York TM9V warranty Cabinet & Duct Dimensions, Ratings & Physical / Electrical Data, Afue, Mbh

Page 2

444555-YTG-A-0209

LEFT SIDE

 

Combustion Air Inlet

 

Condensate Drain

Gas Pipe

(Downflow)

Entry

Vent Outlet

Electrical

 

Entry

 

Condensate

 

Drain

 

Thermostat

 

Wiring

28.5”

 

29.5”

 

.56”

 

23.8”

3”

FRONT

A

 

 

RIGHT SIDE

 

 

 

Combustion Air Inlet

 

 

Gas Pipe

Condensate Drain

 

 

Entry

(Downflow)

 

 

Electrical

 

 

 

Entry

Vent Outlet

 

33

Condensate

23”

 

 

Drain

 

 

 

 

 

Thermostat

Optional Return Air

 

 

Wiring

14”

 

Cutout (Either side)

 

 

 

 

 

 

 

 

1”

 

 

1.5”

 

Vent

Outlet

BCombustion

Air Inlet

C

 

.56”

 

 

 

.56”

 

 

 

 

 

 

 

20”

 

 

 

 

 

SUPPLY END

B

24.25”

RETURN END

Cabinet & Duct Dimensions

 

Nominal

Cabinet

Cabinet Dimensions (Inches)

Approximate

Model

Operating Weights

CFM (m3/min)

Size

 

 

 

 

A

B

C

Lbs

 

 

 

 

 

 

 

 

 

 

TM9V060B12MP11

1200

B

17 1/2

16 3/8

13 1/4

122

 

 

 

 

 

 

 

TM9V080B12MP11

1200

B

17 1/2

16 3/8

13 1/4

126

 

 

 

 

 

 

 

TM9V080C16MP11

1600

C

21

19 7/8

16 1/2

136

 

 

 

 

 

 

 

TM9V100C16MP11

1600

C

21

19 7/8

18 1/4

142

 

 

 

 

 

 

 

TM9V100C20MP11

2000

C

21

19 7/8

18 1/4

145

 

 

 

 

 

 

 

TM9V120D20MP11

2000

D

24 1/2

23 3/8

21 3/4

156

 

 

 

 

 

 

 

Ratings & Physical / Electrical Data

 

Input

Output

 

Total

AFUE

High Fire

Low Fire

Model

High/Low

High/Low

 

Unit

Air Temp. Rise

Air Temp. Rise

 

 

 

MBH

MBH

 

Amps

%

°F

°F

 

 

 

 

 

 

 

 

TM9V060B12MP11

60/39

58/37

 

9

96

35 - 65

35 - 65

 

 

 

 

 

 

 

 

TM9V080B12MP11

80/52

77/50

 

9

96

35 - 65

30 - 60

 

 

 

 

 

 

 

 

TM9V080C16MP11

80/52

77/50

 

12

96

35 - 65

35 - 65

 

 

 

 

 

 

 

 

TM9V100C16MP11

100/65

96/62

 

12

96

35 - 65

30 - 65

 

 

 

 

 

 

 

 

TM9V100C20MP11

100/65

96/62

 

14

96

35 - 65

35 - 65

 

 

 

 

 

 

 

 

TM9V120D20MP11

120/78

115/75

 

14

96

35 - 65

35 - 65

 

 

 

 

 

 

 

 

 

Max. Outlet

 

Blower

Blower Size

Max.

Min. Wire Size

Model

Air Temp.

 

Over-current

(awg) @ 75 ft.

 

 

 

 

 

 

 

 

 

 

Protect

One Way

 

°F

HP

 

Amps

In.

 

 

 

 

 

 

 

 

TM9V060B12MP11

170

1/2

 

7

11 x 8

15

14

TM9V080B12MP11

175

1/2

 

7

11 x 8

15

14

TM9V080C16MP11

175

3/4

 

10.2

11 x 10

15

14

TM9V100C16MP11

175

3/4

 

10.2

11 x 10

15

14

TM9V100C20MP11

175

1

 

12.7

11 x 11

20

12

TM9V120D20MP11

170

1

 

12.7

11 x 11

20

12

Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures.

Wire size and over current protection must comply with the National Electrical Code (NFPA-70-latest edition) and all local codes. The furnace shall be installed so that the electrical components are protected from water.

2

Johnson Controls Unitary Products

Image 2