York H*RA018 THRU 060, H*RA036 THRU 090 Cooling Performance Data, Phase, Air Conditioner Model No

Page 14
Manual background

036-21121-002 Rev. A (0602)

COOLING PERFORMANCE DATA

AIR CONDITIONER MODEL NO.

H1RA048S06, H1RA048S(25,46)

 

 

 

 

 

 

 

INDOOR COIL MODEL NO.

 

G1FA048S21,24

 

 

 

 

 

 

 

 

 

CONDENSER

ID CFM

 

1200

 

 

1400

 

 

1600

 

ENTERING AIR

ID DB (°F)

85

80

75

70

85

80

75

70

85

80

75

70

TEMPERATURE

 

 

 

 

 

 

 

 

 

 

 

 

 

ID WB (°F)

72

67

62

57

72

67

62

57

72

67

62

57

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T.C.

53.4

48.9

45.1

40.2

54.3

49.8

45.9

41.3

54.9

50.3

46.4

41.8

75

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

32.2

32.3

31.0

32.5

34.0

34.0

32.7

34.7

35.2

35.3

33.9

35.9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K.W

4.32

4.15

4.00

3.83

4.44

4.26

4.11

3.95

4.53

4.36

4.21

4.04

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T.C.

52.0

47.5

43.7

39.2

52.7

48.3

44.5

40.0

53.2

48.7

45.2

40.5

85

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

32.2

32.3

31.1

32.7

34.1

34.1

32.8

34.7

35.4

35.5

34.5

36.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K.W

4.62

4.43

4.26

4.07

4.74

4.55

4.38

4.18

4.84

4.65

4.48

4.28

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T.C.

49.0

44.9

41.3

36.9

49.6

45.5

42.0

37.6

50.0

45.8

42.4

38.3

95

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

31.6

31.6

30.4

31.8

33.5

33.7

32.4

33.8

34.9

35.0

33.7

35.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K.W

4.91

4.70

4.51

4.31

5.02

4.81

4.64

4.43

5.13

4.92

4.74

4.53

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T.C.

45.6

41.6

38.4

34.3

46.0

42.2

39.0

35.0

46.2

42.5

39.3

36.2

105

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

30.5

30.6

29.5

30.9

32.6

32.8

31.5

32.8

34.1

34.2

32.7

34.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K.W

5.18

4.96

4.76

4.54

5.30

5.07

4.88

4.67

5.39

5.18

4.99

4.83

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T.C.

41.8

38.3

35.3

31.7

42.3

38.8

35.8

33.0

42.5

39.0

36.2

33.5

115

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

29.3

29.5

28.2

29.6

31.6

31.4

30.1

31.5

33.0

32.9

31.5

32.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K.W

5.42

5.18

4.98

4.76

5.52

5.31

5.10

4.94

5.63

5.41

5.21

5.06

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T.C.

38.0

35.0

32.3

29.1

38.6

35.4

32.7

31.0

38.8

35.5

33.2

30.8

125

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

28.1

28.4

26.9

28.3

30.6

30.0

28.7

30.2

31.9

31.6

30.4

29.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K.W

5.66

5.40

5.20

4.98

5.74

5.55

5.32

5.21

5.87

5.64

5.43

5.29

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.

Multipliers for determining the performance with other indoor sections.

1 Phase

 

 

 

 

Air Handler

Coil

T.C.

S.C.

KW

N1AHC1606

G2FD048S21

1.01

1.01

1.01

 

 

 

 

 

N1AHD2006

G2FD060S24

1.03

1.03

1.01

 

 

 

 

 

F2FP048

 

1.00

1.00

1.03

 

 

 

 

 

F2FP060

 

1.02

1.02

1.00

 

 

 

 

 

 

G1FA048S17

0.98

0.99

1.01

 

 

 

 

 

 

G1FA060S21,24

1.03

1.03

1.01

 

 

 

 

 

 

G1HD048

1.00

1.00

0.99

 

 

 

 

 

 

G1HD060

1.02

1.02

1.00

 

 

 

 

 

3 Phase

Air Handler

Coil

T.C.

S.C.

KW

N1AHC1646

G2FD048S21

1.01

1.01

1.00

 

 

 

 

 

N1AHD2046

G2FD048S24

1.01

1.01

1.00

 

 

 

 

 

N1AHD2046

G2FD060S24

1.03

1.03

1.00

 

 

 

 

 

F2FP048

 

1.00

1.00

1.03

 

 

 

 

 

 

G1FA048S21,24

1.00

1.00

1.00

 

 

 

 

 

 

G1NA048S21D

1.02

1.02

1.02

 

 

 

 

 

 

G1UA048S21,24

1.00

1.00

1.00

 

 

 

 

 

 

G2FD048S21,24

1.01

1.01

1.01

 

 

 

 

 

14

Unitary Products Group

Image 14
Contents DESCRIPTION WARRANTYFEATURES Single Phase UnitsMODEL Physical and Electrical Data - 1 PhasePhysical and Electrical Data - 3 Phase MODELUnitary Products Group COOLING CAPACITY - With Air Handler Coils036-21121-002Rev. A 036-21121-002Rev. A 036-21121-002Rev. A Unitary Products GroupCOOLING PERFORMANCE DIMENSIONS - 1 PhaseDIMENSIONS - 3 Phase 036-21121-002Rev. ASOUND RATINGS ACCESSORIESTYPICAL INSTALLATION NOTE ALL OUTDOOR WIRING MUST BE WEATHERPROOFTYPICAL FIELD WIRING - 1 Phase Application TYPICAL FIELD WIRING - 3 Phase ApplicationCOOLING PERFORMANCE DATA COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NOH2RA030S06 COOLING PERFORMANCE DATAAIR CONDITIONER MODEL NO INDOOR COIL MODEL NO3 Phase COOLING PERFORMANCE DATAAIR CONDITIONER MODEL NO 3 PhaseCOOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO 3 PhaseCOOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO COOLING PERFORMANCE DATA036-21121-002Rev. A H3RA060S06H1RA060S25,46 COOLING PERFORMANCE DATAAIR CONDITIONER MODEL NO INDOOR COIL MODEL NOAIR CONDITIONER MODEL NO COOLING PERFORMANCE DATA036-21121-002Rev. A H1RA076S25,46H1RA090S25,46 COOLING PERFORMANCE DATAAIR CONDITIONER MODEL NO INDOOR COIL MODEL NOAIR HANDLERS - FOR NON-FURNACEAPPLICATIONS MATCHING INDOOR COMPONENTSADD-ONCOILS - FOR FURNACE APPLICATIONS Norman Unitary5005 Products