TABLE 10: SIDE SUPPLY AIR PERFORMANCE - 208 VOLT1

MODEL #

 

 

 

 

 

 

 

 

 

 

 

 

 

EXTERNAL STAIC PRESSURE - IWG

 

 

 

 

 

 

 

 

 

 

 

.10

 

.20

 

.30

 

.40

 

.50

 

.60

 

.70

 

.80

 

.90

 

1.00

1.10

DNH

MTR

 

 

 

 

 

 

 

 

 

CFM

 

WATTS

CFM

 

WATTS

CFM

 

WATTS

CFM

 

WATTS

CFM

 

WATTS

CFM

 

WATTS

CFM

 

WATTS

CFM

 

WATTS

CFM

 

WATTS

CFM

WATTS

CFM

WATTS

(Cooling/

SPD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Heating)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HI

-

 

-

-

 

-

-

 

-

-

 

-

-

 

-

-

 

-

-

 

-

-

 

-

608

 

358

465

326

-

-

018

MED

-

 

-

-

 

-

-

 

-

-

 

-

-

 

-

695

 

263

615

 

246

509

 

226

-

 

-

-

-

-

-

 

LOW

743

 

243

700

 

235

657

 

226

614

 

218

549

 

207

483

 

195

-

 

-

-

 

-

-

 

-

-

-

-

-

 

HI

-

 

-

-

 

-

-

 

-

-

 

-

-

 

-

984

 

443

894

 

422

751

 

390

608

 

358

-

-

-

-

024

MED

994

 

333

947

 

321

901

 

309

854

 

297

774

 

280

695

 

263

615

 

246

-

 

-

-

 

-

-

-

-

-

 

LOW

743

 

243

700

 

235

657

 

226

614

 

218

-

 

-

-

 

-

-

 

-

-

 

-

-

 

-

-

-

-

-

 

HI

-

 

-

-

 

-

1238

 

504

1165

 

484

1075

 

463

984

 

443

894

 

422

751

 

390

-

 

-

-

-

-

-

030

MED

994

 

333

947

 

321

901

 

309

854

 

297

774

 

280

-

 

-

-

 

-

-

 

-

-

 

-

-

-

-

-

 

LOW

-

 

-

-

 

-

-

 

-

-

 

-

-

 

-

-

 

-

-

 

-

-

 

-

-

 

-

-

-

-

-

 

HI

-

 

-

-

 

-

-

 

-

-

 

-

1465

 

712

1390

 

685

1315

 

657

1204

 

623

1093

 

588

982

554

-

-

036

MED

1432

 

650

1381

 

628

1330

 

605

1279

 

583

1210

 

556

1140

 

529

1071

 

502

977

 

477

-

 

-

-

-

-

-

 

LOW

1191

 

527

1149

 

510

1107

 

494

1065

 

477

1009

 

459

952

 

441

-

 

-

-

 

-

-

 

-

-

-

-

-

 

HI

-

 

-

1681

 

797

1610

 

768

1540

 

740

1465

 

712

1390

 

685

1315

 

657

1204

 

623

1093

 

588

-

-

-

-

042

MED

1432

 

650

1381

 

628

1330

 

605

1279

 

583

1210

 

556

1140

 

529

-

 

-

-

 

-

-

 

-

-

-

-

-

 

LOW

1191

 

527

1149

 

510

1107

 

494

1065

 

477

-

 

-

-

 

-

-

 

-

-

 

-

-

 

-

-

-

-

-

 

HI

1742

 

898

1695

 

869

1648

 

841

1601

 

811

1555

 

781

1501

 

747

1446

 

714

1317

 

667

-

 

-

-

-

-

-

048

MED

1523

 

750

1498

 

730

1473

 

710

1447

 

692

1421

 

673

1371

 

647

1320

 

620

1211

 

580

-

 

-

-

-

-

-

 

LOW

1343

 

620

1327

 

606

1310

 

593

1280

 

573

1250

 

553

-

 

-

-

 

-

-

 

-

-

 

-

-

-

-

-

060

HEAT

1500

 

245

1500

 

297

1500

 

348

1500

 

400

1500

 

470

1500

 

540

1500

 

610

1500

 

680

1500

 

750

1500

820

1500

890

(3 tube)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

060

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(4 & 5

HEAT

1700

 

