB series is its quiet operation. With noise levels minimized, these systems are ideal for installations requiring low sound emissions, such as offices, schools, and healthcare facilities.

The flexibility of the YZB series is also noteworthy. The units can be configured for different applications, including rooftop installations, split systems, or even for use in conjunction with ductless systems. This adaptability makes them a versatile option for a wide array of commercial applications.

In summary, the York YZB018 THRU 060 series is distinguished by its energy-efficient performance, robust construction, and advanced technological features. With its user-friendly controls, diagnostic capabilities, and quiet operation, this series is an exemplary choice for businesses aiming for optimal climate management and sustainability in their operations.