York DNP048, DNP060, DNP030, DNP024, DNP042, DNP036 warranty Power Wiring Field Diagram Electrical Data

Page 19

036-21366-007-A-1205

CONTACTOR

FIELD-SUPPLIED

DISCONNECT

SINGLE

PHASE

POWER

GROUND REFERTOELECTRICAL SUPPLY LUG DATATABLESTOSIZE

THEDISCONNECT

 

CONTACTOR

 

 

FIELD-SUPPLIED

 

 

DISCONNECT

 

 

 

THREE

 

 

PHASE

GROUND

POWER

 

LUG

REFERTOELECTRICAL

SUPPLY

 

DATATABLESTOSIZE

THEDISCONNECT

FIGURE 4 - POWER WIRING FIELD DIAGRAM

TABLE 14: ELECTRICAL DATA

 

 

VOLTAGE

COMPRESSOR

COND.

SUPPLY

 

MAX.

MAX.

 

 

MODEL

 

LIMITATIONS1

AIR

MINIMUM

HACR

UNIT

TRANSFORMER

 

 

 

FAN

FUSE

DNP

POWER SUPPLY

 

 

 

 

MOTOR,

BLOWER

CIRCUIT

SIZE,

BREAKER

POWER

SIZE (VA)

 

MIN.

MAX.

RLA

LRA

MOTOR

AMPACITY

SIZE,

FACTOR

 

 

FLA

AMPS2

 

 

 

FLA

 

AMPS

 

 

 

 

 

 

 

 

 

 

 

 

 

024

208/230-1-60

187

253

8.0

53.5

1.1

2.6

16.5

20

20

0.96

40

030

208/230-1-60

187

253

13.6

67

1.1

6.8

24.9

35

35

0.96

40

030

208/230-3-60

187

253

8.6

55

1.1

6.8

18.7

25

25

0.96

75

030

460-3-60

432

504

5.7

39

0.6

6.8

13.4

20

20

0.96

75

036

208/230-1-60

187

253

17.2

88

1.1

6.8

29.4

45

45

0.96

40

036

208/230-3-60

187

253

11.4

77

1.1

6.8

22.2

30

30

0.96

75

036

460-3-60

432

504

5.7

39

0.6

6.8

14.8

20

20

0.96

75

 

 

 

 

 

 

 

 

 

 

 

 

 

036

575-3-60

540

630

4.7

31

0.6

6.8

13.3

20

20

0.96

75

042

208/230-1-60

187

253

20

104

1.3

9.1

35.4

50

50

0.96

40

042

208/230-3-60

187

253

13.9

88

1.3

9.1

27.8

40

40

0.96

75

 

 

 

 

 

 

 

 

 

 

 

 

 

042

460-3-60

432

504

6.4

44

0.7

9.1

18.5

25

25

0.96

75

 

 

 

 

 

 

 

 

 

 

 

 

 

042

575-3-60

540

630

5.4

34

0.6

9.1

16.8

25

25

0.96

75

048

208/230-1-60

187

253

23.4

126

1.9

9.1

39.5

60

60

0.96

40

048

208/230-3-60

187

253

13

93

1.9

9.1

26.5

35

35

0.96

75

 

 

 

 

 

 

 

 

 

 

 

 

 

048

460-3-60

432

504

6.4

46.5

1.0

9.1

18.4

25

25

0.96

75

048

575-3-60

540

630

5.1

37.2

0.8

9.1

17.3

25

25

0.96

75

060

208/230-1-60

187

253

25

150

2.8

9.1

43.2

60

60

0.96

40

060

208/230-3-60

187

253

17.3

123

2.8

9.1

33.5

45

45

0.96

75

060

460-3-60

432

504

8.4

70

2.8

9.1

22.6

30

30

0.96

75

 

 

 

 

 

 

 

 

 

 

 

 

 

060

575-3-60

540

630

7.0

53

2.8

9.1

21.2

30

30

0.96

75

1.Rated in accordance with ARI Standard 110, utilization range “A”.

2.Dual element, time delay type.

Unitary Products Group

19

Image 19
Contents Featuring DescriptionTable of Contents Standard FEATURES/BENEFITS FIELD-INSTALLED Accessories 036-21366-007-A-1205 Model DNP Unit Component Location Physical DataMBH Burners Range Ratings COOLING/GAS HeatingEvaporator Temperature of AIR on Condenser CoilNET Power Sensible CAPACITY1 DNP024 Cooling Capacities 2 TONDNP024 Cooling Capacities 2 TON CONT’D AIR on Temperature of AIR on Condenser CoilDNP030 Cooling Capacities 2-1/2 TON Temperature AIR on Evaporator CoilAIR on WB F AIR on DNP036 Cooling Capacities 3 TONCondenser Coil DNP042 Cooling Capacities 3-1/2 TON DNP048 Cooling Capacities 4 TON WB F Condenser Coil DNP060 Cooling Capacities 5 TONSPD TWO TON AIR PerformanceSide Supply AIR Blower Performance 208/230 VOLTS1 Bottom Supply AIR Blower Performance 208/230 VOLTS1 WET Evaporator Coil ECONOMIZER1 Filter Frame KIT Additional Static Pressure Resistance 2, 2-1/2, 3 TONAdditional Static Pressure Resistance 3-1/2, 4 and 5 TON RESISTANCE, IWGPower Wiring Field Diagram Electrical Data Unit Minimum CLEARANCES1 Unit Dimensions FrontKnockout Typical Slab on Ground Installation Size WeightUnit Shipping Operating Economizer RoofRoof Curb DIMENSIONS1 Typical Wiring Diagram D*NP 024 208/230-1-60 Power Supply Power Supply Typical Wiring Diagram D*NPTypical Wiring Diagram D*NP 060 208/230-1-60 Power Supply Wiring Typical Wiring Diagram D*NP 060 208/230-3-60 Power Supply Unitary Products Group Typical Wiring Diagram D*NP 060 460/575-3-60 Power Supply Typical Wiring Diagram Notes Description GeneralUnit Operating Characteristics 036-21366-007-A-1205 036-21366-007-A-1205