390

1700

 

443

1700

 

497

1700

 

550

1700

 

620

1700

 

690

1700

 

760

1700

 

830

1700

 

900

-

-

-

-

tube)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

060

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(factory

COOL

1800

 

460

1800

 

515

1800

 

570

1800

 

625

1800

 

690

1800

 

755

1800

 

820

1800

 

962

-

 

-

-

-

-

-

setting)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

060

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(field

COOL

2000

 

640

2000

 

700

2000

 

760

2000

 

820

2000

 

928

-

 

-

-

 

-

-

 

-

-

 

-

-

-

-

-

setting)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.Above data includes allowances for a dry evaporator coil, gas heat exchanger and no filters. For additional pressure drops, refer to Table 14 and 15.

Unitary Products Group

15

Image 15
Contents Flexible Light Commercial Unit GeneralFeaturing Table of Contents Description Standard FEATURES/BENEFITSHigh Altitude Conversion KIT Natural Gas/Propane FIELD-INSTALLED AccessoriesCoilguard Model DNH Physical DataAfue Rise MBH Burners Range Ratings COOLING/GAS HeatingTemperature AIR on Evaporator Coil DNH018 Cooling Capacities 1-1/2 TONAIR on WB F DNH024 Cooling Capacities 2 TON AIR on DNH030 Cooling Capacities 2-1/2 TONDNH036 Cooling Capacities 3 TON DNH042 Cooling Capacities 3-1/2 TON DNH048 Cooling Capacities 4 TON DNH060 Cooling Capacities 5 TON SPD Side Supply AIR Performance 208 VOLT1Model # External Staic Pressure IWG MTRModel # External Static Pressure IWG Side Supply AIR Blower Performance 230, 460 & 575 VOLT1Bottom Supply AIR Blower Performance 208 VOLT1 Additional Static Pressure Resistance 1-1/2 3 TON DNH018 Bottom Supply AIR Blower Performance 230, 460 & 575 VOLTS1WET Evaporator Coil ECONOMIZER2 Filter Frame KIT Additional Static Pressure Resistance 3-1/2 5 TON DNH042Electrical Data Supply Motor BlowerFactor FLA Amps Unit Size Dimension Unit Minimum CLEARANCES1Clearances Unit Dimensions Front & Bottom Typical Slab on Ground Installation 133 Roof Curb DIMENSIONS1 Cchpconfigurationblk L12 Typical Wiring Diagram 460-3-60 Power Supply Typical Wiring Diagram LEGEND1 Typical Wiring Diagram NotesDescription Mechanical SpecificationsRefrigerant Components 036-21233-002-A-0903 036-21233-002-A-0903

DNH018 specifications

The York DNH018 is a highly efficient ductless mini-split heat pump system well-regarded in the HVAC industry for its innovative features and impressive performance. This unit is designed to provide both heating and cooling, making it a versatile choice for a variety of residential and light commercial applications.

One of the main features of the York DNH018 is its energy efficiency. With a Seasonal Energy Efficiency Ratio (SEER) rating that exceeds many traditional systems, this mini-split model serves to reduce energy consumption and lower utility bills. Its high efficiency is complemented by an impressive Heating Seasonal Performance Factor (HSPF), which ensures optimal performance even in colder climates.

The technology behind the York DNH018 is cutting-edge. It utilizes inverter technology that allows the compressor to adjust its speed according to the heating or cooling demand. This results in a more consistent temperature and improved comfort levels. Inverter systems provide quieter operation and enhance the lifespan of the equipment by reducing wear and tear compared to traditional systems that constantly turn on and off.

Another characteristic of the York DNH018 is its compact and sleek design. The outdoor unit is designed to take minimal space while still delivering powerful performance. The indoor unit is available in various styles, including wall-mounted and ceiling cassettes, allowing for flexible installation options that can blend seamlessly into a variety of room aesthetics.

The system also includes advanced filtration technology that helps improve indoor air quality by reducing allergens and contaminants in the air. Many models come with a multi-stage filter system that captures dust, pollen, and other particles, promoting a healthier living environment.

Moreover, the York DNH018 offers user-friendly controls. Many units come equipped with programmable thermostats and remote control options, enabling users to manage their indoor climate efficiently. Some models even feature Wi-Fi connectivity, allowing for smartphone integration for remote temperature management.