CABINET AND DUCT DIMENSIONS
Models | CFM | CABINET |
| CABINET DIMENSION |
| |||
SIZE | A (IN.) | B (IN.) | C (IN.) | D (IN.) | E (IN.) | |||
|
| |||||||
PT9B12N060DH11 | 1200 | B | 15 | |||||
PT9B12N080DH11 | 1200 | B | 15 | |||||
PT9C16N080DH11 | 1600 | C | 21 | |||||
PT9C20N100DH11 | 2000 | C | 21 | |||||
PT9D20N120DH11 | 2000 | D | 22 | 3 |
ELECTRICAL AND PERFORMANCE DATA
| Input | Output | Nominal | Cabinet | Total Unit | AFUE | Air Temp. | |||
Models | (High/Low) | (High/Low) | Airflow | Width | Rise | |||||
|
| |||||||||
|
|
|
|
|
|
|
|
| ||
| MBH | MBH |
| CFM | In. | Amps | % | °F | ||
PT9B12N060DH11 | 60 / 39 | 56 / 36 |
| 1200 | 9 | 92 | 35 - 65 | |||
PT9B12N080DH11 | 80 / 52 | 75 / 49 |
| 1200 | 9 | 92 | 35 - 65 | |||
PT9C16N080DH11 | 80 / 52 | 75 / 49 |
| 1600 | 21 | 12 | 92 | 35 - 65 | ||
PT9C20N100DH11 | 100 / 65 | 93 / 61 |
| 2000 | 21 | 14 | 92 | 35 - 65 | ||
PT9D20N120DH11 | 120 / 78 | 112 / 74 |
| 2000 | 14 | 92 | 35 - 65 | |||
|
|
|
|
|
|
|
|
|
| |
| Input | Max. Outlet | Blower | Blower | Max. | Min. Wire Size | Operating | |||
Models | (High/Low) | Air Temp. | Size | (awg) @ 75 ft. | Weight | |||||
|
|
| ||||||||
|
|
|
|
|
|
| Protect | One Way |
| |
| MBH | °F | HP |
| Amps | In. | Lbs. | |||
PT9B12N060DH11 | 60 / 39 | 165 | 1/2 |
| 7.0 | 11 x 8 | 20 | 14 | 136 | |
PT9B12N080DH11 | 80 / 52 | 165 | 1/2 |
| 7.0 | 11 x 8 | 20 | 14 | 143 | |
PT9C16N080DH11 | 80 / 52 | 165 | 3/4 |
| 10.2 | 11 x 10 | 20 | 14 | 159 | |
PT9C20N100DH11 | 100 / 65 | 165 | 1 |
| 12.7 | 11 x 11 | 20 | 12 | 164 | |
PT9D20N120DH11 | 120 / 78 | 165 | 1 |
| 12.7 | 11 x 11 | 20 | 12 | 182 |
Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures.
Wire size and over current protection must comply with the National Electrical Code
*Wire size and overcurrent protection must comply with the National Electric Code.
NOTES:
1.For altitudes above 2000 ft. reduce capacity 4% for each 1000 ft. above sea level.
2.Wire size based on copper conductors, 60°C, 3% voltage drop.
3.Continuous return air temperature must not be below 55°F.
4.All filters must be high velocity cleanable type.